MilliQ IntegralLaboratory Pure Water Ultra Pure Water System Description:
abreast of the timesMilliporeMiliboMilliQ IntegralThe laboratory pure water system can directly produce pure water and ultrapure water from tap water, meeting the water needs of all laboratories. In addition,ElixTechnology and ion exchange resins continuously regenerated through weak current can greatly reduce your costs. MilliQ IntegralMain features of laboratory pure water and ultra pure water system: 1Stable and efficient preparation of pure water and ultrapure water Can produce every day70-360LPure or ultrapure water can fully meet the water needs of the laboratory. 2Comfortable and flexible water intake method Split typePOD(Water dispenser) makes it convenient and easy for you to fetch water PODThe water intake device has a small footprint and can even be installed on the wall POD(Water dispenser) can360Rotating degrees and adjusting heights to meet the water intake requirements of all laboratory vessels PODThe color display screen of the water dispenser can reflect all key water quality data, allowing you to know the operating status without looking at the host POD(Water dispenser) can support quantitative water intake 3Dual water quality monitoring Patent OnlineTOCThe monitor allows you to know the total organic content in water at any time High precision ion detector with low electrode constant design, compliant withASTMUnder the standardD1125-95(1999)Requirement, with temperature compensation function, and accurate to0.1℃. 4Intelligent system management Built in intelligent system, which can bring convenient and fast use. It can bring automatic system maintenance and exempt you from maintenance work. It can bring efficient system management, and the administrator and user settings ensure the stability of parameters. MilliQ IntegralApplication scope of laboratory pure water and ultra pure water system:
1.Select0.2umWhen using terminal filters, the produced water is suitable forHPLC,LC-MS,MALDI-TOF-MS,IC,ICP,AAWaiting for most analytical applications.
2.When selecting ultrafiltration columns, the produced water can be used for molecular biology applications (equivalent)DEPCProcessed pure water and cell culture.
3.SelectEDSWhen using columns, the produced water can be used for environmental analysisEDS(Endocrine interferon) research experiment.
4.The produced grade water is suitable for most basic laboratory applications, such as buffer and reagent preparation, microbial culture medium preparation, histology, dissolution experiments, and rinsing of glassware.
MilliQ IntegralTechnical indicators for water production of laboratory pure water and ultrapure water system
Milli-Q IntegralwithUS-EPA、EPandWHOThe standard tap water refers to incoming water.
Elixwater
|
|
resistivity
|
>5MΩ.cm @25 °C
|
TOC
|
<30ppb (μg/l)
|
Note: If fromE-PODUsing pure water can achieve the following water quality indicators:
parameter
|
numerical value
|
Company
|
Bacteria
|
<1(*)
|
cfu/ml
|
grain
|
>0.2 μm < 1 (*)
|
Particulates /ml
|
pyrogen(endotoxin)
|
<0.001(**)
|
EU/ml
|
RNases
|
<0.01(**)
|
ng/ml
|
DNases
|
<4(**)
|
pg/μl
|
(*)During installationMillipak Express 40Filter orBiopakWhen using ultrafiltration columns as terminal refiners (**)During installationBiopakWhen using ultrafiltration columns as terminal refiners The electrical resistivity of pure waterTOCConsistent with bacterial levelsISO3696、ASTMD1193 (IIGrade resistivityTOC、HBCsurfaceIindex)inIIGrade water andUSP ®、EPRequirements for pure water. Ultra pure water(IGrade water)Water Quality (*)During installationMillipak Express 40Filter orBiopakWhen using ultrafiltration columns as terminal refiners (**)During installationBiopakWhen using ultrafiltration columns as terminal refiners Ultra pure water meets the requirementsISO3696、ASTMD1193、USP ®、EPas well asCLSI ®- CLRWinIRequirements for grade water. Milli-Qwater(fromQ-PODAccess)
parameter
|
numerical value
|
Company
|
resistivity
|
18.2
|
MΩ.cm @25°C
|
TOC
|
<5
|
ppb (μg/l)
|
Bacteria
|
<1 (*)
|
cfu/ml
|
grain
|
>0.2 μm < 1 (*)
|
Particulates/ml
|
pyrogen(endotoxin
|
<0.001(**)
|
EU/ml
|
RNases
|
<0.01 (**)
|
ng/ml
|
DNases
|
<4(**)
|
pg/ μl
|
Parameters of water production system system>/pure water/Ultra pure water production(Max L/d)/E-PODPure water production(L/min)/Q-PODUltra pure aquatic water(L/min) Milli-Q Integral 3 70the height is2.0 0.05-2.0 Milli-Q Integral 5 120the height is2.0 0.05-2.0 Milli-Q Integral 10 240the height is2.0 0.05-2.0 Milli-Q Integral 15 360the height is2.0 0.05-2.0 quality assurance Product Qualification Certificate—Product according toMilliporestrictQAProgram installation and testing Verification certificate—Including the built-in resistivity meter andTOCDetector quality certification—Including all system consumables POD Pakverification—POD PakValidation of the effectiveness of removing specific target pollutants ISO 9001v. 2000andISO 14001Registered place of origin—If necessary, certificates can be provided CE、cUL、FC—To ensure the effectiveness and safety of the operation,Milli-Q IntegralThe system has been certified by safety and electromagnetic compatibility instructions.
|