Zibo Tovi Vacuum Equipment Co., Ltd
Home>Products>PW centrifugal sewage pump
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    16653319839
  • Address
    Baita Industrial Park, Boshan District, Zibo City
Contact Now
PW centrifugal sewage pump
PW centrifugal sewage pump
Product details



Product features of PW centrifugal sewage pump:

Installation of PW centrifugal sewage pump:

1) Remove the grease and dirt from the base, and place the base on the foundation.

2) Use a spirit level to check the levelness of the base, and allow for leveling with a wedge iron.

3) Pour cement into the base and anchor bolt holes.

4) After the cement dries up, check whether the base and anchor bolts are loose, tighten the nuts if they are suitable, and recheck the level.

5) Clean the support plane of the base and the foot plane of the water pump and motor, and then install the pump and motor onto the base.

6) Check if the level is consistent with the center of the motor. If not, adjust it with thin iron plates to make it concentric (no more than 3 thin iron plates), and leave a 2-3mm gap between the couplings.

Assembly and disassembly of PW centrifugal sewage pump:

First check for any defects that may affect the assembly of each component, then clean them thoroughly before proceeding with the assembly.

1. Prepare paper pads, plugs, and pipe plugs and install them onto the corresponding components.

2. Install the sealing ring, shaft seal box, oil gauge and oil hole cover, and felt stock into the pump cover, bearing body, bearing box, and bearing cover respectively. 3. First, install the bearings into both ends of the shaft, then install them together into the bearing box, and finally install the bearing cover.

4. Install the bearing body, bearing (4PW without) oil seal ring and washer, impeller, washer and impeller nut in sequence and tighten them, then install the pump body and pump cover. Disassembly and assembly must be done in reverse order.

Precautions for PW centrifugal sewage pump:

1) The inlet and outlet water pipes of the pump should be supported, and the pump body should not be used as a support:

2) The outlet water pipeline should be equipped with gate valves;

A general trash rack should be installed at the inlet of the pump suction pipeline to prevent larger stones and other objects from being sucked into the pump and damaging the blades.

PW centrifugal sewage pump starts, stops, and runs:

A、 start

1) Check if the bearing box has been filled with oil and if the oil level is within the normal range.

2) Check if the rotation direction of the motor is consistent with the rotation direction of the pump.

3) Close the discharge gate valve and pressure gauge plug, and at the same time, pour water into the suction pipe of the pump through the screw hole on the upper part of the pump body.

4) Start the motor and open the pressure gauge plug.

5) When the water pump reaches normal speed and the pressure gauge displays the corresponding pressure, open the vacuum gauge plug and gradually open the gate valve on the drainage pipeline until needed.

B、 stop

1) First, slowly close the gate valve of the water outlet pipeline, and then cut off the power supply.

2) In case of freezing season, after stopping the machine, open the square screw plug at the bottom of the pump body and drain the stored water to prevent freezing and cracking.

3) If not used for a long time, each component should be disassembled and cleaned, and rust proof oil should be applied to the sliding surface for proper storage.

C、 operate

1) During the operation of the pump, it is necessary to pay attention to the heating condition of the instruments and bearings, the leakage of the packing, and whether the vibration and noise of the pump are normal. If any abnormalities are found, they should be dealt with in a timely manner.

2) The maximum temperature of the bearing shall not exceed 75 ℃.

3) The bearing oil should be maintained at the normal oil level line, and should not be too high or too low. If it is too low, it should be refilled in a timely manner.

4) When the clearance between the sealing ring and the impeller exceeds the following specified value, a new sealing ring should be replaced.

When the diameter of the suction port is ≤ 100mm and the total clearance in the diameter direction is ≥ 1.5mm

When the diameter of the suction port is greater than 100mm and the total distance in the diameter direction is ≥ 2mm

Product parameters of PW centrifugal sewage pump:

Model number

Caliber
mm

Traffic volume
m3/h

Head lift
m

Power
kw

Rotational speed
r/min

Efficiency
%

25PW8-22-1.1

25

8

22

1.1

2825

38.5

32PW12-15-1.1

32

12

15

1.1

2825

40

40PW15-15-1.5

40

15

15

1.5

2840

45.1

40PW15-30-2.2

40

15

30

2.2

2840

48

50PW20-7-0.75

50

20

7

0.75

1390

54

50PW10-10-0.75

50

10

10

0.75

1390

56

50PW20-15-1.5

50

20

15

1.5

2840

55

50PW15-25-2.2

50

15

25

2.2

2840

56

50PW18-30-3

50

18

30

3

2880

58

50PW25-32-5.5

50

25

32

5.5

2900

53

50PW20-40-7.5

50

20

40

7.5

2900

55

65PW25-15-2.2

65

25

15

2.2

2840

52

65PW37-13-3

65

37

13

3

2880

55

65PW25-30-4

65

25

30

4

2890

58

65PW30-40-7.5

65

30

40

7.5

2900

56

65PW35-50-11

65

35

50

11

2930

60

65PW35-60-15

65

35

60

15

2930

63

80PW40-7-2.2

80

40

7

2.2

1420

52

80PW43-13-3

80

43

13

3

2880

50

80PW40-15-4

80

40

15

4

2890

57

80PW65-25-7.5

80

65

25

7.5

2900

56

100PW80-10-4

100

80

10

4

1440

62

100PW110-10-5.5

100

110

10

5.5

1440

66

100PW100-15-7.5

100

100

15

7.5

1440

67

100PW85-20-7.5

100

85

20

7.5

1440

68

100PW100-25-11

100

100

25

11

1460

65

100PW00-30-15

100

100

30

15

1460

66

100PW100-35-18.5

100

100

35

18.5

1470

65

125PW30-15-11

125

130

15

11

1460

62

120PW130-20-15

125

130

20

15

1460

63

150PW145-9-7.5

150

145

9

7.5

1440

63

150PW180-15-15

150

180

15

15

1460

65

150PW180-20-18.5

150

180

20

18.5

1470

75

150PW180-25-22

150

180

25

22

1470

76

150PW130-30-22

150

130

30

22

1470

75

150PW180-30-30

150

180

30

30

1470

73

150PW200-30-37

150

200

30

37

1480

70

200PW300-7-11

200

300

7

11

970

73

200PW250-11-15

200

250

11

15

970

74

200PW400-10-22

200

400

10

22

1470

76

200PW400-13-30

200

400

13

30

1470

73

200PW250-15-18.5

200

250

15

18.5

1470

72

200PW300-15-22

200

300

15

22

1470

73

200PW250-22-30

200

250

22

30

1470

71

200PW350-25-37

200

350

25

37

1980

75

200PW400-30-55

200

400

30

55

1480

70

250PW600-9-30

250

600

9

30

980

74

250PW600-12-37

250

600

12

37

1480

78

250PW600-15-45

250

600

15

45

1480

75

250PW600-20-55

250

600

20

55

1480

73

250PW600-25-75

250

600

25

75

1480

73

300PW800-12-45

300

800

12

45

980

76

300PW500-15-45

300

500

15

45

980

70

300PW800-15-55

300

800

15

55

980

73

300PW600-20-55

300

600

20

55

980

75

300PW800-20-75

300

800

20

75

980

78

300PW950-20-90

300

950

20

90

980

80

300PW1000-25-110

300

1000

25

110

980

82

350PW1100-10-55

350

1100

10

55

980

84.5

350PW1500-15-90

350

1500

15

90

980

82.5

350PW1200-18-90

350

1200

18

90

980

83.1

350PW1100-28-132

350

1100

28

132

740

83.2

350PW1000-36-160

350

1000

36

160

740

78.5

400PW1500-10-75

400

1500

10

75

980

82.1

400PW2000-15-132

400

2000

15

132

740

85.5

400PW1700-22-160

400

1700

22

160

740

82.1

400PW1500-26-160

400

1500

26

160

740

83.5

400PW1700-30-200

400

1700

30

200

740

83.5

400PW1800-32-250

400

1800

32

250

740

82.1

500PW2500-10-110

500

2500

10

110

740

82

500PW2600-15-160

500

2600

15

160

740

83

500PW2400-22-220

500

2400

22

220

740

84

500PW2600-24-250

500

2600

24

250

740

82


PW centrifugal sewage pump products hot selling cities: Jiangsu, Shandong, Henan, Zhejiang, Hebei
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!