YXCWidely used in industrial sectors such as petroleum, chemical, metallurgical, and power stations, or in the measurement of pressure of various fluid media without explosion hazards in mechanical and electrical equipment. Usually, instruments can be used in conjunction with corresponding electrical components (such as relays and contactors) to achieve automatic, control, and alarm functions for the measured (controlled) pressure system. In order to adapt to the different needs and requirements of the tested objects, this system instrument has developed more than 10 types of products, including anti vibration, corrosion-resistant, corrosion-resistant and seismic resistant, as well as isolation devices, on the basis of the original ordinary and professional types.
This series of instruments not only has the characteristics of novel design, reliable structure, complete variety, stable operation, and strong adaptability, but also has the advantages of combined measurement and control, simple installation, and low maintenance. Therefore, it is an unparalleled pressure measurement and control instrument compared to general pressure controllers without indication, switching difference adjustment, and external setting devices.
Model designation
□
|
Other functions; F - Corrosion resistance; Z-seismic resistance; FZ - Corrosion resistant, seismic resistant and pressure guiding system and shell materials; stainless steel
|
B-
|
Instrument nominal diameter and form;
|
□
|
100 and 150 respectively represent directional shapes with diameters of 100 and 150MM
102 represents a radial posterior equation with a diameter of 100MM
103 and 153 respectively represent axial embedded types with diameters of 100 and 150MM
|
□-
|
A - Suitable for ammonia and its mixtures
G-with isolation device
|
C
|
Contact device form: magnetic assisted action type
|
X
|
Control mode; Slow moving contact position form
|
Y
|
Instrument category: pressure instrument
|
Main technical indicators and functions
Scale range, accuracy level, and joint thread size
type
|
model
|
name
(including full name or abbreviation)
|
Scale range MPA
|
Accuracy class
|
Joint thread
(Size)
|
indicate
|
set value
|
put through
|
break
|
M20×1.5
(*G3/8")
(*G1/2")
|
Common
|
YXC-100
*YXC-102
YXC-103
|
YXC
|
-0-0.16 to 60 and
-0.1-0.06 to 2.4 series
0-0.1 to 60 and
-0.1 to 2.4 series
|
1.6
|
1.5
|
4
|
YXC-150
*YXC-153
|
specialized
|
YXC-150
|
Magnetic assisted electric contact ammonia pressure gauge
|
0-0.16 to 60 and
-0.1-0.06 to 2.4 series
|
2.5
|
2.5
|
4
|
Seismic type
|
YXC-100-Z
*YXC-102-Z
YXC-103-Z
|
YXC
|
0-0.6 to 60 and
-0.1-0.5 to 2.4 series
|
1.6
|
1.5
|
5
|
Corrosion resistant type
|
*YXC-100-F
*YXC-102-F
*YXC-150B-F
*YXC-152B-F
*YXC-153B-F
|
0-0.16 to 60 and
-0.1-0.06 to 2.4 series
|
1.6
|
1.5
|
4
|
Corrosion resistant and seismic resistant type
|
*YXC-100-FZ
*YXC-102-FZ
*YXC-150B-FZ
*YXC-153-FZ
|
|
0-0.6 to 60 and
-0.1-0.06 to 2.4 series
|
1.6
|
1.5
|
5
|
|
Isolation ordinary
Isolated corrosion-resistant type
|
YXCG-103
*YXCG-103-F
|
Isolated magnetic assisted contact pressure gauge
|
0-0.16 to 60 and
-0.1-0.06 to 2.4 series
|
1.6
|
1.5
|
4
|
M24×2
1
(*G1/4")
|
Isolation seismic type
|
YXCGG-103-Z
|
0-0.6 to 60 and
|
1.6
|
1.5
|
5
|
Isolation type, corrosion-resistant and seismic resistant
|
*YXC-103-FZ
|
-0.1-0.5 to 2.4 series
|
|
|
|
Note 1: Models marked with "*" are temporarily limited to special orders
Note 2: The isolated soft tail length is 1, 2, 3, and 4M (with 2M being the preferred length)
Electrical parameters and control forms of contact devices
Contact power
|
maximum working voltage
|
maximum operating current
|
control form
|
30VA (resistive load)
|
220VD. C or 380A C
|
1A
|
Upper and lower limits, dual upper limits, dual lower limits
|
Note:; When the current is 1A; The working voltage should be below 40V.
Environmental conditions for use
type
|
Working temperature range
Medium; surrounding environment
|
relative humidity
|
Anti working vibration performance
|
Commonality and specificity
|
-40~70℃
|
Not exceeding 85%
|
V. Level H.3
|
Corrosion Resistance
|
-25~55℃
|
Not exceeding 90%
|
V. Level H.3
|
Anti vibration type, corrosion and vibration resistance
|
V. H.4 level
|
Isolation type ordinary type
|
Below 150 ℃
|
-40~70℃
|
V. Level H.3
|
Isolated corrosion-resistant type
|
-40~70℃
|
Isolation type other types
|
Below 150 ℃
|
-25~55℃
|
V. H.4 level
|
Temperature influence; The displayed value shall not exceed 0.4%/10 ℃ (with a temperature deviation of 20 ± 5 ℃)
Structural principle
The instrument consists of a measurement system, an indication system, a magnetic assisted electrical contact device, a housing, an adjustment device, and a junction box (plug socket).
The working principle of the instrument is based on the spring tube in the measurement system, which, under the pressure of the measured medium, causes the end of the spring tube to produce corresponding elastic deformation and displacement. With the help of a pull rod transmitted through a gear transmission mechanism and amplified, it is indicated by the fixed gear
(Along with the contacts) indicate the measured values on the dial one by one. At the same time, when it comes into contact with the contact point (upper or lower limit) on the set pointer (dynamic breaking or dynamic closing), it causes the circuit in the control system to be disconnected or connected, in order to achieve automatic control and send alarm signals.
|