Olympus Microscope BX53M
Details
1.productpurpose:
With the development of various fields such as science and engineering, the demand for microscopes is becoming increasingly diverse. Olympus divides microscopes into different combination units based on their functions to meet the diverse needs of users. According to the purpose of the product, the main base of the microscope platform can be divided intoAH, BH, and CH series. The era of combining units and manufacturing microscopes that meet user needs has arrived.
2.productcharacteristic:
BX3M has adopted a new encoding function that integrates the hardware settings of the microscope with the Olympus Stream image analysis software. The observation method, illumination intensity, and objective position are all recorded in the software and/or manual controller. The encoding function enables the microscope settings to be automatically saved with each image, making it easier to restore the settings later and provide document records for reports. Not only does it save the operator's time, but it also minimizes the probability of using incorrect settings to the greatest extent possible. The current observation settings are always clearly displayed on the manual controller and software
● Comprehensive customizability: Modular design allows users to flexibly build systems that meet their specific requirements.
●During initial installation, the lighting intensity can be adjusted to match the coded lighting fixture/Or match the specific hardware configuration of the encoded objective lens converter.
● Intuitive microscope control is comfortable and easy to use: Microscopic examination tasks often require a long time to adjust microscope settings, acquire images, and make necessary measurements to obtain satisfactory reports. Users sometimes need to invest time and money to complete professional microscope training, or only understand a small part of the full functions of the microscope before starting work.
BX3M simplifies complex microscopic examination tasks through its excellent design and convenient control functions. Users do not need long training to master most of the functions of the microscope. BX3M's convenient and comfortable operation also improves image reproducibility, minimizing human errors to the greatest extent possible
●Humanization is crucial for all users. Whether it's a standalone microscope user or an integrated OlympusUsers of Stream image analysis software's microscope system can benefit from a user-friendly manual controller that can clearly display the location of microscope encoded hardware. Simple manual switch allows users to focus their time on the sample itself and the required inspections to be carried out.
●Currently, only the manual loading platform is being movedThe XY knob allows for convenient and quick image stitching, eliminating the need for an electric stage.
OlympusStream software uses pattern recognition technology to generate panoramic images, providing users with a wider field of view than a single image.
●OlympusThe Depth of Field Extended Imaging (EFI) feature of Stream software can capture sample images with heights exceeding the depth of focus of the objective lens, and overlay them together to create a super depth of field image. EFI can be performed using manual or electric Z-axis mechanisms, and a height map can be created to easily identify the structure. You can also create EFI images offline using Stream desktop version.
BX3M provides high-intensity white LED light sources for both reflected and transmitted light illumination. LED provides efficient and long-lasting lighting, making it an ideal tool for materials science testing applications.
●Automatic calibration: Similar to digital microscopes, using OlympusStream software can also implement automatic calibration. Can obtain more reliable measurement results.
3.major function
●Perfect scalability to meet various needs:In addition to the integrated bright field observation components, various other modular components such as fluorescence, phase difference, polarization, dark field, etc. can be added to improve the scalability of the system. use100W halogen lamp projection lighting source can meet various imaging and observation methods
●Customizable control layout:BX53 has won a very flexible layout design, with a light intensity adjustment knob in the middle position and a fluorescent lighting shutter that can be controlled by both hands. UV and fine tuning knobs can be installed on either side of the microscope's left or right hand according to user preferences.
●Fluorescence observation is more comfortable:All Olympus fluorescent filter components use ultra-high performance color filtersFluorescent lighting pillars can be installed8 color palettes, capable of imaging multiple stained specimens simultaneously, can be replaced without the need for tools.
●Energy saving switch:Capable of automatically turning off the light source,The operator has left beyondAfter 30 minutes, the microscope will automatically turn off the transmitted light source. The skill of turning on and off the machine saves energy and protects the service life of the light source.
●Fluorescence observation:High contrast phase contrast images allow for close observation of the interior of cells and live bacteria. useUPLFLN-PH or PLN-PH series objective lenses are capable of phase difference observation from 10X to 100X. By using the U-PCD2 phase contrast/dark field spotlight, users can observe the reflected fluorescence imaging of the specimen.
●Polarization observation:High resolution imaging of birefringent structures allows observation of teeth, bones, muscles, nerve tissues, myosin fibers, and mitotic spindles without staining. Middle Attachment(U-OPA/U/CPA) is used for positive image inspection and positive image/cone vision inspection. A wide range of optical path differences can be observed through various compensators. At the same time, it is possible to choose a spotlight specially designed for polarized observation, an objective turntable, a rotating stage, an objective lens, a simple polarizing accessory, and a polarizer for detecting uric acid crystals.
●Dark field observation:Perfect dark field observation effect from low magnification to high magnification, selected fromDry dark field condenser U-DCD from 10X to 100X or oil type condenser U-DCW from 20X to 100X.
4. Working conditions
● Indoor use,Ambient temperature: 5 ℃ to 40 ℃ (41 ° F to 104 ° F)
Maximum relative humidity: 80% at heights up to 31 ℃ (88 ° F), linearly decreasing to 70% at 34 ℃ (93 ° F), and 60% at 37 ℃ (99 ° F)
arrive50% relative humidity at 40 ℃ (104 ° F)
Power supply voltage fluctuation: not exceeding ± 10% of normal voltage
5.Technical parameters:
optical system |
UIS2 Infinite Distance Optical System |
focus |
Vertical moving stage: The stage has a stroke of 25mm and is equipped with a coarse belt adjustment limiter. The coarse adjustment knob can adjust the torque. |
The installation position of the stage can be changed, with a highly sensitive fine adjustment knob (minimum focusing accuracy: 1 micron) |
|
Illuminator |
Built in transmissive Kohler lighting fixture, light intensity preset button, light intensity LED display, |
Built in color filters (LBD-IF, ND6, ND25, and an optional slot) |
|
12V 100W halogen bulb (pre aligned). |
|
objectiveturntable |
Removable 5-hole/5-hole coding/6-hole/7-hole/7-hole coding objective disc |
converter |
Light dark field 5-hole converter, light dark field 6-hole converter |
Bright Field 6-Hole Converter, Bright Field 7-Hole Converter |
|
observing tube |
Wide field of view (22 fields of view) |
Ultra wide field of view (26.5 fields of view) |
|
stage |
Ceramic surface coaxial stage with left-hand or right-hand low position drive device; Equipped with a rotating device and a torque adjustment device. Optional rubber handle (can provide accessibility, groove, coaxial, flat, rotatable stage) |
condenser |
Abbe spotlight (N.A1.1), Used for 4X-10Ox Swinging achromatic spotlight (N.A.0.9), Used for 1.25X-1OOx (after shaking: 1.25X-4X) Anti chromatic aberration and anti spherical aberration spotlight (N.A.1.4), Used for 1OX-10Ox Phase difference/dark field spotlight (N.A.1.1), phase difference: for 10X-10Ox, dark field: for 10X-10Ox (N.A. can reach 0.8O) Universal spotlight (N, A.0.9), Used for shaking out 1.25X-10Ox: 1.25X-4X, oil type top lens: (N,A.1,4) Low magnification condenser lens (NA.0.75), used for 2X-10Ox (dry mirror) Ultra low magnification spotlight (N, A.0.16), Used for 1.25X-4X Dark field dry condenser lens (N.A.O.8-0.92), used for 10X-1OOx Dark field oil type spotlight (N.A, 1.20-1.40), used for 1OX-1OOx |
fluorescent illuminator |
Economy type (F.N.26.5,8-hole color filter disc) |
fluorescent light source |
100W color corrected mercury lamp chamber and power supply, 100W ordinary mercury lamp chamber and power supply, 75W xenon lamp chamber and power supply |