Introduction to SGR type hot water pipeline pump:
Yongjia Quanda Pump and Valve Manufacturing Co., Ltd. offers direct sales from the manufacturer, with excellent quality and low prices!
The SGR series vertical hot water pipeline pump produced by Yongjia Quanda Pump and Valve Manufacturing Co., Ltd. is suitable for ordinary useSG pipeline booster pumpA new type of pump that has been improved based on customer needs, mainly solving the problem of low pipeline pressure, and has significant advantages compared to horizontal pipeline centrifugal pumps. Because this pump adopts advanced mechanical seals and the main shaft of the motor is directly installed on the impeller, it saves electricity, has high efficiency, small size and weight, compact structure, easy decoration, and can be used in series when flow and head are needed.
SGR type hot water pipeline pumpMain purpose:
1. SG pipeline booster pumpSuitable for high-rise building pressurized water supply, garden sprinkler irrigation, cooling tower water supply, long-distance water supply, air conditioning, refrigeration flushing, bathhouse and other cold and warm water circulation pressurization. Use temperatures below 80 ℃.2. SGR vertical hot water pipeline pumpSuitable for high-temperature hot water boosting circulation in heating, boilers, etc. Use temperatures below 150 ℃.
3. SGP corrosion-resistant pipeline pump is suitable for transporting corrosive media in the process flow of industries such as food, pharmaceuticals, wine making, and chemical engineering, with operating temperatures below 100 ℃.
4. SGB explosion-proof pipeline pumpSuitable for transporting non corrosive liquids, methane or coal mine underground fixed equipment Class I, and factory Class IIA, IIB, temperature groups T1, T2, T3, T4, and other industrial sites with explosive mixtures. Use temperatures below 80 ℃.
5. The SGPB corrosion-resistant and explosion-proof pipeline pump is suitable for transporting corrosive liquids in industries such as chemical, pharmaceutical, petroleum, food, and national defense, as well as methane or coal mine underground fixed equipment Class I and factory Class IIA and IIB, temperature groups T1, T2, T3, T4, and other industrial sites with explosive mixtures. Use temperatures below 150 ℃.
SGR type hot water pipeline pumpApplication conditions
The water pressure of the imported pipe should not exceed 3 kg/cubic centimeter and not be less than 0.2 kg/cubic centimeter. The water quality should be clean water, without fibers or solid particles. For hot water, it should be soft water; Medium temperature: not less than 0 ℃; The ambient temperature does not exceed ± 45 ℃; The power supply voltage is 380V, with some parts being 220V.
SGR type hot water pipeline pumpPerformance parameters:
Model
|
Caliber mm
|
Flow rate (m3/h)
|
Head mm
|
Efficiency%
|
Motor power Kw
|
Voltage v
|
Speed (r/min)
|
15SG0.6-5
|
15
|
0.6
|
5
|
60
|
0.04
|
220
|
2800
|
15SG1.8-10
|
15
|
1.8
|
10
|
60
|
0.12
|
220
|
2800
|
20SG2-8
|
20
|
2
|
8
|
60
tang |
0.12
|
220
|
2800
|
20SG3-14
|
20
|
3
|
14
|
60
|
0.25
|
220
|
2800
|
20SG3-30
|
20
|
3
|
30
|
60
|
0.75
|
220
|
2800
|
25SG2.5-15
|
25
|
2.5
|
15
|
60
|
0.25
|
220
|
2800
|
25SG4-20
|
25
|
4
|
20
|
60
|
0.75
|
220
|
2800
|
25SG3-30
|
25
|
3
|
30
|
60
|
0.75
|
220
|
2800
|
32SG5-20
|
32
|
5
|
20
|
60
|
0.75
|
220
|
2800
|
40SG5-8
|
40
|
5
|
8
|
60
|
0.75
|
220
|
2800
|
40SG6-20
|
40
|
6
|
20
|
60
|
0.75
|
220
|
2800
|
50SG10-7.5
|
50
|
10
|
7.5
|
55
|
0.75
|
220
|
2800
|
50SG10-15
|
50
|
10
|
15
|
60
|
0.75
|
220
|
2800
|
25SG4-20
|
25
|
4
|
20
|
60
|
0.75
|
380
|
2800
|
25SG3-30
|
25
|
3
|
30
|
60
|
0.75
|
380
|
2800
|
25SG6.5-30
|
25
|
6.5
|
30
|
60
|
1.5
|
380
|
2800
|
25SG10-50
|
25
|
10
|
50
|
60
|
4
|
380
|
2800
|
32SG5-20
|
32
|
5
|
20
|
60
|
0.75
|
380
|
2800
|
32SG8-30
|
32
|
8
|
30
|
65
|
1.5
|
380
|
2800
|
32SG15-40
|
32
|
15
|
40
|
60
|
4
|
380
|
2800
|
32SG12-50
|
32
|
12
|
50
|
60
|
4
|
380
|
2800
|
32SG14-80
|
32
|
14
|
80
|
60
|
0.75
|
380
|
2800
|
40SG6-20
|
40
|
6
|
20
|
60
|
0.75
|
380
|
2800
|
40SG9-30
|
40
|
9
|
30
|
65
|
1.5
|
380
|
2800
|
40SG18-40
|
40
|
18
|
40
|
60
|
4
|
380
|
2800
|
40SG15-50
|
40
|
15
|
50
|
70
|
4
|
380
|
2800
|
40SG18-65
|
40
|
18
|
65
|
65
|
7.5
|
380
|
2800
|
40SG15-80
|
40
|
15
|
80
|
65
|
7.5
|
380
|
2800
|
50SG10-7.5
|
50
|
10
|
7.5
|
55
|
0.75
|
380
|
2800
|
50SG10-15
|
50
|
10
|
15
|
60
|
0.75
|
380
|
2800
|
50SG12-25
|
50
|
12
|
25
|
65
|
1.5
|
380
|
2800
|
50SG15-30
|
50
|
15
|
30
|
65
|
2.2
|
380
|
2800
|
50SG18-40
|
50
|
18
|
40
|
65
|
4
|
380
|
2800
|
50SG16-50
|
50
|
16
|
50
|
65
|
4
|
380
|
2800
|
50SG20-65
|
50
|
20
|
65
|
65
|
7.5
|
380
|
2800
|
50SG25-80
|
50
|
25
|
80
|
65
|
15
|
380
|
2800
|
50SG30-100
|
50
|
30
|
100
|
65
|
22
|
380
|
2800
|
65SG30-15
|
65
|
30
|
15
|
65
|
2.2
|
380
|
2800
|
65SG30-27
|
65
|
30
|
27
|
65
|
4
|
380
|
2800
|
65SG40-40
|
65
|
40
|
40
|
65
|
7.5
|
380
|
2800
|
65SG30-50
|
65
|
30
|
50
|
65
|
7.5
|
380
|
2800
|
65SG50-65
|
65
|
50
|
65
|
65
|
15
|
380
|
2800
|
65SG40-80
|
65
|
40
|
80
|
65
|
18.5
|
380
|
2800
|
65SG45-100
|
65
|
45
|
100
|
65
|
22
|
380
|
2800
|
80SG35-20
|
80
|
35
|
20
|
65
|
4
|
380
|
2800
|
80SG50-30
|
80
|
50
|
30
|
65
|
7.5
|
380
|
2800
|
80SG70-40
|
80
|
70
|
40
|
65
|
15
|
380
|
2800
|
80SG60-50
|
80
|
60
|
50
|
65
|
15
|
380
|
2800
|
80SG80-65
|
80
|
80
|
65
|
65
|
22
|
380
|
2800
|
80SG70-80
|
80
|
70
|
80
|
65
|
22
|
380
|
2800
|
80SG55-100
|
80
|
55
|
100
|
65
|
30
|
380
|
2800
|
100SG40-18
|
100
|
40
|
18
|
65
|
4
|
380
|
2800
|
100SG50-30
|
100
|
50
|
30
|
65
|
7.5
|
380
|
2800
|
100SG70-40
|
100
|
70
|
40
|
65
|
15
|
380
|
2800
|
100SG60-50
|
100
|
60
|
50
|
70
|
15
|
380
|
2800
|
100SG80-65
|
100
|
80
|
65
|
70
|
22
|
380
|
2800
|
100SG75-78
|
100
|
75
|
78
|
70
|
22
|
380
|
2800
|
100SG100-60
|
100
|
100
|
60
|
70
|
30
|
380
|
2800
|
100SG65-100
|
100
|
65
|
100
|
70
|
30
|
380
|
2850
|
125SG80-18
|
125
|
80
|
18
|
70
|
7.5
|
380
|
1450
|
150SG100-15
|
150
|
100
|
15
|
70
|
7.5
|
380
|
1450
|
150SG140-26
|
150
|
140
|
26
|
70
|
18.5
|
380
|
1450
|
150SG160-40
|
150
|
160
|
40
|
70
|
30
|
380
|
2800
|
150SG200-50
|
150
|
200
|
50
|
70
|
37
|
380
|
2800
|
150SG220-65
|
150
|
170
|
65
|
70
|
55.5
|
380
|
2800
|
150SG170-180
|
150
|
200
|
180
|
70
|
55.5
|
380
|
2800
|
200SG200-20
|
200
|
200
|
20
|
70
|
18.5
|
380
|
1450
|
200SG200-35
|
200
|
200
|
35
|
70
|
30
|
380
|
2800
|
200SG200-44
|
200
|
200
|
44
|
70
|
37
|
380
|
2800
|
200SG240-60
|
200
|
240
|
60
|
70
|
55.5
|
380
|
2800
|
200SG200-75
|
200
|
200
|
75
|
70
|
55.5
|
380
|
2800
|
250SG380-22
|
250
|
380
|
22
|
70
|
37
|
380
|
1450
|
250SG500-30
|
250
|
500
|
30
|
70
|
55
|
380
|
1450
|
300SG400-20
|
300
|
400
|
20
|
70
|
37
|
380
|
1450
|
300SG500-30
|
300
|
500
|
30
|
70
|
55
|
380
|
1450
|
350SG800-20
|
350
|
800
|
20
|
70
|
55
|
380
|
1450
|
400SG1000-18
|
400
|
1000
|
18
|
70
|
55
|
380
|
1450
|
500SG1200-15
|
500
|
1200
|
15
|
70
|
55
|
380
|
1450
|
500SG800-20
|
500
|
800
|
20
|
70
|
55
|
380
|
1450
|
Assembly and disassembly
1. Clean all the components to be installed.
2. Install a mechanical seal on the motor spindle, and add a small amount of clean turbine oil or No. 20 engine oil on the surface where the mechanical seal's dynamic and static rings match.
3. Install the impeller and tighten it with the impeller nut.
4. Install the '0' ring and tighten the pump body and motor end cover with bolts. Pay attention to maintaining a clearance of 25.05mm between the impeller front cover plate and the pump body, and ensure a certain operating clearance between the impeller inlet outer ring and the pump body.
5. The disassembly sequence is opposite to this.
Installment and use
1. Use rubber washers and bolts to connect the flanges at both ends of the pump body to the pipeline flange, completing the installation. For the convenience of use and maintenance, a regulating valve should be installed on both the inlet and outlet pipelines of the pump.
2. Open the inlet regulating valve to allow water to enter the pump to keep the sealed chamber filled with liquid (otherwise it will damage the seal), and close the outlet valve.
3. Connect the power and jog to confirm the correct direction.
4. After the steering is confirmed, start and operate the pump.
Adjust the opening of the outlet valve to operate the pump near the design point, based on the rated flow rate and head of the pump For this, it is best to install a pressure gauge near the outlet flange. Attention: This pump is strictly prohibited from running without water to avoid damaging the seals.
Troubleshooting
fault |
reason |
Troubleshooting |
1. The water pump is not producing water |
The water injected into the water pump is insufficient, the rotation direction is incorrect, and the impeller flow channel is blocked. |
Inject water into the water pump again, pass it through the impeller channel, and adjust the direction of rotation. |
2. Insufficient water pump flow |
The water pump is partially clogged, the speed is too low, the total head is higher than the rated value of the pump, and the impeller is damaged. |
Clean the water pump and pipes, replace the impeller, increase the speed of the water pump shaft, and adjust the outlet valve. |
3. Insufficient export pressure |
There is air in the liquid, the speed is too low, the impeller is damaged, and the outlet valve is too wide open. |
Remove air from the liquid, increase the pump speed, replace the impeller, and adjust the outlet valve. |
4. The pump consumes too much power (the motor heats up) |
Mechanical defects such as insufficient running clearance, bent motor shaft, loose bolts, etc., and the pump working at too high a flow rate, i.e. the pump working at a head far below the rated head. |
Check? The mechanical part should be adjusted and processed in a timely manner, and the outlet valve should be adjusted to make the pump work near the rated flow rate and head. |
5. Pump vibration |
The pipeline system is not well supported, and the impeller is partially blocked causing imbalance, resulting in cavitation and air in the liquid. |
Check? Pump support department, tighten the nut, connect the impeller to balance it, and eliminate air exchange. |
6. Water pump leakage |
Mechanical seal damage, O-ring damage, pump body leakage. |
Replace the mechanical seal and O-ring, and weld the leaking part of the pump body. |
7. Excessive noise from the water pump |
The bearings are overheated and lack oil, and the water pump is overloaded. |
Add oil to the bearing and eliminate according to 4. |
SGR type hot water pipeline pumpPlease provide as much as possible for ordering:
1. Model 2. Diameter 3. Head (m) 4. Flow rate 5. Motor power (KW) 6. Speed (R/min) 7. Material without accessories 8. Voltage (V)
Welcome to visit our Quanda Pump Valve【www.quandabf.cn】If you have any questions You can call us and we will do our best to provide you with high-quality service.