Super constant temperature oil bath pot (with internal and external circulation)
High precision super constant temperature oil bath pot (with internal and external circulation) is widely used in distillation, drying, concentration,
Product details

1High precision super constant temperature oil bath potIntroduction:

HH-W602High precision super constant temperature circulating oil bath potYes, it isOn the basis of the constant temperature oil bath pot, internal and external circulation functions have been added, greatly improving the uneven oil temperature at various points inside the oil bath pot in the past. The instrument is equipped with an external circulation interface, which can be connected to experimental equipment outside the instrument, such as reaction vessels.Widely used in distillation, drying, concentration, and impregnation of chemical or biological products. It is an ideal tool for laboratory technicians in universities, environmental protection, scientific research, health, epidemic prevention, petroleum, metallurgy, chemical, medical and other units.

IIHigh precision super constant temperature oil bath potTechnical parameters:
1Temperature control range: room temperature-300.0
2Temperature fluctuation: ±0.1
3Temperature uniformity:0.1
4Display resolution:0.1
5Display mode:LCCLCD screen display
6Temperature control method: microcomputerPIDControl,PT100sensor
7Constant temperature timing:1minute-99hour59Minute or normally open
8Cycle timing:1-120Minute or normally open
9Circulating pump flow rate:6L/min, Power40W
10Heating power:2000W
11Inner container size:400×300×180mm
12Opening size:300×265mm
13groove depth180mm
14Power supply:220v 50Hz

IIIHigh precision super constant temperature oil bath potcharacteristic:

1Adopting a microcomputer LCD temperature controller, various working states have Chinese display function, precise temperature control, and simple operation.
2Overtemperature protection, overtemperature buzzer prompt function.
3It has dual functions of internal and external circulation.
4Circulating pump timing function.
5The temperature controller has temperature display and constant temperature timed decreasing display functions.
6Sensor fault code prompt function.
7Display temperature and actual temperature error correction function.
8The heater, fuel tank, and circulation pump are all made of high-quality stainless steel.
9The insulation material inside the box adopts high-quality glass fiber as the insulation material, ensuring that there is no significant temperature rise outside the box when the instrument is used at high temperatures.
4High precision super constant temperature oil bath potusage method:
1Before installing the equipment, the oil bath pot should be placed on a flat workbench for visual inspection: the appearance should be undamaged, the instrument appearance should be intact, the power cord should be undamaged, the plug should be intact, and the power switch should be flexible. Each device's power cord is connected to a single-phase three pole plug, with the electrode above the plug being the grounding wire. Users must use a power socket with a safety grounding when using it.
2Before powering on, add an appropriate amount of thermal oil to the fuel tankIt is advisable to be 5-8cm away from the top cover.
3Setting and use of digital temperature control instruments:
1)Turn on the power switch, the power indicator light is on, turn on the heating switch,The temperature controller lights up, wait for about 20 seconds, the upper row displays the actual temperature inside the box, and the lower row displays the set temperature. Click the function key, the upper row displays sp, and the lower row displays the set temperature. Click △ or ▽ to select the working temperature. Click the function key again, the upper row displays st, and the lower row displays the time needed for heating. Click △ or ▽ to select the constant temperature timing time. If there is no need for timing, set the time to 00.00 to complete the setting. Click the function key again to exit, and the system will run according to the set parameters.
(2) Place the reagent bottle that needs to be heated inside the box (if using external circulation, please connect the circulation tube before heating), turn on the circulation switch, and the oil will circulate inside the box to ensure the uniformity of oil temperature at all points inside the box.
(3) After the experiment is completed, first turn off the loop switch, then set the temperature to 0, turn off the heating switch, and finally turn off the power switch and cut off the power.
5High precision super constant temperature oil bath potmatters needing attention:
1All technical indicators of this series of products have undergone actual operation inspection before leaving the factory. If the user needs to use a self provided thermometer (with certain accuracy) for measurement due to process requirements, the user's thermometer shall prevail. If there is a difference between the displayed value of the temperature control instrument and the thermometer, the user will adjust the displayed temperature and the actual temperature through the internal temperature control instrument.
2When using the super constant temperature oil bath pot, it is necessary to add oil first and then turn on the electricity, and dry burning is strictly prohibited.
3. When using an oil bath pot, reliable grounding is necessary to ensure safe use.
4. If the oil level is lower than the electric heating tube, it is not allowed to use it with electricity to prevent the electric heating tube from bursting and being damaged.
5. The oil level should not be too high to avoid overflowing into the electrical box and damaging components.
6. Regularly check whether the screws of each contact are loose, and if they are loose, tighten them to maintain good contact of each electrical contact.
7. Please wear safety gloves when using to avoid burns.
Note: Can be controlled according to customer requirements