Sanchang Instrument Professional ProductionStainless steel lined PTFE corrosion-resistant magnetic flap level gaugeHigh precision, fine workmanship, high quality, and long service life. buyStainless steel lined PTFE corrosion-resistant magnetic flap level gaugemanufacturerFind Sanchang Instrument.Baijiu level gaugeWholesale to Sanchang, inquireStainless steel lined PTFE corrosion-resistant magnetic flap level gaugeFind three options for price and selection of deaerator level gauge. Welcome to inquire! We will serve you wholeheartedly!
Stainless steel lined PTFE corrosion-resistant magnetic flap level gauge for usersIn the vast majority of cases, magnetic flap level gauges and magnetic float level gauges are chosenMagnetic level meterYes, it isStainless steel lined PTFE corrosion-resistant magnetic flap level gaugeThere are ordinary type, anti-corrosion type, heat tracing type, insulation type, high temperature type, high pressure type, high temperature and high pressure type, explosion-proof type, side mounted type, top mounted type, plug-in type, bottom mounted type, frost resistant type, etc
Stainless steel lined PTFE corrosion-resistant magnetic flap level gaugeIt can achieve high sealing, leak prevention, and safe and reliable measurement of liquid level under high temperature, high pressure, high viscosity, and strong corrosive conditions. The entire measurement process has no blind spots, prominent display, intuitive readings, and a large measurement range. Equipped with liquid level alarm and control switch, it can achieve upper and lower limit alarm and control of liquid level or boundary,Equipped with a liquid level transmitter, the liquid level boundary signal can be converted into a two-wire system4~20mADCThe standard signal enables remote detection, indication, recording, and control.Widely used for liquid level and boundary indication of various towers, tanks, tanks, spherical containers, and boiler equipment in industries such as petroleum, chemical, pharmaceutical, and food.
IIStainless steel lined PTFE corrosion-resistant magnetic flap level gaugeWorking principle of
A new type of instrument that uses magnetic steel inside a float to drive the flipping of a dual color thin sheet to indicate liquid level. The magnetic float inside the main body of the magnetic flap level gauge moves up and down with the rise and fall of the liquid level, while driving the dual color sheet inside the indicator outside the main body to flip,When there is a liquid level, it will turn red, and when there is no liquid level, it will turn white. The boundary between the red and white color bands represents the liquid level height. There is a prominent scale on the left side of the indicator. So as to make the liquid level indication appear clearer
IIIStainless steel lined PTFE corrosion-resistant magnetic flap level gaugeTechnical parameters
1Measurement range: Side mounted0-200mm、0-18000mmTop mounted:0 - 200mm、0 - 6000mm
Please specify the requirements for exceeding the above data.
2Measurement accuracy:±10mm
3Medium density:≥0.5g/cm3
4Work pressure:1.0,1.6,2.5,4.0MPa
5Working temperature:A=80℃,B=120℃,C=300℃
6Medium viscosity:≤0.4Pa. SUnder medium conditions,LHeating jacket should be selected for media with high viscosity or low temperature that are prone to crystallization
7Measurement of boundary specific gravity difference:≥0.15g/cm3
8Factory connection flange size:DN20P N2.5(metric pipe)
9The connecting flange is made by the Ministry of Chemical Industry1998Published annuallyHG20592-20635-97Flange standard. If other flange standards are used, please indicate them when placing an order. Distribution shape of flange connection holes: square.
4Stainless steel lined PTFE corrosion-resistant magnetic flap level gaugemanufacturerinstallation diagram
5Stainless steel lined PTFE corrosion-resistant magnetic flap level gaugemanufacturerModel Selection Table
type |
model |
Scope and Application |
Ordinary side mounted type |
SC-UHZ-P |
Ordinary float level gauge is a type of on-site display instrument widely used in industries such as petroleum, chemical, power, light industry, and environmental protection,Continuous display of liquid level in open or pressurized containers. |
Top mounted type |
SC-UHZ-D |
Suitable for various underground fluid storage tanks, it can display liquid level on the ground. Not suitable for working environments with strong vibrations and strong magnetism (working pressure ≤1.6MPaMeasurement range ≤2m). |
4-20mARemote transmission type |
SC-UHZ-C |
Suitable for on-site observation that is inconvenient and requires ground observation or even remote transmission output to the control room for observation, sound and light alarms, and control pump shutdown |
Equipped with alarm switch |
SC-UHZ-K |
Equipped with upper and lower limit (high and low position) alarm switches, with switch output, generally used for sound and light alarms or controlling the opening and closing of pump valves. |
Anticorrosive type |
SC-UHZ-F |
Especially suitable for liquid level measurement indicators with corrosiveness and toxicity (working pressure ≤1.6MPaMeasurement range ≤2m). |
High temperature type and atmospheric pressure type |
SC-UHZ-T |
Suitable for temperature150℃-450℃, process pressure0-2.5Mpa(2.5-4MPaMeasure the liquid level of the liquid medium in a sealed container under medium pressure. |
High pressure type, room temperature type |
SC-UHZ-Y |
Suitable for temperatures of100Below ℃(100-150℃ belongs to medium temperature), process pressure4Mpa-10MPa(10-20MPaMeasure the liquid level of the liquid medium in a specially customized sealed container. |
High temperature and high pressure type |
SC-UHZ-H |
Suitable for temperatures above200℃, process pressure higher than10Mpa(20MpaMeasure the liquid level of the liquid medium in a sealed container. |
Steam jacket heat tracing |
SC-UHZ-Q |
Suitable for measuring liquid media with high viscosity, high or low temperature (this instrument requires the use of a heat tracing device). It is also a common measure |
Electric heating and heat tracing |
SC-UHZ-V |
The electric heating magnetic flap level gauge is installed with an electric mixing heat source and asbestos insulation layer outside the main body of the base type, which can maintain the temperature of the liquid inside the main body75Around ℃ to allow the liquid to flow normally |
Vacuum jacket insulation |
SC-UHZ-Z |
It is a rare measure to add a vacuum cylinder outside the main tube of the liquid level gauge to insulate the measured medium from the outside. |
Thermal insulation cotton for antifreeze and insulation |
SC-UHZ-M |
Using insulation cotton for insulation, it is suitable for situations where slight low temperatures require anti freezing insulation. Belonging to common insulation measures |
Explosion proof type |
SC-UHZ-B |
Suitable for situations where remote transmission of electrical signals is required in flammable and explosive environments, this instrument is equipped with4mA~20mAElectronic devices such as liquid level transmitters for current signals or upper and lower limit alarm settings. |
Note: If there are comprehensive type requirements, they can be combined into a new model, such as a high temperature and high pressure alarm switch dosing device magnetic flap level gauge, then the model isSC-UHZ-HKFor specific models, please refer to the selection table in the selection manual.
With the arrival of the hot summer season, many on-site reports of magnetic flap level gauge malfunctions have been concentrated. However, according to the dispatch of personnel to the site and telephone communication, it was found that many malfunctions, even so-called“quality problem”It is all caused by human factors, but as a manufacturer, we cannot shift the blame just because it is not our own responsibility when problems first arise. But we must reiterate a few points to note before and during the installation of the magnetic flap column level gauge.
1、Generally, when transporting magnetic flap level gauges, they are packed in wooden boxes with internal clamps. However, even with a good transportation partner, they cannot guarantee perfect and undamaged transportation. Therefore, before opening the box, it is necessary to check whether the wooden box is intact. If there is any damage, please contact the manufacturer or be careful when opening the box to avoid accidentally damaging the level gauge that was not originally damaged, such as scratching the panel, because the panel is most susceptible to damage from hammers or other hard tools during the opening process.
2At the installation site, try not to repeatedly and violently hit or drop the liquid level gauge, which may cause damage to the internal float or other parts.
3Due to the vibration and movement of objects during transportation, it is recommended to use the factory matching bolts before fixing them“bullet-shaped”The magnet runs the flipping column inside the flipping plate from head to tail to ensure the consistency of magnetic flipping.
4、When debugging, the upper inlet valve should be opened first, and then the lower valve should be slowly opened to allow the medium to enter the main pipe smoothly (during operation, the medium should avoid rapid impact on the float, causing the float to fluctuate dramatically and affecting the display accuracy). Observe whether the magnetic red and white balls flip normally, then close the lower inlet valve, open the drain valve, and let the liquid level in the main pipe decrease. Operate this method three times, and if it is normal, it can be put into operation (except for corrosive and other special liquids)
5The installation position of the magnetic flap level gauge should avoid or be far away from the inlet and outlet of the material medium to avoid rapid changes in the local area of the material fluid, which may affect the accuracy of the level measurement
6The installation of the magnetic flap level gauge must be vertical to ensure that the magnetic float can move freely up and down inside the main tube.
7、For special materials, such asPPtexture of material. Attention should also be paid to those that are prone to cracking due to excessive installation force. If the flatness of the upper and lower flanges of the tank body is not flat or uneven, then when the upper and lower flanges are connected, tightening the bolts vigorously will cause cracks or even fractures in the lower leg of the liquid level gauge flange and the steel pipe of the liquid level gauge. This is the latest customer report of water leakage in this area. (Before leaving the factory, it undergoes pressure and water testing, and occasionally this leakage is caused by the customer's reckless actions.)
8The magnetic flap level gauge cylinder should not have any magnetic conductors near it, otherwise it will directly affect the normal operation of the level gauge.
9There should be no solid impurities or magnetic impurities entering the cylinder of the magnetic flap level gauge to avoid jamming the float and reducing buoyancy.
10According to the condition of the medium, the drain valve can be opened regularly to clean the main pipe and remove the sediment inside the pipe.
11、When equipped with remote transmission instruments, the following measures should be taken: The sensing surface on the remote transmission supporting instrument should face and be closely attached to the main pipe; The remote transmission supporting instruments should be tightly attached to the main pipe of the liquid level gauge and fixed with stainless steel clamps (iron is prohibited); The zero position of the remote transmission supporting instrument should be on the same horizontal line as the zero position indication of the liquid level gauge; The connection between remote transmission supporting instruments and display instruments or industrial control computers should be laid separately through protective pipes or with shielded two core cables; After the wiring holes of the junction box are laid, it is required to be well sealed to prevent rainwater, moisture, and other factors from entering and causing the remote transmission supporting instruments to malfunction. The junction box should be promptly covered after maintenance or debugging is completed. The magnetic flap level gauge consists of a body, flap box (composed of red and white dual color magnetic flap plates), float, flange cover, and other components
What parameters are required to purchase a magnetic flap level gauge
Many dealers are looking to purchase Huai'an SanchangMagnetic flap level gaugeWhen it comes to magnetic flap level gauges, there are often situations where parameters are missing. Generally, products are customized according to customer requirements, so it is necessary to know the accurate parameters of the magnetic flap level gauge. This article briefly introduces the ordering instructions for magnetic flap level gauges.
1Model: The specific model can be found on our company's website
2Medium temperature: What is the lowest and highest temperature of the measured liquid
3Medium density: If you don't know the density, you can tell us the name of the medium. When mixing liquids, you need to know which types of liquids they are composed of.
4What is the highest level of work pressure
5Measurement range: also known as nominal length, which is the distance between the centers of two flanges, or to check the scale scale of the product that has been used.
6Flange standard: The nominal diameter of the flange, which flange is the most commonly usedDN20perhapsDN25
7Liquid handling material: If you don't know which material to use, you can consult us
7Special requirements: Please specify in detail before placing an order, such as whether remote transmission, insulation jacket, etc. are required.
We will continue to uphold“Innovative, pragmatic, and high-quality service”Adhere to the corporate spirit and uphold it“Build products with character, survive with quality, develop new products with technology, and rely on reputation Seeking development”The quality policy and always keep it in mind“Sincerely facing every user”The foundation of this enterprise's survival is to constantly pursue high-tech and high-quality products, work hand in hand with customers, and establish a shared and win-win relationship.
Huai'an Sanchang Instrument is breaking out of the world with a strong development momentum, an innovative spirit that never stops, and the title of Chinese brand.
If you are not familiar with the product and do not know how to select it, you can check it outSelection Manual for Magnetic Flip Plate Liquid Level GaugeIf you still don't understand the detailed version, you can directly contact our sales consultant by phone.