Nanjing Kelunde Scientific Instrument Co., Ltd
Home>Products>Optional functional modules
Optional functional modules
BSTR10A converter module; BSTR2A converter module; ADC10M ultra fast sampling module; SCAN250 analog linear scanning module; MUX sequence testing modu
Product details

1. BSTR10A Converter Module

oAn external functional component;
Used to increase the maximum current range, it can be increased to10AThe response voltage drops to20V);
Applicable toPGSTAT302NPGSTAT128NandPGSTAT100N.

oapplication area
High power power battery;
Fuel cell;
Supercapacitors;
Research on high current corrosion;
Electrolysis and Metallurgy

Ordering Information
● BSTR10A.x 10Ampere amplifier (suitable for)PGSTAT302NandPGSTAT128N
● BSTR10A. PG100.x 10Ampere amplifier (suitable for)PGSTAT100N



2.BSTR20AAmplifier module


Main functions and features
An external functional component;
Used to increase the maximum current range, it can be increased to20AThe response voltage drops to20V);
Applicable toPGSTAT302N.

application area
High power power battery;
Fuel cell;
Supercapacitors;
Research on high current corrosion;
Electrolysis and Metallurgy

Ordering Information
● BSTR20A.x 20Ampere amplifier (suitable for)PGSTAT302N



3.ADC10MUltra fast sampling module


Main functions and features
A built-in functional module;
The sampling frequency can be increased to10MHzThat is100nanosecond/Point;
WithSCAN250When used in conjunction with functional modules, it can achieve up to250 kV/sCyclic voltammetry measurement;
Applicable toPGSTAT128NPGSTAT302NPGSTAT100N.



4.SCAN250Analog linear scanning module



Main functions and features
A built-in functional module;
Can provide simulated linear potential signals for true linear scan cycles and linear scan voltammetry, replacing the step scan in standard instruments;
The total sum of measurable capacitive current (double-layer charging current) and Faraday current can avoid incorrect results obtained by stepwise cyclic voltammetry in studying rapid adsorption and desorption processes;
WithADC10MWhen functional modules are used in combination, the scanning rate of cyclic voltammetry can be as high as250 kV/s
Applicable toPGSTAT128NPGSTAT302NandPGSTAT100N.

application area
Research on ultra fast adsorption and desorption processes;
Research on ultra fast electron transfer reactions;
Ultra fast in vivo bioelectrochemical detection, etc.


5.MUXSequence testing module


Main functions and features
Used for sequentially measuring multiple electrochemical cells or multiple working electrodes;
Applicable toPGSTAT204PGSTAT128NandPGSTAT302N

Three types:

1. MUX.MULTI4Can be connected4Perform sequence testing on up to one electrolytic cell, which can be connected at most64An electrolytic cell.

2. MUX.SCNR16Can be connected16Perform sequence testing on a single working electrode, sharing the counter electrode and reference electrode.

3. MUX.SCNR8Sequential measurement8A working voltage.

application area
Measurement of multiple corrosive samples;

Measurement of multiple battery samples;


6.ECDSmall current amplification module


Main functions and features
A built-in functional module;
Used to expand the low current range, the current range is:100pA ~ 100 μA
The current resolution is improved from the original30 fARaise to0.3 fA
Built in three levelsSallen-KellyFilter, capable of filtering measurement noise;
Applicable toPGSTAT128NPGSTAT302NPGSTAT100Three types of instruments.

application area
Measurement of microelectrodes and ultramicroelectrodes;

Ordering Information
● ECD.xSmall current amplification module


7.BADual potentiostat module


Built in module

Main functions and features
A built-in functional module that provides the function of connecting a second working electrode;
Can apply fixed potential or scanning potential;
Usually with rotating disk ring electrode system(RRDE)Continuous use;
Applicable toPGSTAT128NPGSTAT302NPGSTAT100Three types of instruments.


useBADouble potentiostat module, curve of simultaneous potential scanning of the second working electrode

Main technical parameters

Maximum current:±50 mA

Current range:10nA ~ 10 mA

Bias potential:±10 V

Ordering Information
● BA.xDual potentiostat module


8.ECNElectrochemical noise module


Built in module

Main functions and features
A built-in functional module;
Measurable electrochemical noise, including potential noise and current noise;
Timely observation of the average and standard deviation of potential noise and current noise;
Applicable toPGSTAT128NandPGSTAT302N.


Multiple analysis methods

application area
Can be used for pitting corrosion research

Ordering Information
● ECN.xElectrochemical noise module



9.FI20Filter integrator module


Built in module

Main functions and features
A built-in functional module;
It can directly control the power level instead of current control;
Cyclic voltammetry and step tests for controlling electrical quantities;
Built in one three timesSallen-KellyFilters can be used to filter out noise;
Usually used in conjunction with microelectrodes and ultramicroelectrodes;
Applicable toPGSTAT128NPGSTAT302NPGSTAT100Three types of instruments.

Main technical parameters
Integral time range:10ms100ms1s10s

Ordering Information
● FI20.xFilter integrator module



10.pX1000modular


Built in module

11.

Main functions and features

A dedicated tool for conductingpHThe module for measuring values or double constant potentials, whenpHWhen electrodes or ion selective electrodes are connected to the module,pH11.The value or ion concentration signal can be input as a second signal onto the recording curve, and this second signal can be used for electrical titration experiments.

Ordering Information
● pX1000.x pX1000modular



11. Turbocharger module

Main functions and features
● VOLT. MULTTurbocharger is used to adjust the control potential from±10VRaise to±30VThe measured voltage can reach100V. (Applicable to)PGSTAT302N

Ordering Information
● D.VOLT. MULTTurbocharger module


12.Voltage divider module

Main functions and features
● HIGH. VOLT.DIVVoltage divider is used to increase the measured voltage in constant current mode to100V.

Ordering Information
● D.HIGH. VOLT.DIVVoltage divider module


13.Dynamic load interface

Main functions and features
● LOAD. INTThe dynamic load interface is used to convert the DC signal generated by the potentiostat intoFRAThe AC signal generated by the signal generator is superimposed and transmitted to the load.

Ordering Information
● D.LOAD. INTDynamic load interface



14.EQCMQuartz crystal microbalance module



Main functions and features

Composed of an internal connection module and other external measurement modules;

● EQCMThe electrochemical quartz crystal microbalance module measures the mass change per unit area on the surface of the crystal oscillator by recording the change in resonance frequency of the crystal oscillator. Crystal oscillators can be placed in atmospheric, vacuum, or liquid environments. This module is capable of measuring sub micrograms per square centimeter of mass change;● EQCMThe standard configuration of the module already includes the matching electrochemical cell and two pieces6MHzThe crystal oscillator. about6MHzThe crystal oscillator,1HzThe frequency variation is approximately equivalent to10ng/cm2Quality changes. The supporting electrochemical cell already includes a counter electrode, a reference electrode, and a temperature sensor;

The software can display both electrochemical curves and mass change curves simultaneously;

Applicable toPGSTAT128NPGSTAT302NTwo types of instruments.

Main technical parameters
Oscillation frequency:6MHz
resolving power:0.07Hz
Relative accuracy:1Hz
Sampling rate:50S/s

Ordering Information
● EQCM.xQuartz crystal microbalance module



15. Optional Accessories

1)AUT-Rotating Ring-Disk ElectrodeRotating ring electrode

oMain functions and features:

o1.Speed range:0-10000rpm(Charged electrode head),Stepping1rpmAcceleration4000rpm/second
2.The speed can be manually controlled or adjusted throughAutolabOr other brands of potentiometers for control
3.Built in photoelectric system for measuring rotational speed, providing closed-loop control of rotational speed, even in10000rpmAt high speeds, the deviation between the set speed and the actual speed still does not exceed2rpm
4.Contact method: Double sealed mercury tank. Using liquid mercury as the conductive medium during the rotation process, it has the characteristics of stable speed, low noise, and maintenance free (no need to replace carbon brushes regularly)
5.The rotating part is inside the electrolytic cell, which can maintain the sealing of the entire system during the rotation process
6.RRDEandRDEElectrode tips are interchangeable
7.RRDETypes of electrode tips:Pt/PtAu/PtandGC/Ptetc.
8.Maximum current500mA
9.Electrode head collection efficiency24.9%
10.RRDEGap between electrode head disk and ring:375μm
11.The entire rotating electrode structure is compact, occupying much less space than other similar products, and can be easily placed in a glove box

oapplication area
>Characterization of electrocatalytic intermediate processes
>Characterization of intermediate processes in electrodeposition, etc

oOrdering Information
> AUT.RRDEAutolabRotating ring electrode

2Flat electrolytic cell

3) Capacity1LEquipped with Lu Jin capillary tube, stainless steel counter electrode, and water bath constant temperature device. Used for corrosion research.

4) MasterTo have functions and features

>A rotating disk electrode system with high mechanical stability ensures good reproducibility.

>Using liquid mercury as a medium to further reduce motor operating noise.

>Equipped with onePCTFEElectrode sleeve, convenient for replacing electrode heads of different materials, can be matched with various working electrode heads, including glassy carbon, silver, platinum, and gold electrodes;

>adoptGPESSoftware, rotation speed range increased to100~10000 rpmMeet the requirements of higher speed and lower noise.

>WithAutolabWhen the potentiostat is connected, it can be usedGPESThe software can perform stepless speed regulation.

>Equipped with dual salt bridge reference electrodes, it is easy to change the internal and external reference electrolytes.

application area
>Replacing suspended mercury electrodes: can replace traditional mercury working electrodes, such as in voltammetry or cyclic voltammetry.

>Electrochemical analysis of electrode reaction kinetics.

>Trace analysis: In soluble mercury salt solutions, a mercury film will deposit and form a mercury film electrode. Compared to suspended mercury electrodes, electroactive media cannot diffuse into a relatively large system, while mercury film electrodes can diffuse due to their thickness of only a few millimeters. During the process of heavy dissolution, the sediment is further oxidized, resulting in a larger peak and lower detection limit.








Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!