Natural gas online analyzer
The natural gas online analysis system mainly consists of gas supply system, sampling system, sample pretreatment system, online gas chromatograph, etc. The sample gas is taken out by the sampling system and enters the online gas chromatograph through the sample pretreatment system to remove impurities, oil, stabilize pressure, and stabilize flow. It passes through several parts such as the chromatographic injector, chromatographic column, detector, and data processing unit. After data processing, it is converted into a concentration signal and then transmitted to the remote flow computer for natural gas composition analysis.
instrumentcharacteristic
Small system size | Adopting Micro Electro Mechanical Systems (MEMS) technology, it has a compact and compact appearance, suitable for hazardous environments with explosion-proof requirements |
Low gas consumption | Adopting Micro Electro Mechanical Systems (MEMS) technology to effectively reduce the consumption of carrier gas and sample gas |
Stable gas flow control | Adopting precision pressure control technology to achieve precise control of carrier gas pressure and sample gas pressure, with a control range of (0-300) kPa and a control accuracy better than ± 0.05kPa |
The detector has high reliability | Adopting a dual channel microelectromechanical system micro thermal conductivity detector and an inert coating to protect the hot wire, it is suitable for harsh environments. At the same time, the detector adopts automatic protection technology, which will not damage the detector in the event of gas loss |
High integration degree | Adopting modular design to improve the maintainability of the system |
Strong environmental adaptability | By using online peak locking technology, the retention time of the analyzed object can be automatically adjusted, eliminating the drift of retention time caused by environmental changes or chromatographic column aging and other factors |
Equipment parameters
repeatability | ±2.0%FS |
zero drift | ±0.5%FS/day |
Span Drift | ±2.5%FS/day,3.0%FS/week |
linear | ±2.0%FS |
Sampling flow rate | 0.5-1.0L/min |
sample volume | 1cc × 2 or 0.1cc × 2 |
Use power supply | 115/220/230V,50/60Hz,2KW |
Including industrial computer data processors that can connect signals such as flow and temperature, | |
temperature control | |
Overheating protection: | If the actual temperature exceeds the set temperature by 20 ℃ or the furnace temperature exceeds 420 ℃, the heating system will automatically shut off |
Application Software functions | |
Real time data test chart display | |
Real time concentration value display | |
Measurement line setting | |
Real time trend chart display | |
Efficiency calculation analysis | |
reporting function |
Typical Customers
Long distance pipeline network: PetroChina, Sinopec
Urban gas gate station: a large city level gas company(Beijing Gas Group, Shenzhen Gas, Hangzhou Gas, Changchun Gas, etc)Group gas companies in first and second tier cities (China Gas, Ganghua, Xinao, CR, Kunlun)
LNGliquefy
Natural gas commercial users: natural gas power plants, natural gas chemical plants, etc
Typical applications
Application of energy metering in natural gas trade, such as long-distance natural gas pipelines and urban gas gate stations
Application of mixed refrigerant detection and analysis in natural gas liquefaction process, such as natural gas liquefaction
Application of natural gas composition analysis, such as natural gas power plants
on lineco2gas analyzer
Product Introduction
According to relevant national and industry standards for equipment in explosive gas environments, our company's explosion-proof gas analyzer series adopts a stainless steel material explosion-proof design, combined with safety barrier technology, strictly manufactured according to explosion-proof technical indicators, ensuring the safe use of explosion-proof instruments in industrial sites. Mainly solve the problem of gas in the customer's mediumCO2The content is analyzed by sampling and processing the sample gas data to ensure the normal measurement of the instrument.
Technical parameters:
CO2Measurement range(Measuring range) | 0-1000ppm/0-10%(Range optional) |
Resolution(Resolution ratio) | 0.01% |
Measurement accuracy(Accuracy of measurement) | ≤±2%F.S, or ≤±1%F.S(Imported instruments) |
Repeatability(Repeatability) | ≤±1%F.S |
Stability(Stability) | Zero drift: ≤ ±1%F.S/7dRange drift: ≤ ±1%F.S/7d |
Response time(Response time) | T90≤10S |
Preheating time(Preheating time) | ≤45min |
Sample gas flow rate(Flow of sample gas) | 1000±100mL/min |
Environmental humidity(Ambient humidity) | ≤90%RH |
Output signal(Signal output) | 4~20mA |
Communication mode(Communication mode) | RS232perhapsRS485(Communication protocol:Mod bus RTU) |
External dimensions(Shape size) | Long(650)*Wide(330)*High(350) |
Analysis principle(Analytical principle) | infrared |
Working power supply(Working power supply) | 100~240VAC 50/60Hz 1A |
Environmental temperature(Ambient temperature) | 0℃~+45℃ |
Environmental humidity(Ambient humidity) | ≤90%RH |
Output signal(Signal output) | 4~20mAperhaps0~5VDC |
Communication mode(Communication mode) | RS232perhapsRS485(Communication protocol:Mod bus RTU) |
Protection level(levels of protection) | IP65 |
Explosion proof grade(Explosive-proof grade) | ExdIICT6 |
Integration Description:
Cabinet material:304Stainless steel, equipped with pressure reducing heat tracing according to working conditions
Cabinet size: determined by configuration integration, available in indoor and outdoor types
Power Supply:220vor24vOptional or based on instrument configuration
The selection of integrated configuration is determined based on the operating conditions
Widely used in:
Used in petrochemical, natural gas, industrial gases, semiconductor industry, drying industry, food industry, power industry, mechanical manufacturingMeasurement of various gases in the manufacturing, air separation, and pharmaceutical industriesCO2Content analysis for natural gas decarbonization unitsCO2Content analysis.
Update time: September 1, 2020 8:54:02