Specialized separation column for baseline separation of volatile amines? Does the inertness ensure accuracy and sensitivity in the analysis of volati
Product details

Rtx®-Volatile amine fused quartz column

·Specialized separation column for baseline separation of volatile amines
·The inertness ensures accuracy and sensitivity in the analysis of volatile amines, including free amines
·The highly stable fixed phase resists the impact of repeated water injection, thereby extending the service life of the column
·high heat resistance(290 °C)Ensured the amine fromC16Upwash to remove dirt and debris at high temperatures
Similar to fixed phase:direct substitutionCP-Volamine,Analyzing thick films of aminesCP-Sil 8,Other surface packages with low polarityPolysiloxane andColumn for amine passivation

order No#
length
inside diameter
unit
18076
15m
0.32mm
ea.
18077
30m
0.32mm
ea.
18078
60m
0.32mm
ea.
Showing 1 to 3 of 3 entries
Description:
·Specialized separation column for baseline separation of volatile amines
·The inertness ensures accuracy and sensitivity in the analysis of volatile amines, including free amines
·The highly stable fixed phase resists the impact of repeated water injection, thereby extending the service life of the column
·high heat resistance(290 °C)Ensured the amine fromC16Upwash to remove dirt and debris at high temperatures
Rtx®-The volatile amine column is specifically designed to analyze volatile amines in difficult matrices such as water. The unique base passivation effect creates a special surface layer that is inert to active compounds, resulting in uniform peaks in the low detection range. The stable bonding of the stationary phase not only enables the column to retain the analyte and exhibit high selectivity, but alsoThe highly stable fixed phase resisted the impact of repeated water injectionBy comparing conventional volatile amines analyzed by customers, Rtx®-The effect of volatile amine columns is particularly better in peak shape and service life compared to other amine specific columns. Each Rtx®-The volatile amine column follows strict quality standards and is tested using a specially designed detection mixture containing basic compounds to ensure the column's inertness, stability, and repeatability. These quality controls ensure consistent quality of the column, enabling Rtx®-Volatile amine column has become the best choice for volatile amine analysis.