Beijing Zhongke Environmental Testing Instrument Co., Ltd
Home>Products>SN-T Full Spectrum (Spray Type) Xenon Arc Lamp Aging Test Chamber
SN-T Full Spectrum (Spray Type) Xenon Arc Lamp Aging Test Chamber
SN-T Full Spectrum (Spray Type) Xenon Arc Lamp Aging Test Chamber Product Usage: This product uses a xenon arc lamp that can simulate the full spectru
Product details

SN-T Full Spectrum (Spray Type) Xenon Arc Lamp Aging Test Chamber

Product use: Xenon lamp weather resistance test chamber can simulate various environmental factors such as light exposure, rain, temperature and humidity, condensation, etc., and can be independently adjusted; Xenon lamps are used as light sources, which have a spectral distribution similar to sunlight. Therefore, in science, xenon lamp light is used to simulate sunlight for lighting experiments; At the same time, there is a wide range of temperature and humidity regulation for adjustment; The rain adopts an independent circulation system, so when necessary, harmful gas substances can be added to the water supply source of the rain, the cooling water temperature of the sample rack can be changed, and the condensation amount and surface temperature of the sample can be adjusted. Therefore, this test chamber can be used for a combination test of multi factor weather resistance.

Scope of application: To evaluate the light and weather resistance of certain materials under high-temperature light sources by conducting aging tests on material samples exposed to xenon arc lamp light and thermal radiation. It is mainly used for paints, coatings, rubber, plastics, pigments, waterproof materials, adhesives, fabrics, etc.

Compliant with standards: This test chamber is designed and manufactured strictly in accordance with relevant standards such as GB/T16422.2-2014 and GB/T14522-2008;

1、 Product Model and Parameters

PRODUCT MODEL SN-T
Internal dimensions D × W × H 350×500×350: mm
Dimensions D × W × H 550×850×650: mm
Black panel temperature 65℃~100℃±2℃
Sample tray size 251×460mm
Constant temperature fluctuation ≤±0.5℃
temperature uniformity ≤2.0℃
glass filter 1 piece
Xenon lamp source Air-cooled lamp tube
Total number of lamps 2 (including 1 spare)
Spray cycle 48min/12min or 102min/18min (stop/spray time)
Rainwater pressure 0.12~0.15Mpa
Spray nozzle aperture Ф0.8mm
Lamp wattage 2.5KW x 1 unit
Distance between sample rack and lamp tube 230~280mm
radiance

Average irradiance 550W/㎡ (irradiance adjustable)

Handheld or installation type radiometer (optional)

Time setting range 0-9999 hours
Power requirements AC220V(±10%)/50HZ

2、 Box material:
1. The shell is made of 1.2mm thick A3 steel plate and processed by CNC machine. The surface of the shell is treated with anti-static spray coating, which makes it more smooth and beautiful;
2. The inner liner is made of SUS304 stainless steel plate;
3. The mixing system adopts a long axis fan motor and a high-temperature resistant stainless steel multi blade impeller to achieve strong convection and vertical diffusion circulation;
4. High temperature resistant sealing strips are used between the door and the box to ensure the sealing of the testing area;
5. Adopting a reaction door handle makes operation easier;
3、 Control system:
1. The temperature instrument adopts an intelligent Korean imported temperature control instrument with a control accuracy of ± 0.1 ℃;
2. The time display adopts a high-precision digital display microcomputer integrated controller imported from South Korea;
3. The temperature control output power is calculated by a microcomputer to achieve high-precision and high-efficiency electricity efficiency;
SN-T Full Spectrum (Spray Type) Xenon Arc Lamp Aging Test Chamber
4、 Heating system:
1. Adopting far-infrared stainless steel high-speed heating electric heater;
2. High temperature and light independent system (non interfering with each other);
3. The temperature control output power is calculated by a microcomputer to achieve high-precision and high-efficiency electricity efficiency;
5、 Lighting system:
1. Blackboard thermometer: metal blackboard thermometer;
2. Xenon arc lamp: The service life of the lamp is 1800-2000 hours;
3. Irradiance control: manual or automatic adjustment (optional)
6、 Spray water circulation system:
1. Water quality: tap water (solid content less than 20ppm);
2. The spray pressure can be adjusted between 0.12 and 0.15 Mpa;
3. Two nozzles were installed at the top of the studio;
4. The sprayed water does not have recyclability;
7、 Equipment usage conditions:
1. Environmental temperature: 5 ℃~28 ℃ (average temperature within 24 hours ≤ 28 ℃)
2. Environmental humidity: ≤ 85%R.H
3. The operating environment requires good indoor ventilation, and no objects should be placed 50 centimeters in front, back, left, and right of the machine;