PTC-30A Solid Liquid Integrated Blow and Capture Instrument
Brief description: The PTC-30A chromatograph pretreatment device solid-liquid integrated blowdown and capture instrument is a 76 position solid-liquid
Product details

summary

PTC-30A typeChromatographic pre-treatment deviceSolid liquid integrated blowing and capturing instrumentIt is a 76 bit device with an electronic cold trapSolid liquid integrated blowing and capturing instrumentSupports automatic and precise sampling of liquid samples into blowing bottles for blowing and capturing, as well as automatic addition of distilled water for shaking and mixing of solid samples for direct blowing and capturing.

637684352097836154315.jpg

Performance indicators:

PTC-30A typeChromatographic pre-treatment deviceSolid liquid integrated blowing and capturing instrument

1. Sample grade: 76th grade, 40ml VOA sample bottle

2. Purging tube temperature: room temperature~100 ℃, step size 1 ℃

3. Temperature control range of cold trap (electronic semiconductor refrigeration): -40 ℃ to room temperature, step size 1 ℃, no need for liquid nitrogen refrigeration

4. Desorption temperature of capture tube: 150-380 ℃, heating rate>3000 ℃/min; Reduce from 250 ℃ to 35 ℃ within 90 seconds

5. Heating temperature of pipeline: room temperature~220 ℃, step size 1 ℃

6. Heating temperature of water purifier: room temperature~400 ℃

7. Cleaning distilled water temperature: room temperature~90 ℃, step size 1 ℃

8. Solid sample bottle heating: room temperature~100 ℃, step size 1 ℃

9. Solid sample mixing: 5ml distilled water, shake and mix

10. Glass blowing tube: 5ml blowing tube

11. Catching pipe size: stainless steel material Φ 3mm × 180mm × 0.1mm

12. Purging flow rate: 10-150ml/min

13. Timing range: 1 second to 100 minutes

14. Timing error: better than 0.1%

15. Air circuit pressure resistance:> 0.4MPa

16. Synchronous signal output: 2 switch signals, with a linkage switch time of 1-2 seconds

17. Power supply: AC220V 50Hz

18. Power:< 800W

19. Instrument size: 640mm * 750mm * 510mm

20. Instrument weight: approximately 42Kg


Environmental adaptability

1) Backblowing carrier gas pressure: ≤ 0.4MPa

2) Environmental temperature: 5-35 ℃

3) Relative humidity: ≤ 85%


Main functions and features

1. Strong universal performance: can be used in combination with any brand of gas chromatograph (GC) and (GC-MS)

2. Easy to operate and highly automated: simply place the sample bottle in the sample tray, and other operating software will complete it, so the experiment has good repeatability; The host is equipped with a large size

Touch LCD screen, rich interface information, fully tracking temperature and operation commands throughout the process

3. The cold trap adopts semiconductor cooling and air cooling, with a low cooling temperature of up to -40 ℃ (at room temperature of 20 ℃)

4. The heating of the capture tube is achieved through direct resistance heating, with a heating rate greater than 3000 ℃/min

5. The built-in foam sensor can detect the foam in the purging pipe, prevent the way of polluting the sample, and protect the entire analysis system

6. Users can customize the cleaning frequency of the sampling needle and blowing tube

7. Solid sample bottles can be heated and directly injected with distilled water for oscillation, mixing, and blowing

8. The gas separation between the capture tube and the blowback tube reduces cross contamination between samples. In the blowback cycle, compounds blown out of the capture trap will not flow into the blowback

Guanzhong

9. The water trap removes water vapor at the blowing end, greatly reducing the impact of water vapor on GC and GC/MS

10. The sample tubing is made of PEEK material and treated with silane inert stainless steel to reduce residual pollution

11. All pipelines and six way valves are temperature controlled for heating, eliminating system cold spots and reducing sample loss

12. Provide a synchronization interface that can start both the chromatography and workstation simultaneously during sample injection


Common application areas

By combining with GC or GC/MS, it can be widely applied in environmental analysis, such as the analysis of organic pollutants in drinking water, wastewater, and soil, as well as the analysis of volatile compounds (such as odor components) in food.

fully automaticSolid liquid integrated blowing and capturing instrument

List of applicable main standards

GBT5750.8-2006 Standard Test Method for Drinking Water, Determination of Organic Matter Index

HJ605-2011 Determination of volatile organic compounds in soil and sediment by blow sweep capture/gas chromatography-mass spectrometry method

HJ639-2012 Determination of volatile organic compounds in water quality by blow sweep capture/gas chromatography-mass spectrometry method

HJ686-2014 Determination of volatile organic compounds in water quality by blow sweep capture/gas chromatography-mass spectrometry method

HJ735-2015 Determination of volatile halogenated hydrocarbons in soil and sediment by blow sweep capture/gas chromatography-mass spectrometry method

HJ788-2016 Determination of Acetonitrile in Water Quality by Sweep Capture/Gas Chromatography Method.