Product details
- characteristic
◆ Non aerosol aerosol production - enhances biosafety (for mycobacteria, viruses) ◆ eliminates the risk of sample cross contamination
◆ Eliminates the complexity of traditional hand-held probe and fixed probe ◆ Very little foam
◆ Automatic power switch, no adjustment knob ◆ Can handle various samples, with a wide range of sample processing
◆ Suitable for various standard containers (PCR tubes, Eppendorf tube, 15mL Corning/Falcon tubes) ◆ capable of processing 12 samples at once
◆ Can be used to process trace samples up to 5L ◆ The automatic continuous rotation centrifuge tube makes the energy distribution of ultrasound more uniform
◆ Eliminates the complexity of traditional hand-held probe and fixed probe ◆ Very little foam
◆ Automatic power switch, no adjustment knob ◆ Can handle various samples, with a wide range of sample processing
◆ Suitable for various standard containers (PCR tubes, Eppendorf tube, 15mL Corning/Falcon tubes) ◆ capable of processing 12 samples at once
◆ Can be used to process trace samples up to 5L ◆ The automatic continuous rotation centrifuge tube makes the energy distribution of ultrasound more uniform
|
BIoruptor ultrasonic device
|
Probe type ultrasonic instrument
|
Applicability
|
Wide application range, can be applied to: ChIP assay, High throughput sequencer sample preprocessing, bacterial fragmentation, cell fragmentation, membrane protein extraction, homogenization, emulsification reaction
|
approve
|
Fragment size
|
DNA can be fragmented into ideal sizes, such as: ChIP assay: 300~500bp, High throughput sequencer: 150~250bp, High concentration of DNA fragments
|
The uncontrollable size of DNA fragmentation can easily generate large areas of smear DNA fragments
|
Sample rack
|
Various types of sample racks are available, including 0.5ml commonly used in experiments, 1.5ml, 15ml, 50ml centrifuge tubes paired with each other
|
not have
|
flux
|
High throughput, capable of processing 24 samples at once (UCD-400, 0.5ml sample rack)
|
Only one sample can be processed at a time
|
Sample result repeatability
|
Under the same experimental conditions, high repeatability ultrasound results can be obtained by using a rotating sample holder with high ultrasonic frequency
|
Low repeatability between samples
|
Interactive contamination between samples
|
Non probe sealed ultrasound method ensures no cross contamination of the sample
|
Probe type, if the probe cleaning is not complete, the samples are prone to cross contamination
|
safety
|
Closed tube ultrasound does not produce infectious flying mist, ensuring the safety of laboratory personnel and the environment
|
Need to open the tube for ultrasound, which can easily produce infectious flying mist
|
Sample bubble production
|
Completely non foaming, protein is not easily denatured, and will not degrade or harm the sample
|
High heat generation near the probe, easy bubble formation, and high possibility of protein denaturation
|
Suitable for precious samples
|
Capable of handling 5ul of samples, suitable for precious samples
|
If the sample is too small, the probe type ultrasonic instrument cannot be used
|
|
|
|
- parameter
UCD-200
|
Next Gen UCD-300
|
TWIN UCD-400
|
XL UCD-500
|
Single sink
|
Single sink
|
Double sink type
|
Single large sink
|
Number of samples that can be uploaded at once:
0.5ml: 12 samples
1.5ml: 6 samples
15ml: 6 samples
50ml: 3 samples
|
Number of samples that can be uploaded at once:
0.5ml: 12 samples
1.5ml: 6 samples
15ml: 6 samples
50ml: 3 samples
|
Number of samples that can be uploaded at once:
0.5ml: 24 samples
1.5ml: 12 samples
15ml: 12 samples
50ml: 6 samples
|
Number of samples that can be uploaded at once:
0.5ml: 48 samples
1.5ml: 24 samples
15ml: 24 samples
50ml: 12 samples
|
Plastic noise resistant speaker
|
Metal anti noise speaker with excellent sound insulation effect
|
Metal anti noise speaker with excellent sound insulation effect
|
Metal anti noise speaker with excellent sound insulation effect
|
Rotary timer (analog)
|
Digital Timer
|
Digital Timer
|
Digital Timer
|
_
|
Equipped with overheat automatic protection device
|
Equipped with overheat automatic protection device
|
Equipped with overheat automatic protection device
|
L. M, H three power options
|
L. Two power options for H
|
L. M, H three power options
|
L. M1, M2, H four power options
|
Main functions:
DNA, chromatin shearing
|
Main functions:
DNA, chromatin shearing
|
Main functions:
DNA, chromatin shearing
|
Main functions:
Cell lysis
|
- accessory
- application
1. Wide application range: can be applied to: ChIP assay, High throughput sequencer sample pre-processing, homogenization, bacterial fragmentation, cell fragmentation, membrane protein extraction, emulsification reaction, etc
2. Fragment size: DNA can be fragmented into ideal sizes, such as: ChIP assay: 300~500bp, High throughput sequencer: 150~250bp, High concentration of DNA fragments
3. High throughput: 6-12 samples can be processed at once
4. Sample rack: Various types of sample racks are available, including 0.5ml commonly used in experiments, 1.5ml, 15ml, 50ml centrifuge tubes paired with each other
5. High repeatability of sample results: By rotating the sample holder while ultrasound, highly reproducible ultrasound results can be obtained under the same experimental conditions
6. Avoid cross contamination between samples: Due to the use of a probe free closed ultrasound method, the samples will not cross contaminate
7. High safety: ensuring the safety of laboratory personnel and environment, closed tube ultrasound, no infectious flying mist produced
2. Fragment size: DNA can be fragmented into ideal sizes, such as: ChIP assay: 300~500bp, High throughput sequencer: 150~250bp, High concentration of DNA fragments
3. High throughput: 6-12 samples can be processed at once
4. Sample rack: Various types of sample racks are available, including 0.5ml commonly used in experiments, 1.5ml, 15ml, 50ml centrifuge tubes paired with each other
5. High repeatability of sample results: By rotating the sample holder while ultrasound, highly reproducible ultrasound results can be obtained under the same experimental conditions
6. Avoid cross contamination between samples: Due to the use of a probe free closed ultrasound method, the samples will not cross contaminate
7. High safety: ensuring the safety of laboratory personnel and environment, closed tube ultrasound, no infectious flying mist produced