Polarization melting point tester XPN-203
Polarization melting point tester XPN-203 1. Purpose: The XPN-203 series polarization melting point tester is the most commonly used professional expe
Product details
Polarized melting point testerXPN-203
1、 Purpose:
The XPN-203 series polarizing melting point analyzer is the most commonly used professional experimental instrument for departments such as geology, mineral resources, metallurgy, petrochemicals, chemical fibers, semiconductor industry, drug inspection, and related polymer majors in higher education institutions. The polarization melting point analyzer can be used by a wide range of users for single polarization observation, orthogonal polarization observation, cone light observation, and microscopic photography to observe the deformation, color change, and three state transformation of objects under heating conditions. The polarization melting point tester adopts microcomputer detection and has automatic P, I, D adjustment, and fuzzy manual adjustment functions. The polarization melting point tester displays temperature values and set temperature values through LED, and the instrument display is accurate, clear, and stable. The temperature control can be programmed, and there is an automatic alarm device for "upper and lower" limits, which can check the set temperature data at any time. It is a new generation melting point temperature measurement and control device. The microscope is equipped with accessories such as gypsum λ, mica λ/4 test pieces, quartz wedges, and moving rulers. The polarizing microscope hot stage has scalability and can be connected to computers and digital cameras to edit, save, and print images. Polarization melting point tester is a new type of product with relatively complete functions.
2、 System Introduction:
The polarization melting point analyzer system is a high-tech product developed by perfectly combining precision optical microscopy technology, advanced photoelectric conversion technology, and cutting-edge computer image processing technology. Real time dynamic images can be easily observed on the display screen, and the required images can be edited, saved, and printed.
3、 Technical parameters:
1. Eyepiece
Category magnification Field of view (mm)
Grid eyepiece 10X φ18
Cross shaped eyepiece 10X φ18
Dividing eyepiece 10X φ18
Polarized microscope hot stageXPN-203E
View large image
Polarized microscope hot stageXPN-203Z
View large image
2. Objective lens
Category magnification Numerical aperture (NA) Working distance (mm) Cover glass thickness (mm)
Objective lens 4X 0.10 7.80 -
10X 0.25 4.70 -
25X 0.40 1.75 0.17
40X 0.65 0.72 0.17
63X 0.85 0.18 0.17

3. Magnification factor: 40X-630X System magnification factor: 40X-2600X.
4. Numerical aperture of spotlight: NA1.2/0.22 shake out achromatic spotlight with adjustable center
5. Polarizing mirror: adjustable vibration direction of 360 °, with locking device, movable optical path
6. Polarizer: can be removed from the optical path, with a rotation range of 90 ° and a built-in Burgundy mirror. The center and focal length can be adjusted
7. Compensator: λ piece (diameter 18mm, first level red, optical path difference 551nm)/4 pieces (diameter 18mm, optical path difference 147.3nm)
Quartz wedge (12x28mm, grade I-IV)
8. Focusing system: Coaxial coarse and fine adjustment with limit and adjusting elastic device, with a grid value of 0.002mm
9. Electric light source: 6V/20W halogen lamp (adjustable brightness)
4、 Hot table:
1. Microscopic precision temperature controller
The working temperature under the 20X objective lens can reach up to 300 ℃, and the temperature operation program is fully automatically controlled; The temperature program segment is set by the user themselves, with 30 temperature programming segments and cyclic operation, which can accurately reflect the set temperature, furnace core temperature, and actual temperature of the sample. Set the starting temperature for each segment, and the duration that can be maintained within that segment. The heating rate can be adjusted, with an accuracy of ± 0.3 ℃ and a memory point reading.
2. Microscopic heating platform
It can move with the stage, has a large heating area in the working area, adjustable transparent area, and a temperature gradient in the working area below ± 0.1
Starting temperature: room temperature
The heating area in the workspace should be at least 1X1cm
The temperature gradient in the workspace does not exceed ± 0.1oC
Transparent area of 2mm or more, adjustable
The error between the displayed temperature and the actual temperature shall not exceed ± 0.2
The hot stage can move with the carrier stage
When the melting point measurement temperature exceeds 100 degrees, the working distance of the 25X objective lens is too close, which can easily damage the lens. Please choose long working distance 20X and 40X objective lenses
5、 System composition:
Computerized Polarization Thermal Stage (XPN-203E): 1. Polarization Microscope 2. Thermal Stage 3. Camera (CCD) 4. A/D (Image Acquisition) 5. Computer
Digital Polarized Thermal Stage (XPN-203Z): 1. Polarized Microscope 2. Thermal Stage 3. Digital Camera System
Digital microscopy imaging system Computer microscopy imaging system
6、 Optional parts for the instrument:
1. High pixel imaging system 2. Polarization microscope analysis software
Factory laboratory selection Selection of University Laboratories
Typical application legend Instrument diagram explanation