1Equipment principle and composition:
The AUK-CIO medical electrolytic salt method hypochlorous acid generator is a device that uses a double diaphragm method to electrolyze and dilute sodium chloride (NaCl) solution to produce hypochlorous acid solution.
The electrolytic power supply adopts a DC power supply with a voltage not exceeding 24V or 36V. In an electrolytic cell with special electrode plates (titanium based coated rare metal oxides of ruthenium, rhodium, iridium, and platinum), dilute saltwater with a predetermined concentration is electrolyzed to produce hypochlorous acid solution. All units of the system are centrally controlled by PLC and equipped with LCD touch screens. Users can understand the current operating status of the system and control various functions through touch operations. The system has automatic detection and protection functions, and can operate fully automatically. It is stable, reliable, easy to operate, and safe.
The hypochlorous acid generator includes electrolysis host, intelligent control system, saltwater tank, storage tank and other units, which can conveniently and safely produce high-quality, pure, efficient, broad-spectrum, safe and non-toxic hypochlorous acid disinfectant solution.
The total electrochemical reaction of the electrode is expressed as follows:
2NaCl + 2H2O = 2NaOH + H2 + Cl2
Cl2+H2O = HCl+HClO
Product schematic diagram
Composition structure diagram
2、 Scope of Equipment Application
Hypochlorous acid is currently recognized as an oxidant with the strongest bactericidal ability. Its bactericidal ability is 80-100 times that of sodium hypochlorite disinfectant, and it has the characteristics of high efficiency, broad-spectrum, biodegradability, no residue, and green safety. Can kill intestinal pathogenic bacteria and pyogenic cocci, and can also inactivate viruses. Therefore, it can meet the disinfection requirements in various aspects of daily hospital work, and will not cause corrosion to equipment, making it safe and efficient.
Medical device disinfection, daily hygiene disinfection
hospitalsewagedisinfect Air disinfection
Ward disinfection Disinfection of medical staff
Hospital wastewater contains a large amount of pathogenic bacteria and residual drugs. This type of wastewater not only contains a large amount of antibiotics, but also poses a threat to the health of surrounding organisms. Therefore, China requires medical wastewater to be treated before discharge. Among all the current water disinfection processes, we highly recommend hospital owners to use hypochlorous acid generators to disinfect wastewater. The main reason is that this group of users face difficulties in purchasing chemical raw materials, and there are safety hazards associated with chemicals. Hospitals are also densely populated areas. The raw material used in the hypochlorous acid generator is table salt, which can be found everywhere and is very safe, so users can use it freely without worrying about safety issues.
IIIPrecautions for safe use
1. Water God: Hypochloric acid water must not contain any additives or other substances (strictly prohibited from being mixed with other chemical agents);
2. Hypochloric acid water is mainly used for disinfection and sterilization, and is not recommended for consumption. If you feel unwell after accidentally drinking it, it is recommended to seek medical examination;
3.The power cord must be plugged into a standard three hole AC socket that is effectively grounded with a standard wire,Otherwise, it may cause fire or electric shock;
4. Do not operate this machine or plug or unplug power sockets with wet hands, as there is a risk of electric shock;
5. Hypochloric acid water is a chlorine containing disinfectant. If allergic to chlorine gas, use with caution;
6. When using the hypochlorous acid water disinfectant generated by this equipment for disinfection treatment, it should be prepared and used immediately;
When the effective chlorine concentration of hypochlorous acid disinfectant is below 10% of the standard, it is recommended to stop using it and notify the after-sales service unit for handling;
When the pH value of hypochlorous acid disinfectant is below 3.5, it is recommended to stop using it and notify the after-sales service unit for handling.
4characteristic
1. The raw materials are simple and safe, easy to store, transport, and manage;
2. Thoroughly remove biofilms from the hospital's water supply system to ensure the safety of hospital water usage;
3. Fast, efficient and broad-spectrum sterilization, meeting the hospital's requirements for sterilization;
4. The solution is non-toxic and non corrosive, and there is no risk of equipment being corroded or potential harm to personnel;
5. Used in different stages, the concentration is automatically diluted without increasing labor intensity, and the concentration is stable;
6. Low cost, the production cost of 1000 milliliters of 500ppm disinfectant solution is only 0.02 yuan;
7. Automated system operation, on-demand production, reducing management costs such as purchasing, transporting, and storing disinfectants;
8. The solution is biodegradable without residue and does not increase the cost of subsequent wastewater treatment.
Main technical parameters and indicators:
Input voltage: 220VAC/50Hz (with grounding);
Rated power: 200W~1000W;
Working voltage: DC12V;
Liquid concentration: 100-1000ppm (customizable);
Salt water concentration: 0.1%;
Sodium removal rate: 99.9%;
Working mode: fully automatic operation;
Chlorine production: 10-1000 grams per hour (customizable);
Salt water tank: food grade PE tank;
Hypochloric acid tank: food grade PE tank;
Whole machine support: The aluminum profile frame serves as the base and adopts an integrated installation method.