Detailed information on YD-300APE thin film density tester and specific gravity meter:
PE film density tester, specific gravity meterOverview of YD-300A:
It is based on the principle of Archimedes' water displacement method according to ASTM D297-93, D792-00, D618, D891. This machine is mainly used in industries such as rubber, plastic, wire and cable, food, composite materials, cosmetics, shoe materials, glass, precious metal hardware recycling, etc. It can directly read the average weight of solid, granular, thin film, floating, and powder samples in air, water, as well as the apparent density value, density value, wear amount, and wear index.
Main features:
1. The water container is molded into one piece, which is not easy to cause water leakage and has a normal service life of more than 8 years.
2. Fully automatic zero point tracking function, with full weight shedding throughout the entire process
3. It has a solution compensation function and can set different medium liquid densities according to different sample testing requirements
(For example, when testing the density of magnetic material embryos, silicone oil can be used as a medium to set the silicone oil density)
4. It has temperature compensation function, which can set the actual temperature of the medium liquid and directly read the density value under the current temperature condition.
5. Equipped with professional windproof covers to ensure the stability of the measurement environment.
6. Adopting a large sink design, the testing operation is convenient and simple. And it also reduces the error caused by the buoyancy of the suspension line.
PE film density tester, specific gravity meterYD-300A Technical Parameters:
1. Model: YD-300A
2. Weighing range: 0.005g~300g
3. Specific gravity measurement accuracy: 0.001 (i.e. density resolution can reach up to the thousandth percentile)
4. Specific gravity measurement range: Specific gravity values greater than 1 or less than 1 can be tested
5. Measurable plastics: solid plastics, granular plastics, plastic pellets, plastic films
6. Testing time: 2-3 steps, approximately 5 seconds to read
Measurement steps:
▼ [Measuring materials with a density less than one] (anti floating frame is standard for measuring floats)
1. Place the anti floating bracket in the water and press the zero button to remove the weight
2. Place the product on the measuring table to measure the weight in the air, record W1, and then put the product into water to measure the weight in water, W2, and directly read the density and volume
Precautions for using an electronic density meter:
1. Do not directly place the measuring object containing static electricity on the densitometer for measurement, as it may affect the measurement results.
2. During testing, it is necessary to avoid accidentally dropping water droplets on the measuring table, otherwise it will affect the accuracy of the measured values.
3. When operating, be careful and place the measuring object in the center of the measuring table.
4. During the measurement process, the object placed on the water suspension bar must be completely submerged in water and ensure that there are no bubbles on the surface of the measured sample.
5. Before each measurement, press the reset button to reset to zero to avoid measurement errors.
Supplier: Shenzhen Yongda Instrument Equipment Co., Ltd
ShenZhen YongDa Instrument Equipment Co.,LTD