In our country,VOCs (volatile organic compounds) refer to organic compounds with a saturated vapor pressure greater than 70 Pa at room temperature and a boiling point below 260 ℃ at atmospheric pressure, or all organic compounds with corresponding volatility at a vapor pressure greater than or equal to 10 Pa at 20 ℃. Mainly including various aliphatic and aromatic hydrocarbons, alkenes, oxygen-containing hydrocarbons, and halogenated hydrocarbons, etc
Detailed Introduction
national standard
stem or root of plantsinstrumentMeets the following national standards
Industry standards |
| Vocs monitoring object |
integrated emission standard of air pollutants | GB/16927-1996 | Benzene, toluene, xylene, phenols, formaldehyde, acetaldehyde, acrylonitrile, methanol, aniline, chlorobenzene, nitrobenzene, vinyl chloride, non methane total hydrocarbons |
Emission Standards for Volatile Organic Compounds in Surface Coating (Automotive Manufacturing Industry) | DB32/2862-2016 | Benzene, toluene, xylene, benzene derivatives TVOCs |
Technical requirements and detection methods for continuous monitoring system of non methane total hydrocarbons in fixed pollution source exhaust gas | HJ/1013-2018 | Non methane total hydrocarbons |
Technical requirements and detection scheme for continuous monitoring system of volatile organic compounds in ambient air by gas chromatography | HJ/1010-2018 | Volatile Organic Compounds |
Indoor decoration materials - Formaldehyde emission limit in artificial boards and their products | GB 18580-2017 | formaldehyde |
Test methods for physical and chemical properties of artificial boards and decorative artificial boards | GB/T 17657-2013 | formaldehyde |
Sampling and determination methods for volatile organic compounds and aldehydes and ketones in vehicles | HJ/T 400-2007 | Organic compounds, acid ketones |
Technical requirements and detection methods for portable detectors of total hydrocarbons, methane and non methane total hydrocarbons in ambient air and exhaust gas | HJ/ 1012-2018 | Total hydrocarbons, methane, non methane total hydrocarbons |
TECHNICAL INDEX
project | HJ1013-2018 Technical Requirements and Testing Methods for Continuous Monitoring System of Non Methane Total Hydrocarbons in Fixed Pollution Source Waste Gas | HJ1012-2018 Technical Requirements and Testing Methods for Portable Monitoring Instruments for Total Hydrocarbons, Methane, and Non Methane in Environmental Air and Waste Gas | HJ1010-2018 Technical Requirements and Detection Methods for Continuous Monitoring System of Volatile Organic Compounds in Environmental Air by Gas Chromatography | ||
| Fixed pollution source exhaust gas NMHC-CEMS laboratory testing project | Fixed pollution source exhaust gas NMHC-CEMS on-site testing project | Type I instrument | Type II instrument | / |
Analysis cycle (system analysis cycle) | ≤2 min | ≤3min | ≤2 min | / | |
Instrument detection limit (system detection limit) | ≤0.8 mg/m3 | / | ≤0.13 μmol/mol | ≤1.49μmol/mol | ≤0.1 nmol/mol |
Repeatability (relative standard deviation) | ≤2% | / | ≤ 2.0% (methane) | / | |
linearity error
| ±2%F.S. | / | Not exceeding ± 2.0% F.S. (methane) | / | |
24-hour drift | ±3%F.S. | Not exceeding ± 3% F.S | / | Not exceeding ± 1nmol/mol | |
The impact of environmental temperature changes | ±5%F.S. | / | Not exceeding ± 5.0% F.S | / | |
The impact of changes in injection flow rate | ±2%F.S. | / | / | Not exceeding ± 2.0% F.S | / |
The impact of changes in power supply voltage | ±2%F.S. | / | The variation of power supply voltage is ± 10%, and the variation of all measured components of the instrument shall not exceed ± 2.0% F.S. | / | |
The influence of oxygen | ±2%F.S. | / | Not exceeding ± 5.0% F.S | / | |
Conversion efficiency | Not less than 95% | / | ≥95% | / | |
parallelism | Not exceeding 5% | / | ≤5.0% | ≤20% |
Technical performance:
control mode | Embedded industrial control computer |
Drift/repeatability | ±1%~±5% |
Sample gas flow rate | 50ml/min |
Sample gas pressure | 0.1MPa |
Sample gas interface | 1/4 "Swagelok SS |
Carrier gas type | N2/H2/Ar/He |
Carrier gas interface | 1/8 "Swagelok SS |
carrier gas flow | 150ml/min |
Carrier gas pressure | 0.4 MPa |
Display | LED |
Power supply | AC220V,50~60Hz |
Power | 400W |
Weight | 20Kg |
Size | Standard 5U rack mounted chassis |
482mm(W)×222mm(H)×400mm(D) | |
Flow control of carrier gas and sample gas | Electronic monitoring |
communication interface | RS-232/485 |
Communication protocol | modbus |
Overall layout