Meixi (China) UV-1300PC UV Visible spectrophotometerTechnical indicators and basic parameters:
*Wavelength range: 190~1100nm
*Spectral bandwidth: 4nm
*Wavelength accuracy: ±0.5nm
*Wavelength reproducibility: ≤ 0.2nm
*Transmittance accuracy: ±0.5% τ
*Transmission density repeatability: 0.2% τ
*Wavelength adjustment: automatic adjustment
*Luminous range:- 0.3~3A
*Display mode: 128 * 64 LCD
*Stray light: ≤ 0.05% τ (220nm NaI,340nm NaNO2)
*Stability: 0.001A/h (after preheating at 500nm)
*Measurement methods: transmittance, absorbance, concentration, energy
*Detector: Imported silicon photodiode
*Light source: imported deuterium lamp, imported tungsten lamp
*Power supply: AC 220V/50Hz 110V/60Hz
*Power: 120W
*Instrument size: 480 × 350 × 220mm
*Net weight of the host: 15Kg
Meixi (China) UV-1300PC UV Visible spectrophotometerInstrument features
*Adopting single-chip microcomputer control, 128 * 64 bit LCD display
*The spacious LCD display can display multiple sets of data
*Huge memory space, capable of storing multiple sets of data and curves
*Automatic 0 and 100% adjustment function
*Automatic wavelength adjustment
*Automatic lamp change, automatic color filter change, wide sample cell (0.5mm~100mm)
*Capable of measuring the standard curve of the top ten standard samples
*Quantitative measurement can be achieved by directly inputting K and B factors to establish a standard curve
*Can directly input standard samples and corresponding concentration values to establish a standard curve for quantitative measurement
*Adjustable electrical storage of standard curve parameters for measurement settings, capable of saving multiple standard curves
*Standard curves can be edited at any time, making it convenient for users to use
*Equipped with a universal parallel printing interface or micro printing interface, it can print title blocks, measurement data, curve parameters, curve standard sample points, and curves
*Equipped with USB interface
*More precise and flexible measurement requirements can be achieved through PC control (standard)
software function
Wavelength scanning: Full band spectrum scanning from 190nm to 1100nm can be performed on the tested substance, or segmented scanning can be performed
Dynamics testing: Time scanning of the tested substance to timely detect changes in absorbance caused by changes in concentration
Quantitative measurement: By establishing a standard curve, concentration analysis of the measured substance can be performed
Multi wavelength testing: Multiple wavelengths can be set simultaneously to test the absorbance of the tested substance at multiple wavelengths
DNA/protein testing: purity and concentration analysis of DNA/protein using nucleic acid protein testing formula