Multi parameter ventilation meter9555The series is a portable and handheld multifunctional ventilation testing instrument. These instruments can be equipped with differential pressure sensors and multiple wide range, plug-in probes. Users can choose the most suitable probe from a variety of probes with different functions according to their actual testing needs. Simply plug in the probe to achieve multiple tests. These probes can measure wind speed, temperature, relative humidityCOandCO2The parameters that can be calculated include air volume, heat flux, turbulence, wet bulb temperature, and dew point temperature. The probe can be ordered at any time, with a parameter list and traceable certificate attached. When calibration is required, simply return the probe for calibration, as calibration data is stored within the probe.
|
Optional probe for multifunctional ventilation meter
model | Probe description |
960 | Wind speed and temperature, direct probe |
962 | Wind speed and temperature, bendable probe |
964 | Wind speed, temperature, and humidity, direct probe |
966 | Wind speed, temperature, and humidity, bendable probe |
995 | diameter100mmThe impeller probe |
792 | Surface temperature probe |
794 | Air temperature probe |
980 | Indoor air quality probe |
982 | Indoor air quality probe, capable of measuringCO |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
1 When the temperature range exceeds5~65℃Afterwards, the wind speed measurement value needs to be corrected;
2 This accuracy refers to the measurement0.15~30m/sAccuracy of Time
3 less than5m/sIt is not recommended to measure the wind speed using a pitot tube. Pitot tubes are suitable for sizes larger than10.00m/sWind speed measurement. The range will change with the variation of atmospheric pressure
4 Accuracy is a function of the conversion rate from pressure to wind speed. When the actual pressure value increases, the conversion accuracy also increases.
5 The accuracy refers to the measurement of the ambient temperature25℃The accuracy of time needs to be increased after temperature changes0.03℃/℃The compensation
6 The accuracy refers to the measurement of the ambient temperature25℃The accuracy of time needs to be increased after temperature changes0.2% RH/℃The compensation includes1%The lag
7 The accuracy refers to the measurement of the ambient temperature25℃The accuracy of time needs to be increased after temperature changes± 0.36%/℃The compensation
8 This accuracy refers to the precision at the calibration temperature, which needs to be increased after temperature changes± 0.5%/℃The compensation
9 pressure limit=190 in. H2O(360 mmHg, 48kPa)
Specification List:
9555 | 9555-A | 9555-P | 9555-X | ||
Probe capable of measuring wind speed, temperature, and humidity | straight | Bendable | Optional | Optional | |
Stress testing | ● | ● | ● | ● | |
Calculate air volume, wet bulb temperature, and dew point temperature | ● | ● | optional | optional | |
Optional wind speed and temperature probes | ● | ● | ● | ● | |
Optional impeller probe | ● | ● | ● | ● | |
optionalIAQProbe (measurable)CO2Temperature, humidity, andCO) | ● | ● | ● | ● | |
Data collection (manual, automatic continuous saving) | ● | ● | ● | ● | |
Data Acquisition Software | ● | ● | ● | ● | |
Optional Bluetooth printer | ● | ● | ● | ● | |
CALIBRATION CERTIFICATE | ● | ● | ● | ● |