Shanghai Laibixin Instrument Technology Development Co., Ltd
Home>Products>NSA181/E/D/S Automatic Dry Wet Sedimentation Collector
NSA181/E/D/S Automatic Dry Wet Sedimentation Collector
NSA181/E/D/S Automatic Dry Wet Sedimentation Collector
Product details
Classification Overview:
There are three optional types of automatic precipitation sampler NSA 181 basic model, namely NSA 181/E, NSA 181/D,NSA 181/S, The difference lies in the number of sample collection bottles and the collection method, as shown in the following table:
type
Number of sample bottles
Sample bottle capacity (ml)
texture of material
heating
Precipitation distribution device
selection
NSA 181/E
1
5000 or 10000
HD-PE
Collection room heating
nothing
Used for mixing
Combined sampling
NSA 181/D
2
5000
HD-PE
Sample bottle bottom
Part heating
Yes, rotating head
Controlled electronically
Used for biweekly
Independent sampling
NSA 181/S
9×2
1000
HD-PE
Sample bottle bottom
Part heating
Yes, rotating head
Controlled by pulse
Used for 8 days
Independent sampling
NSA 181/HE, NSA 181/HD, NSA 181/HS are models that are equipped with snow covers on top of NSA 181/E, NSA 181/D, NSA 181/S, and are suitable for areas with heavy snowfall.
Instrument principle:
After the precipitation begins, the precipitation sensor RS 85 emits a pulse signal and opens the funnel to collect samples. Open the funnel, move the lid outward, rotate it to both sides, and then lower it to prevent aerodynamic interference with the sampling process. The precipitation collected in the funnel flows directly into the collection bottle (E-type) through the pipeline or into a circular funnel and then into the rotary head (D or S-type) through a hose. The rotary head is connected to each hard polyethylene sample bottle through a drainage pipe and a silicone hose. When the precipitation stops, the precipitation sensor RS 85 and an adjustable heating component send signals, and the motor drives to close the collection funnel.
For NSA 181/D or NSA 181/S, the precipitation collected by the funnel flows into a circular funnel through a pipeline and then into the rotary head through a hose. The rotating head is connected to a single hard polyethylene sample bottle through a drainage pipe and silicone hose. By SIEMENS ® LOGO ® Program control drives the motor to lift the annular funnel, and the collected precipitation flows into the sample bottle through the connected open rotating head's channel. If the external power supply is disconnected, all switch points will automatically connect. The battery will immediately provide power to the timing and rotating head control, supporting at least 24 hours of operation to ensure the replacement of sample bottles.
Standard configuration:
Double layer insulated PVC box
Polyethylene funnel
Electronic control components used to control the opening and closing of covers
Funnel and sample bottle heating device
Precipitation sensor RS 85
Optional configuration:
DURAN glass or Teflon plastic sample bottle
Duran glass or Quarz glass funnel
Optoelectronic precipitation sensor IRSS 88
Precipitation sensor NRS 80 or RS 85 OP, used in areas without snowfall
Snow cover (option "H", suitable for areas with snowfall)
PE or DURAN glass dry sample container
LCD timer
Data recording system
Base, made of galvanized steel material
Multiple signal circuit boards
element
category
NSA 181/E
NSA181/D
NSA 181/S
NSA 181/HE
NSA 181/HD
NSA 181/HS
funnel
Collection area
500 cm2
Precipitation sensor RS 85
Precipitation status
yes/no
open
moment
close
delay
Power Supply
input voltage
230V AC, 50 HZ
maximum power
270 W
370 W
cooling
×
Collection room heating
230V AC, 50 HZ, 100 W
×
×
230V AC, 50 HZ, 100 W
×
×
drive
Sealed funnel
Drive motor
24V DC, maximum 50 W
distributor
Drive motor
×
×
6 V CD
×
×
6 V CD
heating
RS 85 heating
24 V CD, 50 W
Funnel heating
24 V CD, 50 W
Sample bottle heating
×
24 V CD, 100 W
24 V CD, 100 W
×
24 V CD, 100 W
24 V CD, 100 W
Snow cover heating
×
24 V CD, 100 W
size
Height [mm]
950
Width [mm]
520
520
Depth [mm]
560
640
weight
Sampler [kg]
71
78
78
75
82
82
Base [kg]
16
14.6
work
height
Total height [mm]
(Base required)
1575
1675

The precipitation sampler is used to collect precipitation, and according to its own design and construction, it adopts one large capacity sample bottle or eight independent sample bottles for daily or weekly sample collection. After the experimental analysis and measurement are completed, each sample bottle can be easily removed from the equipment. Each measuring element inside the constant temperature isolation box of the equipment is made of chemically neutral materials. The box adopts an automatic ventilation design, which reduces the high temperature impact caused by strong solar radiation. The electronic control heating device for the funnel and sample bottle operates in winter. The direct material, funnel shape, and collection area comply with the recommended standards of VDI-3870 (VDI: German Institute of Engineers).
advantage:
Small instrument, module combination structure
Insulated PVC box body
High sensitivity precipitation sensor RS 85
A funnel with a collection surface area of 500 cm2
Selection of sample bottles suitable for multiple sampling modes
SIEMENS ® Technical electronic control
Electric heating system

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!