SensION+MM374Desktop computerPHConductivity meter---------Huilong Huanke010-59483667
Popular keywords:SensION+MM374Desktop computerPHConductivity meter,SensION+MM374, desktopPHConductivity meter, Hash, Huilong Huanke, USA
SensION+MM374Desktop computerPHConductivity meterDetailed introduction:
Integrated workstation design, a system can meet the needs of multiple application scenarios
Integrated with the necessary accessories for laboratory work, testing is simple and easy to carry out
Industrial quality, waterproof keyboard design, longer service life
Large screen navigation menu, easy to operate
All models are equipped with built-in magnetic stirring devices.
Pre set electrode holder and position for placing calibration bottles.
Multi language operation manual: English, Spanish, French, Portuguese, Chinese.
All desktop components include:
Meter
Power supply (equipped with internationally recognized socket adapter).
electrode
Electrode holder (can be placed)1A or3Each electrode depends on the specific model.
Built in magnetic stirrer
Calibration beaker device
Calibration standards
Electrode storage solution
Instrument Operation Manual
Safety Manual——have18Multiple languages to choose from
Electrode Handbook
SensION+MM374Desktop computerPHConductivity meterProduct model and function:
pHMeasuring instrument:
|
PH3 |
PH31 |
MM340(pHandISEMeasuring instrument) |
Built in mixing control |
√ |
√ |
√ |
Re adjustment of temperature |
|
√ |
√ |
printer/Computer Output |
|
√ |
√ |
Single point, two-point, or three-pointpHcalibration |
√ |
√ |
√ |
Programmable calibration frequency |
√ |
√ |
√ |
Measurement limits (* maximum and * minimum) |
|
√ |
√ |
data log |
|
330A measurement value |
330A measurement value |
Electrode History |
|
√ |
√ |
In memorypHBuffer |
5species |
15species |
15species |
ORPcalibration |
220mV |
220mV |
220mV |
pHresolution |
0.01 |
0.01/0.1/0.001 |
0.01/0.1/0.001 |
mVresolution |
1 |
1/0.1 |
1/0.1 |
ISEmeasure |
|
|
4Calibration curves, each curve * has multiple5A standard for programmable settings. |
measurement channel |
1 |
1 |
2 |
Equipotential regulation(Iso-pH) |
|
√ |
√ |
sensION+Desktop electrochemical analyzerConductivity meter:
|
EC7 |
EC71 |
Built in mixing control |
√ |
√ |
Re adjustment of temperature |
|
√ |
printer/Computer Output |
|
√ |
Single point, two-point, or three-point calibration |
√ |
√ |
Programmable calibration frequency |
√ |
√ |
Automatic conductivity measurement range |
0.01μS/cm-500mS/cm |
0.001μS/cm-1000mS/cm |
data log |
|
400A measurement |
Linear adjustment of temperature correction0~9.99%/℃ |
√ |
√ |
Temperature correction of natural water bodies(ISO EN 27888) |
|
√ |
Optional reference temperature |
20perhaps25℃ |
20perhaps25℃ |
Adjustable reference temperature |
|
√(0~90℃) |
salinity measurement |
√ |
√ |
resistivity measurement |
√ |
√ |
TDSmeasure |
|
√ |
Measurement mode |
Stable measurement or continuous measurement |
Stable measurement, continuous measurement, or interval measurement |
Multi parameter measuring instrumentMM374——pH, ECandISE
Two measurement channels:pH+EC+℃/pHperhapsmVperhapsISE+℃
giveMM340andEC71Having the same characteristics.
thoroughfare1:
1Indicator electrode or composite electrode
1A reference electrode
1A conductivity cell+automatic temperature compensation
1A magnetic stirrer
thoroughfare2:
1Indicator electrode or composite electrode
1A reference electrode
1individualPt1000temperature probe
1A magnetic stirrer
sensION+Desktop electrochemical analyzerOrdering Guide:
SensION+PH3 |
PH/mv,℃ |
Basic desktop (universal)pHcomponent |
LPV2010T.97.002 |
5010T PHtemperature |
Suitable for general water quality analysis |
Superior desktop (dirty water sample)pHcomponent |
LPV2011T.97.002 |
5011T PHtemperature |
Suitable for measuring water samples with high solid content and viscous media |
||
Superior desktop (high-performance)pHcomponent |
LPV2014T.97.002 |
5014T PHtemperature |
Suitable for sulfur-containing materials,Reducing sugars or water samples that can react with silver ions |
||
Superior desktop (difficult to measure samples)pHcomponent |
LPV2021T.97.002 |
5021T PHtemperature |
Suitable for low ionic strength,colloidal state,Milk and paste like samples |
||
SensION+PH31(PH31conform toGLPStandard and equipped with data recording function |
Basic desktop (universal)pHcomponent |
LPV2110T.97.002 |
5010T PHtemperature |
Suitable for general water quality analysis |
|
Superior desktop (dirty water sample)pHcomponent |
LPV2111T.97.002 |
5011T PHtemperature |
Suitable for measuring water samples with high solid content and viscous media |
||
Superior desktop (high-performance)pHcomponent |
LPV2114T.97.002 |
5014T PHtemperature |
Suitable for sulfur-containing materials,Reducing sugars or water samples that can react with silver ions |
||
Superior desktop (difficult to measure samples)pHcomponent |
LPV2121T.97.002 |
5021T PHtemperature |
Suitable for low ionic strength,colloidal state,Milk and paste like samples |
||
SensION+PH340 GLPMeter |
PH/mv,ISE,℃ |
Basic desktop (universal)pHcomponent |
LPV2210.97.002 |
5010T PHtemperature |
Suitable for general water quality analysis |
Superior desktop (dirty water sample)pHcomponent |
LPV2211.97.002 |
5011T PHtemperature |
Suitable for measuring water samples with high solid content and viscous media |
||
Superior desktop (high-performance)pHcomponent |
LPV2214.97.002 |
5014T PHtemperature |
Suitable for sulfur-containing materials,Reducing sugars or water samples that can react with silver ions |
||
Superior desktop (difficult to measure samples)pHcomponent |
LPV2221.97.002 |
5021T PHtemperature |
Suitable for low ionic strength,colloidal state,Milk and paste like samples |
||
SensION+EC7 |
conductivity,total dissolved solids,salinity,℃ |
Basic desktop conductivity component |
LPV3070.97.002 |
5060conductance temperature |
Suitable for general water quality analysis |
SensION+EC71(EC71conform toGLPStandard and equipped with data recording function |
Superior desktop conductivity components |
LPV3170.97.002 |
5060conductance temperature |
Suitable for general water quality analysis |
|
SensION+MM374 GLPMeter |
PH/mv,conductivity, ISE,℃ |
Superior desktop (high-performance)PH/Conductivity component |
LPV4140.97.0002 |
5014T PHtemperature5070conductivity temperature |
Suitable for sulfur-containing materials,Reducing sugars or water samples that can react with silver ions |
SensION+MM374Desktop computerPHConductivity meter,Hash China's General Agent, Huilong Huanke's General Agent
24HHourly sales hotline:010-59483667
www.170086.com www.hach-wtw.com