Fluoropore surface filter membrane
Fluoropore membrane supported by high-density polyethylenePTFE film composition (FHUP does not have this support).Fluoropore membranes have a wide range of chemical compatibility.
Mitex surface filter membrane
Mitex is a hydrophobic material without supportPTFE membrane. Can be used for extreme conditions that other membranes cannot withstandUsed under chemical or temperature conditions (maximum)260 ° C).
LCR surface filter membrane
LCR is a hydrophilic PTFE without supportMembrane, compatible with all commonly used HPLC solvents.The aqueous solution can be filtered without pre soaking. In the needleUsed in head filters.
Omnipore surface filter membrane
Omnipore membrane is a hydrophilic PTFE membrane,Compatible with almost all solvents and acid-base solutionsPlease use LCR membrane for HPLC solvent filtration.
Technical indicators
Sterilization method: High temperature and high pressure sterilization (121 ° C,
1 bar) or EO
Bacterial endotoxin: 0.5 EU/mL
Weight of dissolved substances:< 0.5%
application | Filter membrane code 1 |
aperture (μm) |
Bubble Point (bar)2 |
Thickness (μ m) | Flow rate of water (mL/min/cm2) 3 | Air flow rate (L/min/cm2) 4 | Operating temperature (° C) | Porosity rate (%) |
Fluoropore membrane (hydrophobic) | ||||||||
Clarify and filter acids, bases, and solvents, air monitoring, filtration or gas exchange, UV spectroscopy | FGLP | 0.22 | 1 | 150 | 24 | 5 | 130 | 85 |
FHLP | 0.45 | 0.63 | 150 | 60 | 8 | 130 | 85 | |
FALP | 1 | 0.5 | 150 | 110 | 16 | 130 | 85 | |
FSLW | 3 | 1 | 150 | 286 | 20 | 130 | 85 | |
FHUP | 0.45 | 0.63 | 50 | 75 | 9 | 260 | NA | |
Mitex filter membrane (hydrophobic) | ||||||||
Clarify and filter acid, alkali, and low-temperature liquids, clarify and filter fuel, analyze water samples, and isolate RNA | LSW | 5 | 0.05 | 140 | 70 | 6 | 260 | 65 |
LCW | 10 | 0.03 | 130 | 220 | 2 | 260 | 65 | |
LCR filter membrane (hydrophilic) | ||||||||
Clarify and filter acid, alkali, low-temperature liquids, and diluted protein solutions, clarify and filter fuel, analyze water samples, and isolate RNA | FHLC | 0.45 | NA | 140 | 70 | 8 | 130 | 80 |
Omnipore membrane (hydrophilic) | ||||||||
Clarify and filter acid, alkali solutions, and almost all solvents | JVWP | 0.1 | 23.6 | 30 | 100 | |||
JGWP | 0.2 | 13.6 | 65 | 50 | ||||
JHWP | 0.45 | 7.9 | 65 | 15 | ||||
JAWP | 1 | 3.6 | 85 | 5 | ||||
JMWP | 5 | 2.1 | 85 | 1.5 | ||||
JCWP | 10 | 0.7 | 85 | 0.5 | ||||
1 corresponds to the first 4 digits of the directory number | ||||||||
2. Determine the boiling point using methanol | ||||||||
3 Fluoropore determined with methanol; Mitex and LCR water use |
||||||||
The air flow rate of Mitex 4 refers to the time (in seconds) required for 100 cm3 of air to pass through a membrane with an area of 1 in 2 (Gurley test) |
ordering information | ||||||||||
Aperture, μm |
Filter membrane diameter,mm |
quantity/packing |
Catalog Number |
|||||||
Fluoropore (PTFE)Surface filter membrane | ||||||||||
0.22 |
13 |
100 |
FGLP 013 00 |
|||||||
25 |
100 |
FGLP 025 00 |
||||||||
47 |
100 |
FGLP 047 00 |
||||||||
90 |
50 |
FGLP 090 50 |
||||||||
142 |
50 |
FGLP 142 50 |
||||||||
293 |
25 |
FGLP 293 25 |
||||||||
0.5 |
13 |
100 |
FHLP 013 00 |
|||||||
25 |
100 |
FHLP 025 00 |
||||||||
47 |
100 |
FHLP 047 00 |
||||||||
90 |
50 |
FHLP 090 50 |
||||||||
142 |
50 |
FHLP 142 50 |
||||||||
293 |
25 |
FHLP 293 25 |
||||||||
1 |
13 |
100 |
FALP 013 00 |
|||||||
25 |
100 |
FALP 025 00 |
||||||||
47 |
100 |
FALP 047 00 |
||||||||
90 |
50 |
FALP 090 50 |
||||||||
142 |
50 |
FALP 142 50 |
||||||||
293 |
25 |
FALP 293 25 |
||||||||
3 |
25 |
100 |
FSLW 025 00 |
|||||||
47 |
100 |
FSLW 047 00 |
||||||||
90 |
25 |
FSLW 090 25 |
||||||||
142 |
10 |
FSLW 142 00 |
||||||||
293 |
5 |
FSLW 293 00 |
||||||||
Without paddingFluoropore (PTFE)Surface filter membrane | ||||||||||
0.45 |
47 |
100 |
FHUP 047 00 |
|||||||
Mitex (PTFE)Surface filter membrane, smooth surface | ||||||||||
5 |
13 |
100 |
LSWP 013 00 |
|||||||
25 |
100 |
LSWP 025 00 |
||||||||
37 |
100 |
LSWP 037 00 |
||||||||
47 |
100 |
LSWP 047 00 |
||||||||
90 |
25 |
LSWP 090 25 |
||||||||
142 |
50 |
LSWP 142 50 |
||||||||
293 |
25 |
LSWP 293 25 |
||||||||
10 |
13 |
100 |
LCWP 013 00 |
|||||||
25 |
100 |
LCWP 025 00 |
||||||||
47 |
100 |
LCWP 047 00 |
||||||||
90 |
25 |
LCWP 090 25 |
||||||||
142 |
50 |
LCWP 142 50 |
||||||||
293 |
25 |
LCWP 293 25 |
||||||||
Mitex (PTFE)Surface filter membrane, grid | ||||||
5 |
25 |
100 |
LSWG 025 00 |
|||
47 |
100 |
LSWG 047 00 |
||||
10 |
25 |
100 |
LCWG 025 00 |
|||
47 |
100 |
LCWG 047 00 |
||||
LCR(Hydrophilicity)PTFE)Surface filter membrane | ||||||
0.45 13 |
100 |
FHLC 013 00 |
||||
25 |
100 |
FHLC 025 00 |
||||
47 |
100 |
FHLC 047 00 |
||||
Omnipore(Hydrophilicity)PTFE)Surface filter membrane | ||||||
0.1 |
13 |
100 |
JVWP 013 00 |
|||
25 |
100 |
JVWP 025 00 |
||||
47 100 |
JVWP 047 00 |
|||||
90 25 |
JVWP 090 25 |
|||||
142 25 |
JVWP 142 25 |
|||||
0.2 |
13 |
100 |
JGWP 013 00 |
|||
25 |
100 |
JGWP 025 00 |
||||
47 |
100 |
JGWP 047 00 |
||||
90 |
25 |
JGWP 090 25 |
||||
142 |
25 |
JGWP 142 25 |
||||
0.45 |
13 |
100 |
JHWP 013 00 |
|||
25 |
100 |
JHWP 025 00 |
||||
47 |
100 |
JHWP 047 00 |
||||
90 |
25 |
JHWP 090 25 |
||||
142 |
25 |
JHWP 142 25 |
||||
1 |
13 |
100 |
JAWP 013 00 |
|||
25 |
100 |
JAWP 025 00 |
||||
47 |
100 |
JAWP 047 00 |
||||
90 |
25 |
JAWP 090 25 |
||||
142 |
25 |
JAWP 142 25 |
||||
5 |
13 |
100 |
JMWP 013 00 |
|||
25 |
100 |
JMWP 025 00 |
||||
47 |
100 |
JMWP 047 00 |
||||
90 |
25 |
JMWP 090 25 |
||||
142 |
25 |
JMWP 142 25 |
||||
10 |
13 |
100 |
JCWP 013 00 |
|||
25 |
100 |
JCWP 025 00 |
||||
47 |
100 |
JCWP 047 00 |
||||
90 |
25 |
JCWP 090 25 |
||||
142 |
25 |
JCWP 142 25 |