Model
|
Transmitter type (select only one)
|
DP
|
HP
|
GP
|
AP
|
SWP-T61DP
|
differential pressure transmitter
|
√
|
*
|
*
|
*
|
SWP-T61HP
|
High static pressure differential pressure transmitter
|
*
|
√
|
*
|
*
|
SWP-T61GP
|
Gauge pressure transmitter
|
*
|
*
|
√
|
*
|
SWP-T61AP
|
Absolute pressure transmitter
|
*
|
*
|
*
|
√
|
code
|
Pressure measurement range (URL) (select only one)
|
DP
|
HP
|
GP
|
AP
|
3
|
1.3~7.5KPa
|
√
|
√
|
√
|
√
|
4
|
6.2~37.4KPa
|
√
|
√
|
√
|
√
|
5
|
31.1~186.8KPa
|
√
|
√
|
√
|
√
|
6
|
117~690KPa
|
√
|
√
|
√
|
√
|
7
|
345~2068KPa
|
√
|
√
|
√
|
√
|
8
|
1170~6890KPa
|
√
|
*
|
√
|
√
|
9
|
3480~20680KPa
|
*
|
*
|
√
|
*
|
0
|
6890~41370KPa
|
*
|
*
|
√
|
*
|
code
|
Transmitter output (select only one)
|
DP
|
HP
|
GP
|
AP
|
E
|
4-20mA, linear, adjustable analog/damping
|
√
|
√
|
√
|
√
|
N
|
4-20mA, linear, digital type
|
√
|
√
|
√
|
√
|
S
|
4-20mA, intelligent type, HART protocol communication
|
√
|
√
|
√
|
√
|
code
|
Structural materials
|
DP
|
HP
|
GP
|
AP
|
Flanges/fittings
|
Drain/exhaust valve
|
diaphragm
|
22
|
316 stainless steel
|
316 stainless steel
|
316l stainless steel
|
√
|
√
|
√
|
√
|
23
|
316 stainless steel
|
316 stainless steel
|
Hastelloy C
|
√
|
√
|
√
|
√
|
24
|
316 stainless steel
|
316 stainless steel
|
Monel
|
√
|
√
|
√
|
√
|
25
|
316 stainless steel
|
316 stainless steel
|
tantalum
|
√
|
√
|
√
|
√
|
33
|
Hastelloy C
|
Hastelloy C
|
Hastelloy C
|
√
|
√
|
√
|
√
|
35
|
Hastelloy C
|
Hastelloy C
|
tantalum
|
√
|
√
|
√
|
√
|
44
|
Monel
|
Monel
|
Monel
|
√
|
√
|
√
|
√
|
code
|
Display header (choose not to fill in)
|
DP
|
HP
|
GP
|
AP
|
M1
|
Analog scale, linear meter head, 0-100% scale
|
√
|
√
|
√
|
√
|
M2
|
Simulated scale, square root indication, 0-10 scale
|
√
|
√
|
*
|
*
|
M3
|
LCD display, linear meter head, 0-100%, user selectable
|
√
|
√
|
√
|
√
|
code
|
mounting bracket
|
DP
|
HP
|
GP
|
AP
|
B1
|
Pipe installation bending bracket (pipe outer diameter Φ 50)~60)
|
√
|
√
|
√
|
√
|
B2
|
Board mounted bending bracket
|
√
|
√
|
√
|
√
|
B3
|
Pipe installation flat bracket (pipe outer diameter Φ 50)~60)
|
√
|
√
|
√
|
√
|
code
|
Relief Valve
|
DP
|
HP
|
GP
|
AP
|
D0
|
Back relief valve
|
√
|
√
|
√
|
√
|
D1
|
The side relief valve is located at the upper part of the pressure chamber
|
√
|
√
|
√
|
√
|
D2
|
The side relief valve is located at the lower part of the pressure chamber
|
√
|
√
|
√
|
√
|
code
|
Low pressure side flange adapter
|
DP
|
HP
|
GP
|
AP
|
N
|
No flange adapter
(1/4NPT female thread is used for pressure connection on the flange)
|
√
|
√
|
√
|
√
|
C1
|
1/2NPT female threaded flange adapter, impulse transition joint and welded impulse pipe
(Stainless steel)
|
√
|
√
|
√
|
√
|
C2
|
M20 × 1.5 male threaded flange adapter, pressure transition joint and welded pressure pipe
(Stainless steel)
|
√
|
√
|
√
|
√
|
code
|
Certification (ordinary type not filled in)
|
DP
|
HP
|
GP
|
AP
|
i
|
Intrinsic safety type, explosion-proof grade Exia II CT6
|
√
|
√
|
√
|
√
|
d
|
Explosion proof type, explosion-proof grade Exd II CT6
|
√
|
√
|
√
|
√
|
Typical model
|
SWP-T61 DP 4 S 22 M3 B3 D2 C2
|