1、 Instrument Introduction
The TC-301 COD ammonia nitrogen total phosphorus detector is developed by our company in accordance with the national standards "HJ/T399-2007 Determination of Chemical Oxygen Demand in Water Quality - Rapid Digestion spectrophotometric method" and "HJ 535-2009 Determination of Ammonia Nitrogen in Water Quality - Nessler's reagent spectrophotometric method"GB/T 11893-1989 Water quality - Determination of total phosphorus - Ammonium molybdate spectrophotometric methodAnd a COD ammonia nitrogen total phosphorus detector designed for industry demand research and development, which has PID automatic adjustment technology and functions such as curve self calibration and automatic zero adjustment, enhancing the accuracy and stability of the instrument; Widely used in COD testing, ammonia nitrogen testing, and total phosphorus testing in various industries such as laboratories, sewage treatment plants, universities, environmental monitoring departments, and research institutions.
2、 Main features
1. The measurement system adopts advanced optical systems and cold light sources, with high measurement accuracy, small drift, and good stability;
2. Adopting a 13:7 series high brightness large screen LCD display, with a Chinese operating system for easy operation;
3. The digestion system is independent of the measurement system and does not interfere with each other;
4. The digestion system adopts PID regulation technology, which has high temperature control performance, good stability, and saves energy consumption;
5. The instrument has an automatic calibration function, which can automatically adjust the calibration curve and improve measurement accuracy;
6. The use of spectrophotometry combined with specialized reagents greatly reduces operation time and workload;
7. Built in large capacity storage space, capable of storing 100 curves and 30000 measurement results;
8. The instrument comes with a computer connection interface, which can upload experimental data or connect to a printer to print data;
9. Optional external thermal printer for printing experimental data;
10. The instrument is equipped with dedicated data recording and processing software, which facilitates the storage, processing, and analysis of experimental data;
3、 Technical parameters
① COD parameters:
1. Determination method: spectrophotometric rapid catalytic method
2. Range: 5~150mg/L, 100~5000 mg/L (segmented measurement, expandable);
3. Measurement error: ≤ ±5 %
4. Range of photometric measurement: 0-2A
5. Wavelength accuracy: ± 1 nm;
6. Linear photometric measurement: ± 0.002 A;
7. Repeatability of photometric measurement: ± 0.005 A;
8. Accuracy of photometric measurement: ± 0.005 A;
9. Dissolution temperature: 165 ± 1 ℃;
10. Dissolution time: 15 minutes;
11. Measurement time: 30 minutes for simultaneous measurement of 9/12/25 water samples;
12. Anti chlorine interference: [CL-] <1000mg/ L; [CL -]<4000mg/L (optional);
13. Temperature indication error: < ±1.5℃;
14. Uniformity of temperature field: ≤ 1.5℃;
15. Error in digestion time indication: ≤ ±3%;
16. Curve parameters: 100 measurement curve parameters can be set;
17. Record storage: It can store 30000 measurement results.
18. Printing: Portable printer, directly printing measurement results (optional);
19. Environmental temperature: (5~40) ℃; Environmental humidity: relative humidity<85% (no condensation);
20. Working power supply: AC220V ± 10%/50Hz; DC power supply can work continuously for 50 hours.
② Ammonia nitrogen parameters:
1. Determination method: Nessler's reagent spectrophotometric method
2. Range: 0.02-25-50mg/L (segmented measurement, expandable);
3. Measurement error: ≤ ±5 %
4. Range of photometric measurement: 0-2A
5. Wavelength accuracy: ± 1 nm;
6. Linear photometric measurement: ± 0.002 A;
7. Repeatability of photometric measurement: ± 0.005 A;
8. Accuracy of photometric measurement: ± 0.005 A;
9. Curve parameters: 100 measurement curve parameters can be set;
10. Calibration: Built in automatic calibration curve function;
11. Built in high-precision micro electronic clock with a monthly error of less than 8 seconds;
12. Record storage: store 30000 experimental results, power off data protection;
13. Printing: Optional external micro printer for direct printing of data
14. Communication method: RS232, Can be connected to a computer RS232/USB interface to upload experimental results;
15. Display: 250 * 130 LCD blue backlit display, fully Chinese operation interface;
16. Environmental temperature: (5~40) ℃; Environmental humidity: relative humidity<85% (no condensation);
17. Working power supply: AC220V ± 10%/50Hz, DC power supply can work continuously for 50 hours.
③ Total phosphorus parameters:
1. Determination method: Ammonium molybdate spectrophotometric method
2. Measurement range: 0.01~24mg/L (segmented measurement, expandable)
3. Measurement error: ≤ ±5 %
4. Range of photometric measurement: 0-2A
5. Wavelength accuracy: ± 1 nm;
6. Linear photometric measurement: ± 0.002 A;
7. Repeatability of photometric measurement: ± 0.005 A;
8. Accuracy of photometric measurement: ± 0.005 A;
9. Dissolution temperature and time: 120 ± 1 ℃; 30min
10. Measurement time: Dissolve 9/12/25 water samples simultaneously within 30 minutes;
11. Temperature indication error: < ±1.5℃;
12. Uniformity of temperature field: ≤ 1.5℃;
13. Error in digestion time indication: ≤ ±3%;
14. Curve parameters: 100 measurement curve parameters can be set;
15. Record storage: capable of storing 30000 measurement results;
16. Printing: Portable printer, directly printing measurement results (optional);
17. Environmental temperature: (5~40) ℃; Environmental humidity: relative humidity<85% (no condensation);
18. Working power supply: AC220V ± 10%/50Hz; DC power supply can work continuously for 50 hours.
4、 Product configuration
Serial Number |
name |
quantity |
Serial Number |
name |
quantity |
1 |
host |
1 unit |
9 |
Ammonia nitrogen reagent |
1 set |
2 |
Dissolver (standard configuration)12Hole) |
1 unit |
10 |
Total phosphorus reagent |
1 set |
3 |
Sealed digestion tube |
12 pieces |
11 |
power line |
2 pieces |
4 |
Dissolve the protective cover |
1 pair |
12 |
data line |
1 piece |
5 |
test tube rack |
1 set |
13 |
Data processing software |
1 set |
6 |
Colorimetric dish rack |
1 set |
14 |
certificate of conformity |
1 copy |
7 |
Colorimetric dish |
1 set |
15 |
warranty card |
1 copy |
8 |
COD reagent |
1 set |
16 |
instructions |
1 copy |