Brief description: The MSM-100 series single channel CO detection system is a sampling gas analysis system, which includes two parts: a collection sys
Product details

Introduction to Single Channel CO Detection System
The MSM-100 series single channel CO detection system is a sampling gas analysis system, which includes two parts: a collection system and a measurement system. The sampling probe extracts a sample gas (a mixture of coal powder and air), which enters the refrigerator inside the analyzer through a sampling tube for cooling and dehumidification. The condensation generated during this process is sent out by a condensate peristaltic pump at a selected period. The heat released by the sample gas is dissipated through the heat sink on the outer wall of the chassis. The cooled and dehumidified gas then passes through a secondary particle filter to remove small particles, obtaining a clean and dry target gas. After analysis by sensors, the exhaust gas is discharged through the bottom of the chassis. This system is suitable for grinding equipment (coal mill), simple silo, coal powder silo, storage silo, raw coal silo, coarse/fine powder separator and other equipment.
characteristic:
Professional wear-resistant technology: The probe is made of welded alloy and has a nano level wear-resistant coating on the surface, which has high wear and corrosion resistance characteristics;
Excellent anti blocking technology: The probe adopts a non-standard shape that has undergone wind tunnel testing, the probe has a timed automatic blowback function, and the powder metallurgy alloy filter of the sleeve can effectively prevent coal powder particles with a diameter of more than 20 µ m from entering and fault (small flow) blowback;
Humanized warning function: The detection results are output to the control room, and the operator can observe the operation of the equipment at any time. The alarm setting function, simulation output, and alarm output function can take timely measures to effectively prevent fire and explosion, and can be connected to other control systems;
Reliable sensor poisoning prevention technology: The system adopts multi-stage flue gas filters, air-water separators, and chemical filters to effectively prevent sensor poisoning; The system adopts dual sensor technology, timed switching, timed calibration, effectively extends sensor life, and improves accuracy and zero stability;
Technical indicators
1Host
Range: (4-20) mg/L (can be selected according to the on-site environment);
Resolution: 1 mg/L;
Repeatability: ± 2% reading value;
Display mode: LCD liquid crystal display+LED at least light;
Analog output: (4-20) mA isolated output;
Relay output: CO high alarm, CO low alarm, system OK, system maintenance;
Automatic calibration relay: CO zero point and range calibration;
Zero point calibration: (air) 2 bar, clean and dry, flow rate 5L/min;
Cooling air: (2~10)bar、 Clean and dry, with a flow rate of 90L/min and an ambient temperature below 30 ℃, no cooling air is required;
Operating environment: (-40~55) ℃, (-40~25) ℃ without LCD display);
EMC: Complies with EM-61010-2
Power supply: 220V/55Hz
Power supply: 300W
Dimensions: 600mm x 630mm x 390mm (width x height x depth)
2Probe
Material: The external protective tube is made of synthetic steel (anti-corrosion and wear-resistant);
Filter: Stainless steel (replaceable);
Sampling probe temperature: below 600 ℃;
Work pressure: ± 10 inches of water column
Working length: 475mm/18in;
Installation: 3/4 ''/1501b ANSI;
Weight: Approximately 4.2kg;
3Sampling hose
Type: Reinforced nylon tube (standard);
Length: 25m (standard);
to configure
The system consists of a host, a probe, a blowback box, and a sampling hose.