Polarization microscope melting point analyzer XPN-300
Polarization Microscope Melting Point Analyzer XPN-300 I. Purpose: XPN-300 Polarization Microscope Melting Point Analyzer and Polarization Temperature
Product details
Polarized microscope melting point analyzerXPN-300
1、 Purpose:
The XPN-300 polarizing microscope melting point analyzer and polarizing temperature controller are the most commonly used professional experimental instruments in geological, mineral, metallurgical and related higher education departments. Polarized microscope can be used by a wide range of users for single polarization observation, orthogonal polarization observation, cone light observation, and microscopic photography, to observe the deformation, color change, and three state transformation of objects under heating. Polarized microscope is equipped with gypsum λ, mica λ/4 test pieces, quartz wedges, and movable rulers, and can also be used in fields such as chemical fiber, semiconductor industry, and drug inspection. The polarization melting point tester adopts microcomputer detection, with automatic P, I, D adjustment and fuzzy manual adjustment functions. The polarization melting point tester displays the temperature value and set temperature value through LED.
2、 System Introduction:
The polarizing microscope melting point analyzer system is a high-tech product developed by perfectly combining precision optical microscope technology, advanced photoelectric conversion technology, and cutting-edge computer image processing technology. Real time dynamic images can be easily observed on the display screen, and the required images can be edited, saved, and printed.
3、 Technical parameters:
1. Eyepiece
Category magnification Field of view (mm)
Flat field eyepiece 10X φ22
Cross shaped eyepiece 10X φ20

2. Objective lens
Category magnification Numerical aperture (NA) Working distance (mm) Cover glass thickness (mm)
Objective lens 4X 0.10 7.18 -
10X 0.25 4.70 0.17
40X 0.65 0.72 0.17
60X 0.85 0.18 0.17
Computer polarization melting point testerXPN-300E
View large image
Digital Polarization Melting Point TesterXPN-300Z
View large image
3. Magnification factor: 40X 100X 400X 600X
System magnification: 40X-2600X
4. Numerical aperture of spotlight: NA1.2/0.22 shake out achromatic spotlight with adjustable center
5. Polarizing mirror: adjustable vibration direction of 360 °, with locking device, movable optical path
6. Polarizer: can move out of the light path, with a rotation range of 90 °, built-in Burgundy mirror, and adjustable center
7. Compensator: λ plate (Ø 18mm, first level red, optical path difference 551nm)
λ/4 pieces (Ø 18mm, optical path difference 147.3nm)
Quartz wedge (12x28mm, grade I-IV)
8. Focusing system: Coaxial coarse micro motion with limit and adjustment of tension device, micro motion grid value of 0.002mm
9. Electric light source: 6V/20W halogen lamp (adjustable brightness)
10. Anti mold: Unique anti mold system
4、 Polarized melting point tester
1. Polarized melting point tester
The working temperature under the 20X objective lens can reach up to 300 ℃, and the temperature operation program is fully automatically controlled; The temperature program segment is set by the user themselves, with 30 temperature programming segments and cyclic operation, which can accurately reflect the set temperature, furnace core temperature, and actual temperature of the sample. Set the starting temperature for each segment, and the duration that can be maintained within that segment. The heating rate can be adjusted, with an accuracy of ± 0.3 ℃ and a memory point reading.
2. Microscopic heating platform
It can move with the stage, has a large heating area in the working area, adjustable transparent area, and a temperature gradient in the working area below ± 0.1
Starting temperature: room temperature
The heating area in the workspace should be at least 1X1cm
The temperature gradient in the workspace does not exceed ± 0.1oC
Transparent area of 2mm or more, adjustable
The error between the displayed temperature and the actual temperature shall not exceed ± 0.2
The hot stage can move with the carrier stage
When the melting point measurement temperature exceeds 100 degrees, the working distance of the 25X objective lens is too close, which can easily damage the lens. Please choose long working distance 20X and 40X objective lenses
5、 System composition:
Computerized high-precision polarizing microscope (XPN-300E): 1. Microscope 2. Melting point analyzer 3. Camera (CCD) 4. A/D (image acquisition) 5. Computer
Digital camera type high-precision polarizing microscope (XPN-300Z): 1. Microscope 2. Melting point analyzer 3. Digital camera
Digital microscopy imaging system Computer microscopy imaging system
6、 Optional parts:
1. High pixel imaging system 2. Polarization microscope analysis software 3. Objective lens: 20X
Factory laboratory selection Selection of University Laboratories
Typical application legend Instrument diagram explanation