Price of push flow submersible mixer, QJB5.5/12-620/3-480S, Submersible jet mixer
Jiangsu Du'an Environmental ProtectionSubmersible mixer model, rated power, rated current, impeller diameter, impeller speed(r/min) Weight (kg)
(kw)(A)(mm)
Casting mixerQJBO.85/8-260/3-740/C/S
QJB1.5/6-260/3-960/c/S
QJB2.2/8-320/3-740/c/s
QJB4/6-320/3-960/c/s、
QJB5.5/4-670/3-295/c/s
QJB7.5/4-670/3-330/c/s
QJB11/4-790/3-303/c/s
QJB15/4-790/3-360/c/s
Stamping mixerQJB1.5/8-400/3-740/S
QJB2.5/8-400/3-740/s
QJB3/8-400/3-740/s
QJB4/12-615/3-480/s
QJB5/12-615/3-480/s
QJB7.5/12-615/3-480/s
QJB10/12-615/3-480/s
Low-speed thrusterQJB3/2-1100/2-135/P
QJB1.5/4-1800/2-42/P
QJB2.2/4-1800/2-50/P
QJB3/4-1800/2-56/P
QJB4/4-1800/2-65/P
QJB1.5/4-2500/2-36/P
QJB4/4-2500/2-42/P
QJB5/4-2500/2-56/P
Ordering instructions for QJB submersible mixer:
Please provide the following detailed data:1. The product name and model of the submersible mixer; 2. The impeller speed of the submersible mixer (r/min); 3. Submersible mixer impeller diameter (mm); 4. Submersible mixer motor power (KW); 5. Submersible mixer thrust (N); 6. Material requirements for submersible mixer (C-cast iron S-stainless steel P-polyurethane AL aluminum); 7. Depth of installation system for submersible mixer (m); 8. Does the submersible mixer require a deflector cover; 9. Is the submersible mixer equipped with a control cabinet; 10. Does the submersible mixer come with other accessories so that we can select the right one for you.
Working principle and applicable requirements of submersible mixer
Nowadays, most of the mixers are used in some sewage treatment equipment, and the mixers we see are basically the large cement mixers on construction sites. In fact, there are many smaller mixers used in water plants or sewage treatment plants nowadays, and among themagitatorsIt belongs to the mainstream category. Here is an introduction to the working principle and applicable requirements of this submersible mixer.
The main working principle of current submersible mixers is that the internal stirring impeller of the machine rotates and stirs the liquid under the drive of the motor, generating a rotating jet. The shear stress along the surface of the jet is used for mixing, causing the liquid outside the flow field to generate stirring effect through friction. At the same time, a volumetric flow is formed during extreme mixing, and a large volume flow mode is applied to achieve controlled fluid transportation. And it is precisely because of its principle that this submersible agitator is suitable for mixing process sludge water in industrial wastewater treatment plants such as sludge concentration tanks, anaerobic tanks, and biochemical sludge storage tanks. And the submersible mixer should work continuously under fully submerged conditions. At the same time, it should be able to adapt to the working conditions of continuous operation, intermittent operation, and resuming operation after a long-term stop.
Jiangsu Du'an Environmental Protection Submersible Mixer recommends daily inspections and maintenance for users:
Blender and visible components during installation |
Replace or repair worn and damaged parts. Check if all screws, bolts, and nuts are tightened. Check the condition of the lifting equipment's shackles, hanging chains, etc. Check if the guide rod is vertical. |
Quantity of oil |
Check the fuel level and add oil as needed. |
Oil situation |
Insert a tube into the oil hole, press down on the upper end of the tube, and remove a small amount of oil from the bottom. If the oil has been emulsified or contains too much water, the oil should be replaced. Check again after changing the oil and running for one week. If the oil emulsifies again or contains excessive water, the seals should be checked and replaced if necessary. Please contact our maintenance department. |
cable entry |
Ensure that the cable entry is securely fastened. If the cable inlet leaks, the cable should be replaced in a timely manner. |
cable |
If the cable sheath is damaged, please replace the cable. |
Starting equipment |
If there is a malfunction in the starting equipment, please contact an electrical engineer. |
Monitoring equipment |
It is necessary to regularly check whether the monitoring equipment is accurate; Whether the display function of the signal is intact; Whether the short-circuit, open circuit, and overload protection functions are reliable; Whether the connections between equipment components are firm; If there is a malfunction, it should be repaired or replaced immediately. |
Rotation direction of impeller (voltage required) |
If the rotation direction is incorrect, replace the two phase wires. Every time the motor is reconnected, the direction of rotation should be checked. |
Guide rods and others |
Check and repair the malfunction |
Insulation resistance in stator |
Use a 0-500 megohmmeter to measure the insulation resistance between any phase wire and ground wire, which should not be less than 50 megohms. |
For detailed product sample information, please contact us by phone. We welcome friends from all walks of life to visit our company for business negotiations.