Picarro-G2401-m aviation specific gas concentration analyzer
Picarro-G2401-m aviation specific gas concentration analyzer
Product details

product overview

The Picarro G2401-m gas concentration analyzer can simultaneously measure carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), and water vapor (H2O), with a sensitivity of parts per billion (ppb). Drift caused by atmospheric science, air quality, and quantitative emission applications can be ignored. Flight optimization design components minimize the impact of aircraft vibration, pitch, roll, and rapidly changing environmental conditions. Therefore, this analyzer can be operated on aircraft to achieve urban surveying or vertical profile analysis.

Product Features

Simultaneous and continuous measurement of four atmospheric trace gases

Billion parts per billion (ppb) sensitivity, accuracy, and precision, with extremely low drift

Robust design ensures performance during flight

Equipped with water correction function, automatically reporting dry gas mole fraction

Main technical parameters

PicarroG2401-mAnalyzer specifications

CO2 specifications

CH4 specifications

COspecifications

H2Ospecifications

Original accuracy(1-σ300 Within seconds,20 HzVibration

Moving,1 g)Ensure accuracy within the following range and operating conditions

≤ 200 ppb

≤ 2 ppb

≤ 30 ppb

≤ 150 ppm

Drift at standard temperature and pressure(24 Within hours)

50 The worst value of the minute average: Ensure drift within the following range and operating conditions)

≤ 200 ppb

≤ 1.5 ppb

≤ 15 ppb

≤ 100 ppm + 5%reading

Drift during constant temperature changes(3 Within the hour30 The worst value difference of the second average; The temperature change rate is per hour under the following operating conditions15 ℃

≤ 7.5 ppbv / ℃

≤ 0.05 ppbv / ℃

≤ 1.5 ppb / ℃

Not Applicable

Drift during constant pressure changes

30 The worst value difference of the second average; The pressure change rate is less than per second under the following operating conditions 1.4 To)

≤ 700 ppb

≤ 7.5 ppb

≤ 50 ppb

Not Applicable

scope of work

0–1000 ppm

0–20 ppm

0–5 ppm

0–7 %v H2O /

39 ℃Dew point (no condensation)

Ensure specification range

300–500 ppm

1 ppm–3 ppm

0–1 ppm

0–3 %v H2O

Measurement Interval

≤ 3.5second

≤ 3.5second

≤ 3.5second

25 ℃Dew point (no condensation)

rise time/fall time( 10–90% / 90–10% )

≤ 3second

≤ 3second

≤ 3second

Not Applicable

PicarroG2401-mAnalyzer specifications

measurement

cavity ring-down spectroscopy( CRDS )technology

Measurement pool temperature control

±0.005 ℃

Measurement pool pressure control

±0.0002 atmospheric pressure

sample temperature

-10 ℃to45 ℃

Sample flow rate

exceed250–1000Time less than 0.6 Standard liters per minute( slm )No need for filtering

Sample pressure

250 to 1000 Tuo(40 to 133 Kilopascals)

Sample humidity

relative humidity( RH )less than99%, in40 ℃Under non condensing conditions

ambient temperature

The operating temperature is10 ℃to35 ℃The storage temperature is -10 to50 ℃

Maximum rate of change in ambient temperature

Every hour15 ℃

ambient humidity

relative humidity( RH )less than99%Under non condensing conditions

maximum height

250 The height of the support time

Maximum rate of change in height

per minute 1000 rice

Attachment (attached)

Pump (external), keyboard, mouseLCDMonitor (optional)

output

RS-232EthernetUSBSimulation (optional)0–10bend over

Air inlet connector

¼inchSwagelok ®

External dimensions

Analyzer:17.6 Inch lengthx 7Inch heightx 17Inches wide(44.6 x 17.8 x 43.2Centimeters), excluding 0.5 Inch foot external pump:12.8 Inch lengthx 8.9Inch heightx 6.2Inches wide(32.4 x 22.6 x 15.8Centimeters)

weight

70 Pound(31.75 Kilogram, including pump

Power requirements

100–240Alternating current,47–63 Hz(Automatic detection). At startup (total) less than 260 Wa:110 Watt (analyzer), steady state is120 Watt (pump)

Steady state power loss

< 370tile