Mini-Z Si Single wavelength X-ray Fluorescence Silicon Content Analyzer
Rigaku series
Product details

理学公司Mini-ZSi单波长X荧光硅含量分析仪

Reason for detection: Silicon has an adsorption effect on gasoline, which can cause mixed gases and affect the operation of the engine. What's even more serious is that the gum sticks to the valve, causing the piston to collide with the valve that hasn't returned to its original position when moving upwards, resulting in engine damage, etc! Impurities exist in the form of gum, and long-term use of inferior fuel can cause gum and substances that cannot be completely burned to accumulate in valves, intake ducts, and combustion chambers, gradually forming hard carbon deposits. It has an adsorption effect on gasoline, causing mixed gases and affecting engine operation. What's even more serious is that the gum sticks to the valve, causing the piston to collide with the valve that hasn't returned to its original position during upward movement, resulting in engine damage.

Therefore, internationally it is stipulated that the silicon content of finished gasoline and diesel is less than4ppm.

Hundreds of petrochemical companies and quality inspection departments in China have repeatedly demonstrated and strongly recommended their use.

Specially tested for the determination of total silicon content in gasoline, diesel, and condensate oil. Compliance with analysis method:SH/T0993ASTM D7757

Compact and user-friendlyMini-Z SiLaboratory analyzer is designed to detect ultra-low total in liquids and solidsSilicon content.Mini-Z SiProviding reliable analysis results for petrochemical enterprises with accuracy and precision beyond imagination.

Based onMWD XRFSingle wavelength dispersionXFluorescence technology,Mini-Z SiThe detection lower limit of the analyzer(LOD)Reachable0.2 ppmThis direct measurement method does not require sample conversion or high-temperature operation.

  Mini-Z SiInnovative design and low maintenance are the most ideal choices for laboratory and industrial process analysis.

Main features:
MWD XRF(Single wavelength dispersion)XFluorescence Total Silicon Analysis
Effective analysis scope of petrochemical products:0.5 ppm-5%
Testing time: 300Seconds, can also be set by the user
No consumables or high-temperature components
Ultra low maintenance volume
Modular design for plug and play maintenance
Start laboratory analysis

Repeatability:
Siconcentration standard deviation
2 ppm 0.2ppm
5 ppm 0.4 ppm
20 ppm 2.0 ppm
100 ppm 4.7 ppm