Radioactive drug nuclide concentration measuring instrument (high-purity germanium)
The FYND-50L radioactive drug activity concentration measuring instrument consists of a high-purity germanium gamma spectrometer, a Dewar flask, a dig
Product details

Brief introduction

FYND-50L RadiationSexual drugsactivity concentrationmeasureInstrument byHPGeγspectrometerDuwaBottles, digital multi-channel, low background lead chamberComputersDrug release nucleuswhiteactivityconcentrationanalysisSpecial softwareComposed of passive efficiency calibration software, etc, as shown in the picture1,It is the first specialized measurement system for radioactive nuclide activity concentration in ChinatallPure germanium spectrometer.

FYND-50LofThe main functions are

  • Spectral acquisition and fully automated spectral analysis (see Figure 2);
  • It has functions such as login, password management, user management, measurement log management, warning modification, and operation authorization management (see Figure 3);
  • Automatically generate a report on nuclide activity concentration (see Figure 4).

FYND-50LThe measurement accuracy has been verified by a national first-class metrology station and meets national standards.FYND-50LThe software interfaceAs shown in the picture2FYND-50LofAnalysis report as shown in the figure3.

pictureFYND-50L radiationSexual drugsactivity concentrationmeasureinstrument

IIapplication area

Drug productionMeasurement of nuclide activity concentration by units and drug dispensing departments.


IIIFYND-50Ltypicalperformance index

  • Under the condition of configuring a 60% relative detection efficiency detector, the minimum detection limit for F-18 is 0.5Bq/L for 10 minutes and 0.25Bq/L for 30 minutes.
  • Detector: High purity germanium detectors with relative detection efficiency ranging from 40% to 100% are optional;
  • Refrigeration: Liquid nitrogen condensation refrigeration and liquid nitrogen refrigeration are optional;
  • 10cm low background lead 4 π direction shielding;
  • Weight: 1 1 ton.

4technologycharacteristic

  • Fully automatic operation from energy scale to measurement result report;
  • The measurement program and content comply with relevant standards and have authority.


picture2 softwareOne of the interfaces

picture3 logQuery and modify warning interface

Figure 4: Radioactive Nuclear Purity Analysis Report

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!