Millipore MilliQ Integral Laboratory Pure Water Ultra Pure Water System
Millipore MilliQ Integral Laboratory Pure Water Ultra Pure Water System
Product details
Product Code:
11121927216
Product Name:
Millipore MilliQ Integral Laboratory Pure Water Ultra Pure Water System
Specifications:
MilliQ Integral
Product Remarks:
Product Category:
Ultrapure Water Polishing System
Product Description
MilliQ IntegralLaboratory Pure Water Ultra Pure Water System Description:

abreast of the timesMilliporeMiliboMilliQ IntegralThe laboratory pure water system can directly produce pure water and ultrapure water from tap water, meeting the water needs of all laboratories. In addition,ElixTechnology and ion exchange resins continuously regenerated through weak current can greatly reduce your costs.
MilliQ IntegralMain features of laboratory pure water and ultra pure water system:
1Stable and efficient preparation of pure water and ultrapure water
Can produce every day70-360LPure or ultrapure water can fully meet the water needs of the laboratory.
2
Comfortable and flexible water intake method
Split typePOD(Water dispenser) makes it convenient and easy for you to fetch water
POD
The water intake device has a small footprint and can even be installed on the wall
POD
(Water dispenser) can360Rotating degrees and adjusting heights to meet the water intake requirements of all laboratory vessels
POD
The color display screen of the water dispenser can reflect all key water quality data, allowing you to know the operating status without looking at the host
POD
(Water dispenser) can support quantitative water intake
3
Dual water quality monitoring
Patent OnlineTOCThe monitor allows you to know the total organic content in water at any time
High precision ion detector with low electrode constant design, compliant withASTMUnder the standardD1125-951999)Requirement, with temperature compensation function, and accurate to0.1℃.
4
Intelligent system management
Built in intelligent system, which can bring convenient and fast use. It can bring automatic system maintenance and exempt you from maintenance work. It can bring efficient system management, and the administrator and user settings ensure the stability of parameters.
MilliQ IntegralApplication scope of laboratory pure water and ultra pure water system:

1.Select0.2umWhen using terminal filters, the produced water is suitable forHPLCLC-MSMALDI-TOF-MSICICPAAWaiting for most analytical applications.

2.When selecting ultrafiltration columns, the produced water can be used for molecular biology applications (equivalent)DEPCProcessed pure water and cell culture.

3.SelectEDSWhen using columns, the produced water can be used for environmental analysisEDS(Endocrine interferon) research experiment.

4.The produced grade water is suitable for most basic laboratory applications, such as buffer and reagent preparation, microbial culture medium preparation, histology, dissolution experiments, and rinsing of glassware.

MilliQ IntegralTechnical indicators for water production of laboratory pure water and ultrapure water system

Milli-Q IntegralwithUS-EPAEPandWHOThe standard tap water refers to incoming water.

Elixwater

resistivity

>5MΩ.cm @25 °C

TOC

<30ppb (μg/l)

Note: If fromE-PODUsing pure water can achieve the following water quality indicators:

parameter

numerical value

Company

Bacteria

<1(*)

cfu/ml

grain

>0.2 μm < 1 (*)

Particulates /ml

pyrogen(endotoxin)

<0.001(**)

EU/ml

RNases

<0.01(**)

ng/ml

DNases

<4(**)

pg/μl

(*)During installationMillipak Express 40Filter orBiopakWhen using ultrafiltration columns as terminal refiners
(**)
During installationBiopakWhen using ultrafiltration columns as terminal refiners
The electrical resistivity of pure waterTOCConsistent with bacterial levelsISO3696ASTMD1193 (IIGrade resistivityTOCHBCsurfaceIindex)inIIGrade water andUSP ®EPRequirements for pure water.
Ultra pure water(IGrade water)Water Quality
(*)
During installationMillipak Express 40Filter orBiopakWhen using ultrafiltration columns as terminal refiners
(**)
During installationBiopakWhen using ultrafiltration columns as terminal refiners
Ultra pure water meets the requirementsISO3696ASTMD1193USP ®EPas well asCLSI ®- CLRWinIRequirements for grade water.
Milli-Q
water(fromQ-PODAccess)

parameter

numerical value

Company

resistivity

18.2

MΩ.cm @25°C

TOC

<5

ppb (μg/l)

Bacteria

<1 (*)

cfu/ml

grain

>0.2 μm < 1 (*)

Particulates/ml

pyrogen(endotoxin

<0.001(**)

EU/ml

RNases

<0.01 (**)

ng/ml

DNases

<4(**)

pg/ μl

Parameters of water production system
system>/pure water/Ultra pure water production(Max L/d/E-PODPure water production(L/min/Q-PODUltra pure aquatic water(L/min
Milli-Q Integral 3 70
the height is2.0 0.05-2.0
Milli-Q Integral 5 120
the height is2.0 0.05-2.0
Milli-Q Integral 10 240
the height is2.0 0.05-2.0
Milli-Q Integral 15 360
the height is2.0 0.05-2.0
quality assurance
Product Qualification CertificateProduct according toMilliporestrictQAProgram installation and testing
Verification certificateIncluding the built-in resistivity meter andTOCDetector
quality certificationIncluding all system consumables
POD Pak
verification—POD PakValidation of the effectiveness of removing specific target pollutants
ISO 9001v. 2000
andISO 14001Registered place of originIf necessary, certificates can be provided
CE
cULFC—To ensure the effectiveness and safety of the operation,Milli-Q IntegralThe system has been certified by safety and electromagnetic compatibility instructions.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!