TBD5 DS1390 seriesOnline liquid density transmitter Beidou Star density detector
Product characteristics
*The packaging structure and optimized circuit design fundamentally eliminate the interference components of traditional density transmitter signal output, ensuring the sensitivity and stability of measurement and output signals; Can work with recorders DCS, PLC, and other control systems are connected to maximize the elimination of nonlinear errors caused by liquid level fluctuations, installation, and other factors. It can measure various slurry media such as mud, sewage, chemical agents such as acid and alkali, oil, wine, milk, etc., and is suitable for measurement and control in fields such as petroleum, chemical, metallurgy, mining, water conservancy, urban and hydrological exploration.
HMI
The BD5xMD transmitter comes with a 2x16 character LCD display driver interface, which can be plugged in with the accompanying keyboard for various operations and calibrations without the need for a microcomputer. Users can modify parameters or perform various related operations at any time.
English window prompts for setting and calibration process. Technicians can perform * work without consulting manuals.
Data processing function
Professional testing module for main parameters and related parameters
Common application control system programs, application system configuration functions
Commonly used numerical processing modules. Smooth processing parameters and data averaging modes (hourly, fixed-point, etc.) can be set for selection
Built in temperature correction mode.
Historical data records (daily schedule/365 days/month/quarter/year)
Instrument electrical function
Real Time Clock
1-channel 0/4 to 20mA analog signal output, which can represent linear test signals or be used for analog control output. The signal amplitude and corresponding values can be set arbitrarily;
Supports IEEE1451.1 NCAP as an input/output port for network controllers;
RS232 communication interface;
RS485 remote communication interface, optional. The speed can be set. Can be used to connect measurement and control devices or other computer communication or organizational instrument network systems;
2-channel field-effect open circuit 5V switch for ground collector. Used for alarm driving or switch control.
1 optical coupling isolation circuit circuit circuit switch, 0-220 AC/1A. Used for alarm driving or switch control; 0/4 to 20mA analog signal output, which can represent linear test signals or be used for analog control output. The signal amplitude and corresponding values can be set arbitrarily;
TBD5 DS1390 seriesOnline liquid density transmitter Beidou Star density detector
Technical specifications of transmitter
Environmental temperature for use |
-20 ~ 60ºC |
Environmental humidity for use |
0-95% RH (no condensation) |
storage temperature |
-51 to 125°C |
Storage humidity |
0-90% RH (no condensation) |
power supply |
12/24 V DC ±20% |
Total power consumption: |
<100mW |
Explosion proof grade: |
Ia, Intrinsic safety design. Can be used for Class 1, Group A/B/C/D; Class II, Group E/F/G environment; |
weatherability |
NEMA 7, NEMA 8, NEMA 9,NEMA 6/6p,IP67 |
size |
Zui deep immersion size: L xx cm as shown in the table below; Zui small intrusion size: S xx cm as shown in the table below; |
Installation method |
Top installation, vertical and horizontal plane |
Connection method |
PN0.25DN65 Blue (Blue diameter 185mm, bolt hole position 130, Æ 14x4); Special needs can be ordered |
Technical specifications of transmitter
05S30L115 |
05S60L230 |
10S30L115 |
|
Test range |
0.6~3.000g/cm3 |
0.3~1.500g/cm3 |
1.20~6.00g/cm3 |
repeatability |
±0.02%FS |
±0.02%FS |
±0.02%FS |
accuracy |
<±1.0% |
<±1.0% |
<±1.0% |
response time |
<100ms; |
<100ms; |
<100ms; |
operation temperature |
-40 to 85°C, max<125°C |
-40 to 85°C, max<125°C |
-40 to 85°C, max<125°C |
Working pressure |
<0.0345, (Max <0.1) MPa |
<0.0345, (Max <0.1) MPa |
<0.069 (Max <0.21) MPa |
Contact materials |
316SS or 304 |
316SS or 304 |
316SS or 304 |
Long term stability |
± 1% for 1 year |
± 1% for 1 year |
± 1% for 1 year |
Effective detection length SL |
30cm |
60cm |
30cm |
Zui High Liquid Level TL |
115cm; |
230cm; |
115cm; |
Zui low liquid level LL |
35cm; |
65cm; |
35cm; |
Insertion depth E |
Standard: 30cm; |
Standard: 60cm; |
Standard: 30cm; |
Inserting Dimensions |
Center f70, eccentricity f60 |
Center f70, eccentricity f60 |
Center f70, eccentricity f60 |
application |
Measurement of liquid density in open containers The requirement for the bottom probe to reach the highest liquid level is<115cm; The two probes must always be in the liquid; |
Measurement of liquid density in open containers The requirement for the bottom probe to reach the highest liquid level is<230cm; The two probes must always be in the liquid |
Measurement of liquid density in open containers The requirement for the bottom probe to reach the highest liquid level is<115cm; The two probes must always be in the liquid |
Sealed containers require special ordering |
Sealed containers require special ordering |
Sealed containers require special ordering |
*The range can be adjusted using LS
Specification and model
TBD5 DS1390-xxS(SL)L(TL)-Exx-x
The TBD5 DS1390 series is professionally developed and produced by the Beijing Beidouxing Industrial Chemistry Research Institute, while providing front-line services for our customers!