Online low turbidity monitoring system
Brief introduction: The online low turbidity detection system AQT1A0 meets or exceeds the USEPA Method 180.1 standard, pre calibrated (no on-site cali
Product details
Details introduction:

The online low turbidity detection system can be used for high-precision turbidity measurement in drinking water. This system can be directly connected to PLC to achieve seamless integration with industrial control systems. Any computer can be used to display data, calibrate, and customize measurement systems. Report data using standard current loops and optional relay alarms. Using a smaller volume according to Formazin standards to save calibration costs; Save space, time, and cost.

In the application of turbidity in drinking water, DataStick uses pre calibrated plug-in optical detectors. DataStick is inserted into a sampling chamber specifically designed for measuring water turbidity.

The sampling chamber removes foam from the water so that solid particles can be detected. The lamp in the sampling room provides 3 years less collimated white light and is easy to replace at the top of the sampling room.

Because the sampling chamber is only 135ml, only a small amount of Formazine is needed to complete EPA calibration.

The TDW38 drinking water turbidity system is part of the DataStick product family. DataStick can use any sensor probe manufactured by AquaSensors and can directly communicate with industrial computer systems using the provided communication adapter. AquaSenors AV38 on-site display is a standard requirement for this turbidity system. If AV38 is not required, any number of turbidity systems can be digitally networked to a single computer interface. Calibration, setup, diagnosis, and measurement can be performed using open protocol commands.



Power requirements (requiring Class II DC power supply):
Voltage range: DC 24V
*High power: 8W when using AV38 DataStick and light source
Typical power: 6W when using AV38 DataStick and light source

Structure:
Light source: White light (tungsten wire)
Sampling room material: ABS plastic
Sampling room volume: 135ml
Light source bracket: anodized aluminum
Base plate: 12 x 12 inches, 4 mounting holes
Sensor probe material: quartz glass, anodized aluminum
Weight:
5.6 pounds=2.6kg

Measurement unit:
Measurement unit: NTU
Temperature units: Celsius, Fahrenheit

Calibration:
Sample: 1 point