Main technical parameters:
1. Spray nozzle: single station independent stainless steel nozzle;
2. Spray reagent: Dissolve 500mL of water and 5g of phenolphthalein in 500mL of methanol;
3. Spray speed: 20-30ml/min;
4. Spray distance: 600mm;
5. Spray pressure: vacuum pump pressure control, constant pressure adjustable;
6. Spray flow: (0.5 ± 0.1) mm/min Within ± 2 seconds;
7. Spray time: 10 seconds;
8. Test head mold: made of silicone material;
9. Head mold clockwise or counterclockwise rotation: 90 °;
10. Covering velvet fabric: surface quality 185g/㎡;
11. Interval test paper: approximately 180 mm x 100 mm white water paper, immersed in a 0.1mol/L sodium carbonate solution;
12. The inner box is made of stainless steel and equipped with drainage and water storage devices;
13. The outer box is made of steel spray painted, with casters installed at the bottom and an observation window;
14. Equipment power supply: AC220V 50Hz。