Zhejiang Danone Technology Co., Ltd
Home>Products>SC-K610 switchgear intelligent control device (ordinary type)
SC-K610 switchgear intelligent control device (ordinary type)
The SC-K610 series switchgear intelligent control device is suitable for 3-35KV indoor switchgear such as central cabinets, handcart cabinets, fixed c
Product details

product overview

The SC-K610 series switchgear intelligent control device is suitable for 3-35KV indoor switchgear such as central cabinets, handcart cabinets, fixed cabinets, and contact cabinets. It has functions such as dynamic simulation display, voice error prevention prompt, cabinet heating control, high-voltage live display and locking, remote/local operation, opening/closing operation, lighting operation, opening/closing indication, energy storage indication and RS485 communication interface. The ultra-thin body saves instrument space and effectively improves the quality of the switchgear.

Users can choose RS485 (MODBUS protocol) communication function as needed, which enables remote signaling, telemetry, and control of the site through RS485 communication.

Introduction to Technical Parameters and Functions

Power Supply: AC220V±10%; 50HZ

Power consumption: ≤ 10W

Usage environment: Temperature -25-70 ℃, relative humidity ≤ 95% RH

Electrical strength: The distance between the shell and the terminal is greater than AC200OV

Insulation performance: greater than 100M Ω between the shell and the terminal

Simulation instructions:

Circuit breaker status indication (no floating contact input): When closing, the closing contact closes and the red analog bar lights up; When opening, the opening contact is closed and the green analog strip lights up.

Hand cart position indication (passive contact input): When the working position contact is closed, the red vertical analog bar lights up; Close the elbow at the experimental position, and the green horizontal simulation bar will light up.

Spring energy storage indicator (passive contact input): When the contact is closed, the red LED lights up, indicating energy storage; When the contact is disconnected, the green LED light is on, indicating that no energy has been stored.

Grounding switch position indication (passive contact input): When the contact is closed, the red analog bar lights up, indicating that the grounding is engaged; When the contact is disconnected, the green analog bar lights up, indicating that the grounding is disconnected.

Note: In the event of a power loss, all illuminated indicators do not light up, and the above contact signals are all from the auxiliary contacts of the circuit breaker.

High voltage live indication part

LED startup voltage (KV): Bus voltage x 0.15-0.65

Locking start control voltage (KV): Bus voltage x 0.65

When all three phases are not charged, the lock is released and the electric interlock operation is started.

Temperature and humidity control section

Number of sensor channels: SC-K210A has both condensation and temperature on one side; SC-K210B condensation in two channels, temperature in both channels;

Logical relationship: When the environmental humidity exceeds 88% RH and reaches the condition for condensation, heating is initiated; When the environmental humidity no longer meets the condensation conditions, the device automatically stops heating; Temperature control accuracy ± 5% RH;

When the ambient temperature is below 6 ℃, the system starts heating. When the ambient temperature is above 16 ℃, the system automatically stops heating with a temperature control accuracy of ± 2 ℃;

Wire breakage alarm: When the heater breaks, the corresponding alarm indicator light will light up and the alarm output contact will close;

Forced heating: When the forced heating switch is in the manual position, the heating output is unconditionally executed. In the automatic position, the device automatically operates according to the above control logic.

Voice anti error function

The circuit breaker is in the closed state, and the handcart is mistakenly pushed from the test position to the working position elbow, with a voice prompt of "please disconnect the circuit breaker";

The grounding switch is in the closed state, and the handcart was mistakenly pushed from the test position to the working position elbow. The voice prompt reads "Please disconnect the grounding switch"

The circuit breaker is closed and the grounding switch is turned on, causing the handcart to be mistakenly pushed from the test position to the working position. The voice prompts "Please disconnect the circuit breaker" and "Please disconnect the grounding switch".

Operation functions: compartment operation, energy storage operation, remote/local operation, cabinet lighting operation;

Optional feature: RS85 communication function.

External dimensions: 215x152x37mm hole size: 179x 119mm