Qingdao Traceability Environmental Protection Equipment Co., Ltd
Home>Products>TC-100W Microwave COD Dissolver
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18553291905
  • Address
    No. 77 Chaoyangshan Road, Huangdao District, Qingdao City
Contact Now
TC-100W Microwave COD Dissolver
Product Description: TC-100W (CODCr, TP, TN) Microwave COD Dissolver. It can quickly and efficiently determine the chemical oxygen demand (CODCr), tot
Product details
TC-100W microwave COD digester | microwave digester | fast COD digester
COD微波消解仪

1、 Product Description:

TC-100WType(CODCrTPTN)MicrowaveCODDissolver. Can measure the chemical oxygen demand in various surface water, domestic sewage, and industrial wastewater(CODCr)Total phosphorus(TP)Total nitrogen(TN)Perform rapid and efficient digestion determination. Guang Fan is applicable to the identification and management of water quality by environmental protection departments, water resources management departments, and public health departments at all levels.
Microwave sealingCODThe digester is a new type of device specifically designed to monitor the chemical oxygen demand of various types of wastewater, domestic sewage, and surface water in China.

in comparison withCODBiao Zun reflux method, microwave sealed digestionCODThe required reagents for the method are significantly reduced, the resistance to chloride ion interference is strong, and the digestion time is only10Minutes can be used as an equivalent method to achieve the goals of saving time, energy, water, and efficiency.

The instrument adopts testing methods and biao zhun(GB118891191589)Vocabulary of Water Quality (Part 1)37Partial analysis methods, "Water and Wastewater Monitoring and Analysis Methods" (Third Edition)CODcrThe potassium dichromate method is basically the same as the potassium persulfate digestion spectrophotometric method for total phosphorus and total nitrogen.

2、 Technical features:
1Microwave sealingCODThe digester uses a frequency of2450MHZElectromagnetic waves(Called microwave)Energy is used to heat the reaction solution, and under the action of high-frequency microwave energy, the molecules of the reaction solution undergo high-speed frictional motion, causing their temperature to rise rapidly. In addition, a sealed digestion method is used to rapidly increase the pressure inside the digestion tank to about203kPaTherefore, not only does it shorten the digestion time, but it can also inhibit the oxidation of chloride ions to chlorine gas by potassium dichromate. If an appropriate amount of mercury sulfate is added as a masking agent, it can achieve the elimination of high chlorine waterCODdetermination. The entire digestion process does not require cooling water, reducing the hassle of installing cold water pipes and stopping water supply.
2
Under the control of a microcomputer, a certain amount of potassium dichromate is used to oxidize the reducing substances in the water sample in a strong acidic solution. Excess potassium dichromate is titrated with ammonium ferrous sulfate using ferrous sulfate as an indicatorCODCrValue. Colorimetric method can also be used at the wavelength600nmDirectly measure the concentration of trivalent chromium in the reaction solution to obtain the water sampleCODCrValue.
3The instrument also uses a closed (sealed) state for digestion. One of its advantages is that it can create a certain pressure inside the tank to quickly increase the temperature of the reaction system and shorten the digestion time; Secondly, inCODcrIn the analysis, the effective inhibition of the oxidation of chloride ions to chlorine gas by potassium dichromate can be combined with the addition of an appropriate amount of mercury sulfate as a masking agent to determine the chemical oxygen demand of high chlorine wastewater.
4Sealed digestion, overpressure protection, safe and reliable, with a buzzer indicating completion of digestion.

5Can dissolve various substances, including chemical oxygen demand(CODcr)Total phosphorus(TP)Total nitrogen(TN); Used for digestionCODcrWhen using sealed digestion, it can improve the ability to resist chloride ion interference and can be used for measurementCODcrValue greater than50mg/LThe chloride ion content is as high as10000mg/LThe water sample.

3、 Technical features:

project

parameter

Dissolution range:

CODcr:5—2500mg/L TP:0.01—0.6mg/L TN:0.05---4mg/L

CODcrAnti chloride ion interference ability:

≤10000mg/L


Precision:

CODcrValue in80—150mg/LTime: Indoor relative bias≤4.3%Relative deviation between rooms≤5.0%

TPTNCan meet the needs of biao zhun(GB11889-11915-89)Vocabulary of Water Quality (Part 1)3-7Requirements for Partial Analysis and Analytical Methods


Accuracy:

CODcrCompared to the classical reflux method, the correlation coefficientr0.999

TPTNComparison with biao zhun method, correlation coefficientr0.999

Sample quantity (per batch):

Biao zhun configuration6One, the highest achievable12A sample (customized)

Dissolving time:

5—16min

Microwave operating frequency:

2450MHz

Rated input power:

1300W(The biggest) A.C(220±22)V (50±1)Hz

Microwave output power:

800W

External dimensions:

485mm×390mm×280mm

Applicable environmental conditions

Environmental temperature and humidity:5—40≤90%RHAtmospheric pressure range:86Kpa—106Kpa

4、 Main configuration:
1Host One unit
2Dissolving tank Six
3One power cord
4Instruction manual a copy
5Certificate of Conformity a copy
6Warranty card a copy


TC-100W微波消解器
TC-100W微波消解器显示屏幕TC-100W微波消解器消解罐


New Product Introduction
1、 Product Description:

COD microwave digestion instrument is a pretreatment technology that combines high-pressure digestion and microwave rapid heating. After the mixture of water sample and acid absorbs microwave energy, the oxidation reaction activity of the acid increases, causing rapid chemical reactions of organic matter and other substances in the sample, in order to achieve the goal of rapid determination of water samples. The TC-100W COD microwave digestion instrument is designed based on relevant national standards and experimental foundations to quickly determine chemical oxygen consumption. It can be widely used for the determination of chemical oxygen consumption in surface water, groundwater, domestic sewage, and industrial wastewater.
2、 Technical features:
1. The experimental methods for TC-100W COD microwave digestion instrument are based on the "HJ/T 91 Technical Specifications for Monitoring Surface Water and Wastewater"HJ/T 164Technical Specifications for Groundwater Environmental Monitoring, Methods for Monitoring and Analyzing Water and Wastewater, etc

2. The TC-100W COD microwave digestion instrument uses 2450MHz electromagnetic waves as heating energy to generate high heat through high-speed wheel oscillation friction between water molecules, thereby achieving rapid heating and shortening digestion time.

3. The TC-100W COD microwave digestion instrument uses a PTFE sealed digestion tank for digestion,The high temperature and high pressure during the digestion process can shorten the digestion time and suppress the influence of chloride ions on the reaction results; Adding an appropriate amount of mercuric sulfate can be used to measure the chemical oxygen consumption of high chlorine wastewater.

4. There is no need for cooling water during the digestion process, and there is a buzzing prompt after digestion is completed, which is convenient for experimental operation.

5. After digestion, the chemical oxygen consumption can be determined by potassium dichromate titration or by spectrophotometric colorimetry.

6. Can complete the digestion of chemical oxygen demand in water samples.

3、 Technical features:

1. Dissolving project: Chemical Oxygen Demand (COD): 5~3000mg/L (chlorine interference resistance ≤ 12000mg/L) Total phosphorus (TP): 0.01-0.6mg/L Total nitrogen (TN): 0.05-7mg/L

2. Dissolving quantity: 6 (standard), maximum can dissolve 12

3. Dissolving time: 0-99min99s (customizable)

4. Dissolving volume: 50mL * 6 pieces (standard)

5. Material of digestion tank: polytetrafluoroethylene

6. Relative bias: ≤ 5%

7. Input power: COD:1300W,TP、TN:850W

9. Output power: 800W

9. Size and weight: External dimensions: 275mm × 460mm × 400mm Internal dimensions: 180mm × 315mm × 328mm 13Kg

4、 Main configuration:

One digestion instrument, six digestion tanks, one power cord, one instruction manual, one certificate of conformity, and one warranty card

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!