NSureIntroduction:
NSureOnline sulfur and nitrogen analyzers can be effectively used for continuous monitoring and analysis of sulfur content in refineries, natural gas pipelines, and purification plants, meeting product specifications from the most economical and practical perspective. They have won years of reputation for their stable and reliable performance, simple operation, and no need for too much manual involvement. It is an ideal choice for measuring the sulfur and nitrogen content of natural gas, liquefied petroleum gas, and oil products.
Measurement principle:
Total sulfur analysis:NSure Sulfur
Analyze compliance with standardsASTM D5453, D6667, ISO 20846,SH/T0689,GB/T 11060.8
UV Fluorescence Spectroscopy(UVF)Sulfur measurement technology is a fast and accurate method for quantitative analysis of sulfur, which can be used in1-2Complete within minutes as low as20ppbRapid determination of sulfur content up to a hundred levels.
R-S + O2 1000°C SO2 + combustion products
SO2 + hv→SO2*→SO2 + hν’
A certain amount of sample burns at high temperature, and all sulfur elements are converted into molecular statesSO2After being exposed to ultraviolet light, it emits fluorescence. The generated fluorescence is converted into an electrical signal proportional to the sulfur content in the sample by a photomultiplier tube and detected. Compared to the lead acetate paper tape method for measuring sulfur, the ultraviolet fluorescence method is more stable and does not require consumables, nor does it produce lead waste. This method is not availableXThe issue of matrix interference in radiation can provide accurate analysis results with lower sulfur content without the need for column switching or blowback. Because the detector used eliminates the quenching effects of carbon dioxide and water, you will be able to obtain more stable and excellent linear range analysis results.
Total nitrogen analysis:NSure Nitrogen
Analyze compliance with standardsASTM D4629, DIN 38409, TEIL 27, ASTM D5176, EN 12225
Applying accurate and precise chemical fluorescence detection(CLND)Technology,,Analytical instruments can be used1-2Complete within minutes from20ppbRapid determination of nitrogen content at the hundred level. Chemiluminescence is a rapid nitrogen measurement method that can be used for almost any liquid and gas sample.
R-N + O2 1000°C NO + combustion products
NO + O3→NO2* + O2→NO2 + O2 + hν’
A certain amount of sample burns at high temperature, and all nitrogen elements are converted intoNOMolecules. thenNOMolecules fully mix with ozone to occur React and emit light. The emitted light is converted into an electrical signal proportional to the nitrogen content present in the sample through a photomultiplier tube and detected.
NSureCharacteristics:
high-precision
Excellent repeatability and precision provide users with high-quality detection data. Good repeatability means that users can fully trust the data it provides. Users can confidently use their data to adjust process conditions to ensure that the total sulfur content in the products produced by desulfurization and blending processes meets the standard. The repeatability of an instrument is measured by its standard deviation.NSureLong term measurements of diesel, gasoline, and natural gas have yielded excellent repeatability results. In most applications, its repeatability over the full range is superior1%The accuracy is better than1%.
rapid analysis
NSureThe analyzer technology is advanced. From sample injection, to complete combustion of the sample, to analysis of the results, the entire process1It can be completed in minutes. Greatly saving time costs. And the analysis and detection process is simple and efficient - no sample residue will be generated
Data interaction interface
Through the touch screen, method settings, calibration, verification, alarm settings, and troubleshooting operations can be directly performed; Equipped with local historical data storage, advanced data output, and interactive functions; Data output control.
Diverse communication methods
4–20 mAIndependent output, digital input and output for remote control and status display
Network Communication ProtocolRTU (Standard configuration):RS-485
Network Communication ProtocolTCP/IPAnd Ethernet(Standard configuration)
Remote Workstation(Optional)
Alarm and Diagnosis
Intelligent design, instruments can perform self diagnosis, facilitating fault handling and repair
NSureTechnical parameters:
Analysis method |
NSure Sulfur:UV fluorescence method(UVF) NSure Nitrogen:chemiluminescent detection(CLND) |
Analysis standards |
NSure Sulfur: ASTM D5453, D6667, ISO 20846;SH/T0689, GB/T 11060.8 NSure Nitrogen: ASTM D4629, DIN 38409, TEIL 27, ASTM D5176, EN 12225 |
certificate/Regional classification |
CSA/UL, NEC Class 1 Division 2 Groups A, B, C & D ATEX: Zone 1 Ex dbibpxb IIC T4 Gb (T3 with heated valve) Zone 2 Ex dbnApxb IIC T4 Gb (T3 with heated valve) |
Detection range |
Sulfur content analysis: •0-1 ppm/wtand0–5% (On site adjustable) Analysis of nitrogen content: •0-1 ppm/wtand0–2000 ppm/wt (On site adjustable) Attention: If you need a larger range, please consult the manufacturer. |
Flow path |
Single channel or dual channel options are available |
Detection lower limit(LLD) |
20PPb |
Company |
ppm(mg / m3Optional, users need to provide relevant parameters) |
Repeatability |
less than1% |
response time |
Each flow path1minute |
Analysis time |
Each flow path can reach1minute |
accuracy |
<1% |
noise |
<1% |
Zero line drift (weekly) |
<1% |
calibration/verification |
Use user-defined parameters for automatic or manual system validation and calibration |
calibration/Verification time |
Single flow path1minute |
Communication output |
4–20 mAIndependent output Digital inputs and outputs for remote control and status display Network Communication ProtocolRTU (Standard configuration):RS-485 Network Communication ProtocolTCP/IPAnd Ethernet(Standard configuration) Remote Workstation(Optional) |
Self diagnostic function |
have |
Gas requirements |
carrier gas:Argon gas, instrument air*Or nitrogen gas(99.975%), 50 psig, 5–15 cc/min Auxiliary combustion gas: Instrument air*Or oxygenO2(99.975%), 50 psig ,350-500 cc / min Pneumatic component air supply: instrument air, 80-100 psig(5.6-6.8 Bar) Instrument blowing air supply: Instrument air, pressure of80-120 psig(5.6-7 Bar); The starting traffic is425 LPM(15 SCFM)The continuous operation flow is130 LPM(4.6 SCFM) note appended1Some versions only require instrument air for operation note appended2Instrument air requires cleanliness, dryness, and no particles |
Injection requirements |
Sample phase: gas or liquid Sample inlet pressure: ≤400 psig(depending on the application) Sample inlet temperature: ≤100? C Sample conditions: ≤0.5um Sample return pressure: less than the injection pressure10-20psi; keep≥25psiThe pressure returns to the process pipeline |
Voltage/electric current/frequency |
115 VAC (13 Amps) or 230 VAC (6.5 Amps); 50-60 Hz |
power |
1500 W |
display |
LCD(Having7Inch touch screen or15Two types of inch touch screens are available, with touch screens used for programming devices, displaying current and historical analysis results, and alarm status |
Temperature requirements |
0-40? CUnder extreme conditions, it may be necessary to usevortecCooler (optional) |
size |
W x D x H :66 x 43.2 x 114.3cm |
weight |
181.4 Kg |
Packaging box size and weight |
86” x 42” x 56” 775 lbs. |