project name |
HDI |
|
control mode |
SPWM |
|
Input power supply |
380VPower Supply:330~440V;220VPower Supply:170~240 |
|
Five digit digital display And status indicator lights |
Display frequency, current, speed, voltage, counter, temperature, forward and reverse status, faults, etc. |
|
Communication Control |
RS-485 |
|
operate temperature |
-10~40℃ |
|
humidity |
0~95%Relative humidity (non condensing) |
|
vibrate |
0.5Gbelow |
|
frequency control |
range |
0.10~400.00Hz |
accuracy |
Digital:0.01%(-10~40℃); Simulated:0.1%(25±10℃) |
|
Set resolution |
Digital:0.01Hz; Analog: Maximum operating frequency1‰ |
|
output resolution |
0.01Hz |
|
Keyboard setting method |
You can directly use ←∧∨setting |
|
Simulation setting method |
External voltage0-5V,0-10V,4—20mA,0—20mA. |
|
Other functions |
The lower limit of frequency, starting frequency, stopping frequency, and three jumping frequencies can be set separately |
|
general control |
Acceleration and deceleration control |
4Segment acceleration and deceleration time(0.1-6500Choose freely in seconds |
V/Fcurve |
Can be set arbitrarilyV/Fcurve |
|
Torque control |
Can set torque boost, maximum10%The starting torque is1.0HzTime reachable150% |
|
Multi functional input terminal |
6Multiple multifunctional input terminals, realizing8Segment speed control, program execution,4Switching between acceleration and deceleration,UP、DOWNFunctions such as functionality, counter, external emergency stop, etc |
|
Multi functional output terminal |
have5Multiple multifunctional output terminals, realizing indication and alarm of running, zero speed, counter, external abnormalities, program operation, etc |
|
Other functions |
Automatic voltage stabilization(AVR)Deceleration stop or free stop, DC brake, automatic reset and restart, frequency tracking,PLCProgram control, lateral control, adjustable carrier, up to20KHzclass |
|
Protection function |
overload protection |
Electronic relay protection motor Driver (constant torque)150%/1Minutes, fan class120%/1Minutes) |
FUSEfuse protection |
FUSECircuit breaker, motor stops |
|
Overvoltage |
220VLine: DC voltage>400V;380VLine: DC voltage>800V |
|
Insufficient voltage |
220VLine: DC voltage<200V;380VLine: DC voltage<400V |
|
Instant power outage and restart |
After a sudden stop, it can be restarted in frequency tracking mode |
|
Stall Prevention |
add/Preventing stall during deceleration operation |
|
Short circuit at output end |
Electronic circuit protection |
|
Other functions |
Overheating protection for heat sinks, reverse restriction, direct start-up and fault recovery after startup, parameter locking, etc. |