purpose
|
|
ZY-3051DR type micro differential pressureTransmitterIt can convert small differential pressure into 4-20mA DC signal, which adopts specially designed amplification circuit board and special temperature compensation process, has stable and reliable performance. It is an ideal product for detecting micro pressure, primary and secondary air flow, and airflow loss in furnace combustion chambers.
|
General technical performance and parameters
|
Output signal: 4-20mA DC two-wire system (analog) The two-wire 4-20mA DC signal is overlaid with a digital signal, and the user selects linear or square root output. (Intelligent) Power supply: 12-45V DC (see load characteristic diagram for details) Load characteristics:
|
|
Range ratio: 10:1 or 100:1 Power supply impact:<0.005% output range/V Load impact: When the power supply is stable, there is no load impact. Measurement accuracy: ± 0.1%, ± 0.2% of the calibration range (standard accuracy is ± 0.2%, if other accuracies are selected, please indicate them when ordering and selecting.) Damping: usually adjustable between 0.1 and 16 seconds. Start time:<2 seconds, no preheating required Working environment: ambient temperature -29~93 ℃ (analog amplifier) -29~75 ℃ (digital/smart amplifier) -29-65 ℃ (with display header) Environmental humidity: 0-95% Protection feature: IP65 protection capability Explosion proof type: Explosion proof Exd II BT4-6 Intrinsically safe Exia II CT5 Static pressure influence: Zero position error: ± 0.5% maximum range limit, calibrated by zeroing for 4MPa under pipeline pressure. Electromagnetic radiation impact: 0.05% maximum range value, accepted radiation frequency of 27-500MHz, test field strength of 3V/m. Indicator (%): LCD digital display accuracy ± 0.2% Vibration effect: ± 0.05%/g when vibrating at 200Hz in any direction. Installation position: The diaphragm is not installed vertically, which may result in a zero point error of less than 0.24KPa, but it can be corrected by adjusting the zero point. Weight: 3.9Kg (excluding accessories)
|
XY-3051DR type micro differential pressure transmitter
|
code
|
Measurement range (KPa)
|
2
|
0 - 0.125 ~ 1.5
|
|
code
|
output form
|
SF S
|
4~20mA. DC dedicated digital amplifier, linear output, 4-digit LCD digital display 4~20MA. DC dedicated intelligent amplifier, using HART protocol communication
|
|
code
|
Container and connector materials
|
Material of exhaust/drain valve
|
Isolation membrane material
|
12
22
|
carbon steel 316 steel
|
316 steel 316 steel
|
316L steel 316L steel
|
|
code
|
Fill liquid
|
not have
|
silicone oil
|
|
code
|
Allowable static pressure value (MPa)
|
A B
|
2
5
|
|
code
|
Optional parts
|
M3 B1 B2 B3 D1 D2 No note C1 C2 C3 d I
|
Digital display indicator with 4-digit LCD digital display Pipe installation bending bracket (installing pipe diameter 60) Board mounted bending bracket Pipe installation flat bracket (installation pipe diameter 60) The exhaust/drain valve is installed on the upper part of the side of the chamber The exhaust/drain valve is installed at the lower part of the side of the chamber Elliptical connector with internal thread NPT NPT external thread joint M20 × 1.5 T-shaped connector NPT external thread joint Explosion proof type, explosion-proof mark Exd Ⅱ BT4-6 Intrinsic safety type, explosion-proof mark Exia Ⅱ CT5
|
|
|
ZY-3051DR 2 F 12 A M1 B2 0-0.4KPa Selection Example
|
|
pourRefer to ZY-3051DP differential pressure for external dimensions, installation method, and pressure connection methodTransmitterThe method of pressure connection.
|