Product Overview
The Picarro G2106 gas concentration analyzer can accurately measure ethylene (C2H4) and water vapor (H2O) in real-time, with a sensitivity of parts per billion (ppb), and the drift generated for agricultural and soil science applications can be ignored. This analyzer requires almost no consumables, therefore it has significant advantages of ease of use and lower purchase cost. This analyzer has a sturdy structure and is easy to transport. This analyzer can be set up and put into operation within a few minutes, and usually does not require any sample preparation or drying treatment.
Product Features
• Fast, continuous, real-time measurement of C2H4
• Long term stability to meet low-frequency calibration requirements
• Small footprint, suitable for on-site or laboratory deployment, no need for consumables
• Equipped with water correction function, automatically reporting dry gas mole fraction
Main technical parameters
Picarro G2106Performance specifications |
|
|
|
|
Target gas (requires air like background) |
Detection lower limit*(5 second/ 5minute,1σ) * Ensure that the following operating conditions are met |
Maximum drift*(24 Within hours/Within a month) (50 The difference between the maximum values of the minute averages * Ensure that the following operating conditions are met |
|
|
C2H4 |
2 ppb / 0.2 ppb |
< ±4 / ±10 ppb |
|
|
|
Picarro G2106System specifications |
|
||
|
|
|
||
|
measuring technique |
Cavity oscillation spectroscopy( CRDS )technology |
||
|
Measurement pool temperature control |
±0.005 ℃ |
||
|
Measurement pool pressure control |
±0.0002Atmospheric pressure |
||
|
|
|
||
|
measuring range |
0–300 ppm |
||
|
Measurement interval |
about 5 second |
||
|
Sample temperature |
-10 to45 ℃ |
||
|
Sample flow rate |
stay 760 Underneath less than 0.4 Standard liters per minute( SLM )No need for filtering |
||
|
Sample pressure |
300 to 1000 Tuo(40 to 133 Kilopascals) |
||
|
Sample humidity |
relative humidity( RH )less than99%, in40 ℃Under non condensing conditions, there is no need for drying |
||
|
ambient temperature |
10 to35 ℃(During runtime), -10 to50 ℃(During storage) |
||
|
ambient humidity |
Relative humidity under non condensing conditions( RH )less than99% |
||
|
Other gases measured |
H2O |
||
|
enclosure |
Pump (external, included), keyboard (included), mouse (included)LCDMonitor (optional) |
||
|
data output |
RS-232EthernetUSBAnalog signal (optional)0–10Fu |
||
|
Air inlet connector |
¼inchSwagelok ® PFAConnector |
||
|
External dimensions |
Including the legs, it is 17 Inches widex 7Inch heightx 17.5Inch length(43.2 x 17.9 x 44.5Cm), the small external pump module is 5.6 Inches widex 6.4Inch heightx 11.9Inch length(14.3 x 16.3 x 30.3Centimeters) |
||
|
Installation form |
Workbench or 19 Inch rack mounted chassis |
||
|
weight |
Analyzer 46 Pound( 20.9 Kg), pump 14.4 Pound(6.5 Kilogram (excluding connectors) |
||
|
Power requirements |
100–240Alternating current,47–63 Hz(Automatic detection), the total power at startup is less than 260 When the tile is in steady state, it is 110 Watt (analyzer),80 Watt (pump) |
||
|
Application precautions |
We need an air like background. WhenH2O、CO2 andCH4 The concentration of [substance] is much higher than the normal environmental level, and interference may occur when measuring organic compounds including but not limited to ethane, acetylene, ammonia, and other nitrogen and sulfur compounds. Users should use prepared laboratory samples for validation. For more details about the experimental conditions, please contact us. When the system is used in recycling applications, the pressure difference in the instrument air path may draw in external air. |