MOSFET, CMOS, IGBT semiconductor I-V, C-V characteristic curvesSemiconductor characteristic curve plotting instrument, suitable for MOSFETs CMOS,IGBT, Testing of current voltage (I-V) and capacitance voltage (C-V) characteristics of materials, processes, and semiconductor devices such as transistors and diodes.
Professional instrument equipment and testing solution supplier——Shanghai Jianrong Industrial Co., Ltd. JETYOO Industrial&Jianyou (Shanghai) Measuring Instrument Co., Ltd. JETYOO SYSTEMS, formerly a product technical support engineer at Agilent (now Germany KEYSIGHT)——Jian JETKEITHLEY, a loyal user engineer at Tektronix——RongyooCo founded in 2012, with the aim of breaking through the old and establishing the new! Fill the gap in the electronic measurement industry where agent distributors only specialize in business sales, lack expertise in pre-sales testing solutions, and lack expertise in after-sales training. Our technical sales engineers have a bachelor's degree or above and have over 10 years of work experience in the instrument industry, specializing in providing services to users in ChinaMOSFET, CMOS, IGBT semiconductor I-V, C-V characteristic curves, a company in the East China region of ShanghaiTechnology orientedA comprehensive service provider for instruments and equipment.
IWATSU Semiconductor Characteristic Curve Grapher CS-3100, CS-3200,CS-3300Series (compliant with UL specifications)
Very suitable for measuring the characteristics of different types of semiconductors (including IGBT, MOSFET, transistor, and diode)
Maximum peak voltage: 3000 V (high voltage mode, suitable for all models)
Maximum peak current: 1000 A (CS-3300 high current mode)
All models support leakage current (LEAKAGE) test mode (cursor resolution: 1 pA)
USB interface (for saving screen images and setting conditions)
LAN interface (remote control)
|
product name |
model |
notes |
host |
semiconductor curve tracer |
CS-3100 |
3000V/No High Current Mode - CS-301/CS-500 |
semiconductor curve tracer |
CS-3200 |
3000V/400A (high current mode) - CS-302/CS-500 |
|
semiconductor curve tracer |
CS-3300 |
3000V/1000A (high current mode) - CS-302/CS-500 |
|
Test Bench |
S-type test bench |
CS-301 |
CS-3100 standard configuration |
M-type test bench |
CS-302 |
CS-3200/CS-3300 standard configuration |
|
Test Adapter |
Test Adapter |
CS-500 |
The main control device comes with 1 test adapter |
TO type test adapter |
CS-501 |
Suitable for TO type packaging (3 pins) socket |
|
Alligator Clip |
Small crocodile clip (red) x 10 |
CS-001 |
M-type test bench options: CS-302 |
Small crocodile clip (black) x 10 |
CS-002 |
M-type test bench options: CS-302 |
|
Software Options |
Semiconductor parameter search |
CS-800 |
This software option needs to be installed in conjunction with the CS-3000 series |
Semiconductor parameter measurement |
CS-810 |
When CS-800 is installed in the main control device, this option can be used on a PC (optional). |
User friendly measurement screen
Example of V-I Characteristics of Graphic Configuration Screen Transistor (Tracking Mode)
Example of I-V Characteristics of Transistor Selection in Graphic Configuration (Trace Mode)
Vbe and Ic waveforms in high current pulse mode (wave mode)
Vbe and Ic waveforms in high current pulse mode (wave mode)
IWATSU Semiconductor Characteristic Curve Grapher CS-3100, CS-3200, CS-3300 Specification Parameters and Indicators
project |
CS-3100 |
CS-3200 |
CS-3300 |
||||||||||||||||||||
Collector power supply | |||||||||||||||||||||||
|
mode |
high voltage |
AC、 ± Full wave rectification, ± DC, ± LEAKAGE |
||||||||||||||||||||
large current |
- |
pulse |
|||||||||||||||||||||
|
The maximum peak power |
120 mW, 1.2 W, 12 W, 120 W, 390 W |
|||||||||||||||||||||
- |
High current mode (400 W, 4 kW) |
High current mode (400 W, 4 kW, 10 kW) |
|||||||||||||||||||||
|
High voltage mode |
|
|||||||||||||||||||||
|
Loop correction |
The stray capacitance between the collector pin of the test bench and the ground is compensated by hardware in high voltage mode, and digital compensation can also be provided. |
|||||||||||||||||||||
|
High current mode (pulse) |
- |
|
|
|||||||||||||||||||
|
Pulse width/measurement point |
- |
The pulse width can vary within the range of 50-400 μ s. |
||||||||||||||||||||
|
Upper limit of data points |
Each tracking can specify 20-1000 points. |
|||||||||||||||||||||
step generator | |||||||||||||||||||||||
|
current mode |
Amplitude range: 50 nA -200 mA, a total of 21 ranges, with steps of 1-2-5 |
|||||||||||||||||||||
|
Voltage Mode |
Amplitude range: 50 mV -2 V, a total of 6 ranges, with steps of 1-2-5 |
|||||||||||||||||||||
|
step rate |
Trapezoidal wave: 50 Hz or twice 60 Hz |
Trapezoidal wave: twice 50 Hz or 60 Hz (50 Hz or 60 Hz in AC mode) |
||||||||||||||||||||
|
Pulse stepping |
The pulse width can vary within the range of 50 μ s to 400 μ s (with a resolution of 10 μ s). |
|||||||||||||||||||||
|
Step number |
0-20 steps |
|||||||||||||||||||||
AUX output | |||||||||||||||||||||||
|
range |
Close- 40V -+40V, varying at a resolution of 100mV |
|||||||||||||||||||||
vertical axis | |||||||||||||||||||||||
|
Collector current |
range |
High voltage mode: 1 μ A/div -2 A/div, a total of 20 ranges, with steps of 1-2-5. |
||||||||||||||||||||
- |
High current mode: 100 mA/div -50 A/div, with a total of 9 ranges and steps of 1-2-5. |
High current mode: 100 mA/div -100 A/div, with a total of 10 ranges and steps of 1-2-5. |
|||||||||||||||||||||
accuracy |
2% reading+0.05 × VERT/div setting value or lower (the internal loop correction error below must be added to the formula on the left) |
||||||||||||||||||||||
|
Emitter current (leakage) |
range |
1 nA/div -2 mA/div, a total of 20 ranges, with steps of 1-2-5 |
||||||||||||||||||||
accuracy |
2% reading+0.05 × VERT/div set value+1 nA or lower |
||||||||||||||||||||||
horizontal axis | |||||||||||||||||||||||
|
Collector voltage |
range |
High voltage mode: 50 mV/div -500 V/div, a total of 13 ranges, with steps of 1-2-5 |
||||||||||||||||||||
- |
High current mode: 50 mV/div -5 V/div, a total of 7 ranges, with switching steps of 1-2-5 |
||||||||||||||||||||||
accuracy |
2% reading+0.05 x HORIZ/div set value or higher |
||||||||||||||||||||||
|
Base/emitter voltage |
range |
50 mV/div -5 V/div, a total of 7 ranges, with steps of 1-2-5 |
||||||||||||||||||||
accuracy |
2% reading+0.05 x HORIZ/div set value or higher |
||||||||||||||||||||||
other | |||||||||||||||||||||||
|
monitor |
8.4-inch color TFT LCD screen (SVGA 800 x 600 pixels) |
|||||||||||||||||||||
|
Data saving/reading |
Built in: Memory (setting: 256, REF waveform: 4) |
|||||||||||||||||||||
|
USB |
1 port (USB1.1) |
|||||||||||||||||||||
|
Remote control |
Remote control via LAN: 1 port (100BASE-TX) |
|||||||||||||||||||||
|
Power supply/power consumption |
Power input range: 100-240 V AC, |
|||||||||||||||||||||
|
accessory |
CS-301 (S-type test bench) |
CS-302 (M-type test bench) |
||||||||||||||||||||
mechanical part | |||||||||||||||||||||||
|
Size (mm) |
424 (length) x 555.2 (width) x 221 (H) (excluding external protrusions) |
424 (length) x 555.2 (width) x 354.5 (H) |
||||||||||||||||||||
|
weight |
About 30 kg (excluding optional accessories) |
Approximately 45 kg (excluding optional accessories) |
||||||||||||||||||||
|
environmental condition |
Working temperature: 0-+40 ° C |
CS-3100, CS-3200, CS-3300 functions
Observing I-V curves and application waveforms of voltage and current
Application of current and voltage pulses in high current mode
The pulse width of the applied current and voltage, as well as the rated measurement point, can be set between 50-400 μ s (CS-3200 and CS-3300).
Example of Measurement of MOSFET "Current" and "Voltage" Characteristics
You can choose 'SWEEP TYPE' as the scanning category
The 'Scan Categories' include' Down ',' Up ', and' Custom '(all modes).
If the "custom" mode is specified, the range between specified values can be scanned.
CS-800 semiconductor parameter search (optional)
The software options of the main control device support voltage and current limiting functions, as well as automatic Vth measurement function.
Limit SWEEP
If voltage and current limits are specified before the 'scan' operation, the operation will stop at the next measurement point after exceeding the limits.
Vth and hFE settings
Vth and hFE can be automatically measured.
Example of Vth automatic measurement.
Remote Tools
If USB storage is not allowed due to security reasons, screenshots, CSV format measurement results, and other data can be directly transferred to a personal computer through a local LAN.
Free remote operation software is provided. But when using this software, you must install the NI VISA library (which requires a fee).
CS-810 Semiconductor Parameter Measurement (Optional)
This is a computer application used to connect a main control device equipped with CS-800 to a personal computer via a local area network (optional). This application can automatically measure and determine the accuracy of data based on the measurement conditions specified by the personal computer.
Introduction to CS-3100, CS-3200, CS-3300 Panels
1 Display screen
The 8.4-inch bright screen can display detailed waveform information. Using a large-sized screen, menus and parameters can be displayed without affecting the waveform grid.
2 Connectivity
The CS-3000 series is equipped with a USB port on the front panel for easy report generation. Press the Copy button to save the screenshot to a USB device.
3. Read the display screen
The display screen uses different colors to represent different functions, and the operation settings are clear at a glance.
4 Circuit breakers
High voltage (all models) and high current (CS-3200/3300) circuit breakers are provided on the front panel.
5 Menu Operations
Use the function knobs and function keys to operate the menu.
6 Copy button
7 Configuration button
Used to display connection and signal application status.
8-Step Generator
This dedicated knob can be used to set the step and offset.
9 View/Pulse (VIEW/PULSE) button
Used to switch between Trace and WAVE views.
In the waveform view, the time axis waveforms of applied voltage and current are masked and displayed, which cannot be observed by conventional curve trackers.
10 Vertical and Horizontal Knobs
These specialized knobs are installed in places that are easy to operate.
Variable 11 knob
Used to regulate the output voltage of the collector power supply.
The durable knob is suitable for frequent use.
CS-3100, CS-3200, CS-3300 optional accessories
Standard accessory
Standard attachments for CS-3100
CS-301
CS-301 S-type test bench CS-500
When installing CS-501 on the CS-500 test adapter
Standard attachments for CS-3200 and CS-3300
CS-302
CS-302 M-type test bench CS-500
When removing the wiring panel from the CS-500 test adapter
pencil
pencil
CS-500 Test Adapter
The CS-500 adapter comes with the product. Use this adapter to connect the prepared fixture to the test bench connector.
option
CS-501 TO type test adapter
This socket is suitable for TO type packaging (3 pins) and supports pin distances of 1.52-4.57 mm. CS-501
CS-001 (red x10), CS-002 (black x10)
Small spring clip
These small spring clips can be installed on the wiring harness that comes with the CS-302 test bench. CS-001、CS-002
Power characteristic curve plotting instrument CS-10000 series (CS-10800/CS-10400) (BTO)
It is an ideal choice for measuring the characteristics of power devices
High voltage mode
Output voltage: 500 V -10 kV (DC only)
Output current: Zui High 500 mA
Output pulse width: 700 μ s-4500 μ s (with a step size of 1 μ s)
High current mode
Output voltage: 0 V - 50 V
Output current: Zui supports up to 8000 A.
Output pulse width: 700 μ s (fixed)
Power characteristic curve graphing instrument
10 kV characteristic curve plotting instrument (BTO)
It is an ideal choice for measuring the withstand voltage characteristics of high-voltage diode thyristors
Output section
Voltage waveform: Half wave rectified waveform of commercial power supply
Maximum voltage: 10 kV (peak, no load)
Zui high current: 100 mA (peak)
Display Section
Voltage axis sensitivity: 50 - 1000 V/div
5 ranges, with steps of 1-2-5
Current axis sensitivity: 0.1 - 10 mA/div
5 ranges, with steps of 1-2-5