The MTS Criterion 60 series system performs high-precision and reliable tensile and compression tests on high-strength specimens of different shapes and sizes. These high-strength test systems use reliable MTS servo controlled hydraulic actuation systems and high-speed, digital closed-loop controllers to achieve force control, displacement control, or strain control tests from 300kN to 1000kN. The C60 series system currently has a complete set of high-strength 6-column load frame configurations, which are supported by a compact and ergonomic integrated operating platform. The easy-to-use TestWork software, a rich and constantly increasing library of test method standards, and various attachments enable this system to be widely used in the entire range of high-strength metals and building materials
include:
Metal sheets, metal plates, metal rods, fasteners, metal wires and cables, chains, pipes and tubular materials, structural steel bars, welded parts, castings, forgings, structural components, rock and concrete pavement fasteners (non-metallic), wires and cables (non-metallic), reinforcement materials (non-metallic)
Main characteristics
1: High stiffness 6-pillar load frame configuration
2: Reliable MTS servo controlled hydraulic actuation system
3: High resolution, digital closed-loop controller
4: Convenient experimental setup and handheld device
5: Multi functional and easy-to-use TestWork software, equipped with a rich and constantly increasing library of test method standards (ASTM, ISO, DIN, EN, BS, etc.)
6: Complete set of alternative fixtures, accessories, environmental systems, and extensometers
7: Compact and ergonomic integrated operating platform
8: Standard dual test space to reduce setup time
9: Upper space stretching
10: Lower space compression
11: Stepless loading
12: Quick return hydraulic valve to improve work efficiency
13: Beam displacement limit protection, force overload protection, overheating protection, voltage overload protection, etc
14: Optional independent safety cover that complies with EU standards
15: Fully compliant with "Mechanical Equipment 2006/42/EC", "Low Voltage 2006/95/EC", "EMC Directive 2004/108/EC" and GOST-R
16: Durable and long-lasting test space protection
17: Easy to maintain
Technical parameters:
Specification and model | C64.305 | |
Rated load | kN | 300 |
lbf | 67500 | |
Column configuration | Number of columns | 6 |
Experimental space | Single/Double | double |
Actuator (piston) stroke | mm | 150 |
in | 5.91 | |
Actuator (piston) speed | Mm/min | 0.5 - 1800.0004-7.09 |
In/min | ||
Beam speed | mm/min | 220 |
in/min | 8.66 | |
Column spacing (width of test space) | mm | 40015.75 |
in | ||
Large compression space | ||
Standard length | mm | 54021.26 |
in | ||
Extended length | mm | 93536.81 |
in | ||
Large stretching space | ||
Standard length | mm | 52520.67 |
in | ||
Extended length | mm | 90035.43 |
in | ||
Diameter of circular specimen | mm | 6-32 |
in | 0.24-1.26 | |
Thickness of flat specimen | mm | February 25th |
in | 0.07-0.98 | |
Pressure plate | mm | 150 x 150 (square) |
in | 5.91 x 5.91 (square) | |
Frame height | ||
Standard length | mm | 2074 |
in | 82 | |
Extended length | mm | 247097.24 |
in | ||
Frame width | mm | 870 |
in | 34. 25 | |
Depth of Framework | mm | 725 |
in | 28.54 | |
Frame weight | ||
Standard length | kg | 1950 |
Lb | 4300 | |
Extended length | kg | 20034416 |
Lb |
Calibration standards | ISO 7500 Grade 0.5 or ASTM E4 | ISO 7500 Level 1 | |
Measurement range* | 1% -100% rated load | 0.5% to 1% rated load | |
Displacement resolution | 0.2μm | ||
(0.00000787in) | |||
Displacement accuracy | +/-1% of the displayed value | ||
Strain accuracy | ASTM E83 or ISO 8513 | ||
safeguard | Force overload protection, travel limit, oil pressure overload protection, overheating protection, voltage overload protection, and others | ||
Force overload protection | 10% | ||
Data collection frequency | 1000Hz | ||
Control loop frequency | 1000Hz | ||
Environmental requirements | |||
Working temperature range | 5 to 40 ℃ | ||
41 to 104 ° F | |||
Working humidity | 5-85% non condensing | ||
Storage temperature range | -18 to 49 ℃ | ||
0 to 120 ° F | |||
High storage humidity | 90% non condensing | ||
High altitude | 2000 meters | ||
Integrated Operating Platform (IOP) power requirements | 400V 50Hz/480V 60Hz V AC | ||
(3 phases) | |||
IOP size | mm | 1040 x 720 x 1900 | |
in | 38.58 x 28.35 x 74.8 | ||
IOP weight | kg | 400 | |
Lb | 881.85 |