The input of the frequency converter is three-phase380V 50HZ The output is three-phase0-380V 0-400HZ.
Inverter input terminal connectionR S T, output endU V
WConnect the electric motor. Actual size:
220*150*175 |
MMLWH |
|
project name |
HDI |
|
series |
control modeSPWMInput power supply380VPower Supply:330~440V; |
|
220V Power Supply: |
170~240 |
|
Five digit digital display |
And status indicator lights |
|
Display frequency, current, speed, voltage, counter, temperature, forward and reverse status, faults, etc. |
Communication ControlRS-485 |
|
operate temperature |
-10~40℃ |
|
humidity |
0~95%Relative humidity (non condensing) |
|
vibrate |
0.5G |
below |
frequency control |
range0.10~400.00HzaccuracyDigital:0.01%(-10~4025℃); Simulated:100.1% |
|
( |
±℃)Set resolution1Digital: |
|
0.01Hz |
; Analog: Maximum operating frequency |
|
‰ |
output resolution0.01HzKeyboard setting method |
|
You can directly use ← |
∧∨settingSimulation setting methodExternal voltage0-5V4,0-10V,0—20mA, |
|
— |
20mA |
|
. |
Other functions |
4The lower limit of frequency, starting frequency, stopping frequency, and three jumping frequencies can be set separatelygeneral controlAcceleration and deceleration control |
Segment acceleration and deceleration time(0.1-6500 |
Choose freely in secondsV/Fcurve |
|
Can be set arbitrarily |
V/FcurveTorque controlCan set torque boost, maximum10%The starting torque is |
|
1.0Hz |
6Time reachable8150%4Multi functional input terminalMultiple multifunctional input terminals, realizingSegment speed control, program execution,Switching between acceleration and deceleration,UP |
|
、 |
DOWN5Functions such as functionality, counter, external emergency stop, etc |
|
Multi functional output terminal |
haveMultiple multifunctional output terminals, realizing indication and alarm of running, zero speed, counter, external abnormalities, program operation, etcOther functionsAutomatic voltage stabilization(AVR)Deceleration stop or free stop, DC brake, automatic reset and restart, frequency tracking,PLC |
|
Program control, lateral control, adjustable carrier, up to |
20KHz |
class Protection functionoverload protectionElectronic relay protection motorDriver (constant torque)150%/1 |
Minutes, fan class120%/1 |
Minutes)FUSE |
|
fuse protection |
FUSECircuit breaker, motor stopsOvervoltage220VLine: DC voltage>400V; |
|
380V |
Line: DC voltage>800VInsufficient voltage220VLine: DC voltage<200V; |
|
380V |
Line: DC voltage< |
|
400V |
Instant power outage and restartAfter a sudden stop, it can be restarted in frequency tracking modeStall Prevention |
|
add |
/ |
|
Preventing stall during deceleration operation |
Short circuit at output end |