SulfurChrome ™ GC Total Sulfur Analyzer
Beijing Leshi Technology provides a complete range of high-quality systems suitable for gas and liquid measurement, solving process analysis and measu
Product details

Rapid investment return
• Optimize deodorization process
• Ensure compliance with the contract
• Automatic sealed oil delivery verification
• Avoid contamination of pipeline "locking ports"
Measurement certainty
Multiple streams with up to 8 channels
A single calibration gas for all sulfur species
• Bipolar response at ppb to% levels
• Performance is not affected by changes in hydrocarbons, process equipment, or mixing

Provide services based on customer needs. Differentiated sulfur measurement for precise process analysis. Do you need to monitor the concentration of odorants in hydrocarbon gas? This application requires highly sensitive detection and measurement of individual sulfur components. The application of transfer pipes in some natural gas pipelines also requires detailed reports on the concentration of sulfur components. GALVANIC's SULFURCHROME online chromatography instrument enables easy and real-time measurement of all chemical components containing sulfur up to a concentration of 5ppb.

硫化氢总硫分析仪

硫化氢总硫分析仪表

SulfurChrome ™ GC product specifications

Performance of Total Sulfur Analyzer:
accuracy
± 2% full range
Repeatability
± 2% full range
sensitivity
± 2% full range
response time

T90: 4~15 minutes, with an average of 6 minutes [specific application]

Method/Technology
Gas chromatography/sulfur chemiluminescence detector
Sulfur measurement
H2 S, COS, CS2 , Sulfides, Disulfides, Disulfides, Thiols, Thiophenes, Total Sulfur, Others
Range
0 ~ 10 mg/l, 0~5 g/l [equimolar response to all sulfur species]
environment
ambient temperature
0 ~ 50°C [32° to 122°F]
relative humidity
0~95% non condensing
install
indoor
size
711 x 1,016 x 406 [28” x 40” x 16”]
weight
57 kg. [125 lbs.]
Shell
Painted steel
Basic conditions:
Power/Consumption
100~240 VAC, 600 watts
helium
10 cc/min, 4 bar [60 psi]
hydrogen
80 cc/min, 1 bar [15 psi]
Calibration gas
H2S in nitrogen [for all sulfur species]
Vacuum pump
115 VAC, 6 Amp consumption
Communication:
Analog output
4 x 4-20mA output (cyclic or automatic)
Analog input

3 x 4-20mA input [RTD, 4-20mA, transducer]

Modbus

TCP/IP, RS232, Or RS485

Digital input
4 Discrete inputs
Digital output
4 x SPDT relays
interface
Color LCD display and expandable keyboard
PC GUI
Ethernet access
CEC / NEC
Class I Div. 2 Groups BCD T3 [Purged]
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!