CPT2620AT-E25Oxygen concentration transmitter
Conditions of Use
Gas background: CO2,O2,N2,HCl;
pressure:atmospheric pressure±50%;
temperature: :- 20~60°C ;(-5~40°C compensated)
humidity: 15-90%RH,There should be no condensation;
Technical Parameter:
Range: 0-100%
repeatability: 0.1%;
Linearity: <±1%;
response timeT90: <12s (@20%)
drift: < 20% /5year;
If optional display is required :XM3.5-1alarm
A transmitter and an alarm can form a point detection alarm system.
Configure the specific number of sets as needed.
pay attention to:If the oil mist condenses,Possible loss of sensor response;Suggest providing detailed process parameters,Choose when necessaryCGA2620-O2continuous analyzer.
Sulfur dioxide transmitter
CPT2610-AT-SO2AE-R5000ppmSulfur dioxide transmitter
Standard range: 0-2000ppm;Can arrive in a short time5000ppm;
CPT2610-AT-SO2AE-R10000ppmSulfur dioxide transmitter
Standard range: 0-2000ppm;Can arrive in a short time10000ppm;
CPT2620AT-E25Oxygen concentration transmitter
Conditions of Use
Gas background: CO2,O2,N2,SO2;
pressure:atmospheric pressure±10%;
temperature:- 30~50°C;
humidity: 15-90%RH,There should be no condensation;
Technical Parameter:
Zui High Resolution: 1.5ppm;
Linearity: <±1%;
response timeT90: <25s (@400ppm)
drift: < 2% /monthly;
recovery time: < threeMinutes(cause2000ppmBelow to0
4-30Minutes(cause2000ppmUp to0
CPT2620AT-E25
Electrochemical gas transmitter
name |
name |
range |
repeat accuracy |
specifications |
Conditions of Use |
other |
|
oxygen |
O2 |
0-30% |
±2% |
2620-A2 |
-20℃-55℃ |
environment, CO2crossing<0.1% |
|
oxygen |
O2 |
0-30% |
±2% |
2620-OX2 |
-20℃-50℃ |
Used for engine exhaust gas,The flue gas must first be cooled to room temperature. |
|
oxygen |
O2 |
0-100% |
±2% |
2620A-E25 |
5℃-40℃; 10-90%RH,No condensation; atmospheric pressure±20%; accuracy: <±1%FS; T90: 14s |
environment.be subjected toO3Impact and destruction;>tensppmAmmonia has interference |
|
oxygen |
O2 |
0-100% |
±2% |
2620AT-E25 |
5℃-40℃; 10-90%RH,No condensation; atmospheric pressure±20%; accuracy: <±1%FS; T90: 14s |
low pressure vesselPay attention to exceeding the standard pressure and being less than2kg/cm2Special orders can be placed,But it is possible that the lifespan may be shortened. Used in the flue gas of commercial fuel burners,The flue gas must first be cooled to room temperature., lifespan~1Year. |
|
oxygen |
O2 |
0-100% |
±2% |
2620A-E50 |
5℃-40℃; 10-90%RH,No condensation; atmospheric pressure±20%; accuracy: <±2%FS; T90: 60s |
environment.be subjected toO3Impact and destruction;>tensppmAmmonia has interference |
|
oxygen |
O2 |
0-100% |
6 |
2620AT-E50 |
5℃-40℃; 10-90%RH,No condensation; atmospheric pressure±20%; accuracy: <±2%; T90: 60s |
low pressure vesselPay attention to exceeding the standard pressure and being less than2kg/cm2Special orders can be placed,But it is possible that the lifespan may be shortened. Used in the flue gas of commercial fuel burners,,The flue gas must first be cooled to room temperature., lifespan1+Year. |
|
oxygen |
O2 |
0-100%Vol |
±15% |
2510D0 |
-10℃-45℃ 5-30psig(0.34-2.04atm) |
Constant temperature and pressure |
|
oxygen |
O2 |
0-100%Vol |
±3% |
2510TH-T |
-10℃-300℃ 5-30psig(0.34-2.04atm) |
constant voltage |
|
oxygen |
O2 |
0-1,2,5,10,25,100%Vol |
±3% |
2510QHP-TP |
-10℃-300℃ 5-30psig(0.34-2.04atm) |
industry |
Beijing Beidouxing Industrial Chemistry Research Institute
Beijing Beidouxing Technology Co., Ltd
: