VIP member
Online optical dissolved oxygen sensor, specialized fluorescence method for dissolved oxygen in aquaculture
Online optical dissolved oxygen sensor, specialized fluorescence method for dissolved oxygen in aquaculture
Product details

Characteristics of Fluorescence Dissolved Oxygen Sensor
- Digital sensor, RS485 output, supports MODBUS
- No film, no electrolyte required, no interference, no need for frequent calibration
- No oxygen consumption, no flow rate limitation
- Tailored specifically for the aquaculture market, with ultra-high cost-effectiveness
name | Specialized fluorescent dissolved oxygen sensor for aquaculture |
model | HLR-505-A |
Measurement principle | fluorescence |
Range of measurement | 0~20mg/L or 0~200% saturation |
accuracy | 3% |
response time | 60 S |
sensor drift | <3% per year |
temperature sensor | NTC |
temperature range | 0 ~ 50℃ |
Temperature Accuracy | ±0.5℃ |
protection grade | IP68 |
Maximum operating pressure | 6bar |
sensor interface | Supports RS-485 and MODBUS protocols |
assemble | M22*1.5mm |
power information | DC 6~12V, Current<50mA |
Sensor Size | Φ22*188.3 |
Probe cable length | 10 meters (default), customizable |
calibration | One or two point calibration |
Fluorescent cap lifespan | Guaranteed use for one year (under normal use) |
Shell material | 316L |
Online inquiry