Single phase rail type electric energy meter
Introduction: The DDS238-4 RS48 series single-phase all electronic energy meter adopts a dedicated large-scale integrated circuit, which has the chara
Product details

application

Product use

The DDS238-4 RS48 series single-phase all electronic energy meter adopts a dedicated large-scale integrated circuit, which has the characteristics of anti-theft, high accuracy, high overload, low power consumption, and light weight. Single phase AC active energy with a reference frequency of 50Hz or 60Hz can be measured. The electric energy meter is designed for fixed installation indoors, with an ambient temperature range of -40 ℃ to+70 ℃ and a relative temperature not exceeding 80%. This product complies with all technical requirements for single-phase energy meters in GB/T17215.321-2008 "Special Requirements for AC Measuring Equipment Part 21: Static Active Energy Meters (Class 1 and Class 2)".


TECHNICAL INDEX

Technical index



Equipped with a pulse counter

Equipped with pulse signal output terminals, users can connect them as needed




start

Start

The ammeter can continuously flash when the load current is 0.4% (level 1) or 0.5% (level 2) of the basic current under the conditions of reference voltage, reference frequency, and power factor of 1.


shunt running

Defluction

The electric energy meter has an anti submarine logic circuit. When there is no current in the current line and a reference voltage of 115% is applied, the output will not produce more than one pulse within ten times the time it takes to generate one pulse under the starting current.







Installment and use

Installation and use


The electric energy meter should be installed indoors, and the base plate for installing the electric energy meter should be fixed on a sturdy and fire-resistant wall. It is recommended to install it at a height of about 1.8 meters.

The electric energy meter should be wired according to the wiring diagram on the junction box, using copper wire or copper connectors for introduction.

Measures should be taken when using an electric energy meter in areas with frequent thunderstorms.

The LCD display of the energy meter shows the total active power

External dimensions and installation diagram



Load electricityflow

Power factor

error range

Level 1.0

Level 2.0

0.05Ib≤I<0.1Ib

1.0

Soil 1.5

Soil 2.0

0.1Ib≤I<>< span=''><>

1.0

Soil 1.0

Soil 2.0

0.1Ib≤I<0.2Ib

0.5(L)

Soil 1.5

Soil 2.5

0.8(C)

Soil 1.5

Soil 2.5

0.2Ib≤I<>< span=''><>

0.5(L)

Soil 1.0

Soil 2.0

0.8(C)

Soil 1.0

Soil 2.0


External dimensions and installation diagram

Wiring diagram





Technical Parameter

TECHNICAL PARAMETER

reference voltage

reference frequency

basic current

Meter constant imp/kWh

accuracy

220V

50Hz

1.5(6)A.25(10)A

5(20)A.5(30)A.5(40)A.

5(50)A.5(60)A.5(80)A.

5(100)A.10(40)A.

10(50)A.10(60)A.

10(800)A.10(60)A.

15(60)A.20(80)A.

30(100)A.

See nameplate

Level 1, Level 2


In addition, various specifications of electric energy meters can be made according to user needs


Basic error: Ib is the reference current, Imax is the current