Low temperature biochemical incubator (-10 ℃ -65 ℃)
Low temperature biochemical incubator is a high-precision constant temperature cultivation equipment with cold and hot control, which can be used for
Product details

1Low temperature biochemical incubatorIntroduction:
Low temperature biochemical incubatorIt is a high-precision constant temperature cultivation equipment with cold and hot control, which can be used for plant cultivation, breeding experiments, cultivation and preservation of bacteria, molds, and microorganisms, BOD determination for water analysis, and other purposes of constant temperature experiments. It is an ideal experimental equipment for research institutions such as biological genetic engineering, medical, health and epidemic prevention, drug testing, agriculture, animal husbandry, and aquatic products.
IILow temperature biochemical incubatorStructural characteristics
This chassis body is made of high-quality thin plate processing, and the surface is treated with electrostatic spraying technology, which has the characteristics of corrosion resistance and not easy rusting. The interior is made of mirror stainless steel, which is easy to clean and beautiful.
The temperature control system adopts a new intelligent LCD temperature regulator with microcomputer microcontroller technology. Users can set and adjust the temperature and time according to different requirements by operating the touch keys on the control panel to achieve the test objectives.
Equipped with a printer or RS485 interface, capable of recording changes in temperature parameters. (Optional during procurement)

It has over temperature alarm and over temperature protection functions.
IIILow temperature biochemical incubatorTechnical parameters:
PRODUCT MODEL
SPX-150A
SPX-250A
SPX-300A
control mode
Balanced/gap type
Temperature Control Range
-10℃~+65℃
Temperature display accuracy
0.1℃
precision
± 0.1 ℃ (at 45 ℃)
temperature uniformity
± 1 ℃ (at 45 ℃)
Ambient Temperature
5~35
Dimensions (mm)
W625*D657*H1270
W620*D600*H1650
W620*D600*H1780
Inner container size (mm)
W500*D450*H67
W520*D470*H1100
W520*D470*H1230
Product weight
Approximately 95.5KG
About 117KG
About 130KG
effective volume
150L
250L
300L
Temperature control method
Fuzzy logic PID control method
supply voltage
AC-220V 50/60HZ
program control
Normal mode/Program mode
Cooling Power
230W
260W
350W
Power
400W
450W
500W
test hole
Double testing holes on both sides
Tray (standard)
three layers
four layers
four layers
4Low temperature biochemical incubatorInstallation and debugging:
1. This device needs to be installed in a well ventilated and dry room away from direct sunlight, with a distance of at least 15CM between the device and the wall.
When placing the box, it must be placed steadily.
3. This device uses AC 220V/50Hz power supply, and there must be a reliable grounding wire in the power supply circuit to ensure safe use.
5Low temperature biochemical incubatorUsage
1. Connect the power supply, turn on the power switch, make the switch in the "on" position, and the device enters the power on state. At this point, the temperature and time setting operation can begin
1) Temperature setting: Click the function key, and the upper row of the display screen will show sp, while the lower row will show the set temperature. At this point, click the up and down buttons to select the set temperature.
2) Time setting: After setting the temperature, click the function key again. At this time, the upper row displays' st 'and the lower row displays the constant temperature timing time. At the same time, the hour two digits in the setting time bar start flashing. Adjust the up and down keys to select the hour time for constant temperature timing. After setting, click the function key again, and the minute position starts flashing. Click the up or down key to select the minute time. Once selected, click the function key again to exit the setting state. The temperature and time will start running according to the set program. If timing is not required, the time can be set to 0, and the temperature will continue to operate at this time.
Timer function: After the instrument enters a constant temperature state, the timer function starts to activate. After the timer ends, the output is turned off. The heater and refrigeration compressor stop working, and the buzzer sounds. The temperature inside the incubator will gradually reach the ambient temperature.
3. Status indication: After the setting is completed, the device runs according to the set parameters. When the measured temperature is lower than the set temperature, the device enters the heating state and the heating indicator light is on. On the contrary, when the measured temperature is higher than the set temperature, the cooling indicator light will turn on and the equipment will enter the cooling state. When the measured temperature is 2 ℃ higher than the set temperature, the alarm indicator light will light up and the buzzer will also sound.
4. Internal parameter adjustment: see attached page.
5. Lighting usage method: Turn on the lighting switch, and the lights inside the box will turn on.
VILow temperature biochemical incubatorPrecautions and Maintenance
During transportation, the incubator should not be inverted or placed flat at an angle greater than 45 degrees.
2. Do not frequently change the set value during use to avoid overloading caused by frequent compressor start-up, which may affect the service life of the equipment.
When there is no need for lighting inside the box, the lighting should be turned off to avoid affecting the upper layer temperature and prolong the service life of the lamp tube.
4. This machine is equipped with a set of fuses. If there is a malfunction during operation, please cut off the power first, check if the fuses are intact, and then check other parts.
To maintain the appearance of the equipment, do not wipe the surface with corrosive solution. The box can be wiped with a dry cloth or alcohol to keep the box clean.
When the equipment is not in use, the box should be kept dry and the power should be cut off.
To ensure uniform temperature inside the box, it is necessary to regularly check whether the axial flow fan inside the box is operating normally. During the experiment, items inside the box should not be placed too densely and should not block the fan outlet to facilitate airflow circulation inside the box.
8. If the equipment malfunctions, professional personnel should be hired for repair or the sales department of our factory should be contacted. Users are not allowed to dismantle or repair it arbitrarily.
Note: Special specifications can be customized. From the date of product sale, if there are any quality problems within one year, our factory is responsible for free maintenance and lifelong maintenance.
Product related keywords: Low temperature biochemical incubator