Beidou instrument portable carbon dioxide gas detector? Can perform real-time data monitoring, recording, storage, USB copying, curve analysis, and al
Product details

pBD5-GA4120-CO2-2015S4Portable carbon dioxide gas detectorPrinciple: Infrared sensor

Beidou Satellite InstrumentPortable carbon dioxide gas detectorProduct specifications:

  • Detection range: 0~20/50/75/100%;
  • Temperature drift:< 0.1%FS/°C;
  • Working temperature: 0 to 50°C;
  • ambient humidity: 0~95%;
  • Accuracy: 0 to 50%±1%;
  • Repetition accuracy: ± 0.2%

Carbon dioxide gas detectorTechnical parameters:

  • It can perform real-time data monitoring, recording, storage, USB copying, curve analysis, and alarm.
  • Display range:-9999~9999The decimal point position can be set
  • Basic error: less than ± 0.2% F.S
  • Measurement control cycle: 0.2 seconds per channel
  • Display resolution: 0.1/0.01
  • Measurement control cycle: 0.2 seconds per channel
  • Record interval:1 second~59 minutes and 59 seconds can be set arbitrarily, with the option to choose between cyclic and non cyclic recording、 RS485 interface

Carbon dioxide gas detector

Manufacturer: Beijing Beidouxing Industrial Chemistry Research Institute

Beijing Beidouxing Technology Co., Ltd

Carbon dioxide gas detectorProduct specifications:

  • Detection range: 0~20/50/75/100%;
  • Temperature drift:< 0.1%FS/°C;
  • Working temperature: 0 to 50°C;
  • ambient humidity: 0~95%;
  • Accuracy: 0 to 50%±1%;
  • Repetition accuracy: ± 0.2%

Carbon dioxide gas detectorTechnical parameters:

  • It can perform real-time data monitoring, recording, storage, USB copying, curve analysis, and alarm.
  • Display range:-9999~9999The decimal point position can be set
  • Basic error: less than ± 0.2% F.S
  • Measurement control cycle: 0.2 seconds per channel
  • Display resolution: 0.1/0.01
  • Measurement control cycle: 0.2 seconds per channel
  • Record interval:1 second~59 minutes and 59 seconds can be set arbitrarily, with the option to choose between cyclic and non cyclic recording、 RS485 interface