Stainless steel electric contact pressure gauge
The instrument is equipped with upper and lower limit switch type contact devices, which send signals or turn on/off control circuits when the pressure reaches the set value, for automatic control or signaling of the operating system. The main components are made of OCr18Ni12Mo2Ti material, which is suitable for corrosive gas environments and can detect the pressure of highly corrosive media. It is widely used in industrial production processes such as machinery, chemical, petroleum, metallurgy, and power.
Technical parameters:
model
|
ZY-100BF/ZQ
|
ZY-150BF/ZQ
|
ZY-100BF
|
ZY-150BF
|
ZY-100BF/TQ
|
ZY-150BF/TQ
|
structural style
|
Axial belt front
|
Radial infinity
|
Front of radial belt
|
measuring range MPa
|
-0.1-0.15;- 0.1-0.3;- 0.1-0.5;- 0.1-0.9;- 0.1-1.5;- 0.1-2.4 0-0.25; 0-0.4; 0-0.6; 0-1.0; 0-1.6; 0-2.5; 0-4.0; 0-6.0; 0-10; 0-16; 0-25; 0-40; 0-60
|
Accuracy%
|
± 1.6
|
Contact electrical parameters
|
working voltage
|
380VAC; 220VDC
|
maximum operating current
|
1A
|
persistent current
|
0.6A
|
maximum power (No sensory load)
|
20VA
|
connector
|
X14K4P
|
Terminal Box
|
X14K4P
|
Terminal Box
|
X14K4P
|
Operating temperature:- 40℃~70℃ Upper limit of work pressure: not exceeding 2/3 of the instrument upper limit The vibration frequency of the working environment shall not exceed 25Hz, and the amplitude shall not exceed 0.5mm Instrument execution standard: Q/320211 DGH05-2004
External dimensions:

model
|
Dimensions mm
|
D
|
D1
|
D2
|
D3
|
A
|
B
|
C
|
E
|
d
|
d0
|
M
|
ZY-100
|
100
|
120
|
96
|
/
|
44
|
38
|
/
|
12.5
|
/
|
/
|
20×1.5
|
ZY-100ZQ
|
100
|
130
|
96
|
/
|
42
|
33
|
34
|
8.5
|
118
|
5.6
|
ZY-100TQ
|
100
|
125
|
96
|
102
|
44
|
38
|
/
|
9.5
|
118
|
5.6
|
ZY-150
|
150
|
164
|
136
|
/
|
50
|
44
|
/
|
16
|
/
|
/
|
ZY-150ZQ
|
150
|
177
|
136
|
/
|
50
|
43
|
55
|
14
|
165
|
5.6
|
ZY-150TQ
|
150
|
177
|
136
|
144
|
50
|
44
|
/
|
18
|
165
|
5.6
|
Usage and ordering instructions:
The working environment of the instrument should be free of corrosive gases. Please specify the name, model, and measurement range when placing an order. When low voltage and high current are present, it is advisable to use the HD type protective relay produced by our company.
|