Sanwei Science has launched a new temperature controlled Hastelloy alloy pump and a temperature controlled Hastelloy high-pressure metering pumpTemperature controlled Hastelloy high-pressure constant current pumpThe temperature control is a new generation of ultra miniature temperature limiting instrument, using a microcontroller as the main control chip. This temperature controller has the advantages of simple operation, small on-off temperature difference, high adjustment accuracy, and long service life. Three scientific temperature controlled high-pressure infusion pumps are widely used in fields such as chemical feeding, reactant addition, catalyst addition, foaming extrusion process, new energy research, and supporting equipment for catalytic refining kettle reactions.
TH1010Characteristics of temperature controlled Hastelloy pump:
Partition temperature control
Intelligent digital display control of pump head temperature, with a temperature control accuracy of ± 1 ℃
Pipeline temperature control, with consistent liquid circuit temperature in the inlet, outlet, and pump chamber areas
Built in insulation structure to achieve stable temperature controlled microenvironment
Two options: integrated design and split design, with flexible configuration
Accurate delivery of hardware functions
Function of conveying by volume and weight
Client calibration and multi-point traffic curve calibration techniques
Cam curve compensation and flow pulse electronic suppression technology
Online display of pressure flow curve and dynamic monitoring
Software Communication System Integration
One to many control, many to many control
Multiple communication ports: RS232/485/422、USB、 Wired/wireless network
Multi communication protocol:Modbus、ProfibusDP、Profinet
SCADA/DCS/PLCControl system integration and configuration application
Analog input control, on-off control
TH1010Temperature controlled typeHastelloy pumpParameters:
Serial number |
describe |
index |
1 |
Infusion method |
Dual plunger parallel mode, floating plunger design |
2 |
Temperature range |
Room temperature -100 ℃ |
3 |
Temperature measurement accuracy |
±1℃ |
4 |
Flow range |
0.01-100.00/min |
5 |
increment |
0.01ml/min |
6 |
Traffic accuracy |
± 0.5% |
7 |
Traffic repeatability |
≤ 0.1% |
8 |
Pressure range |
≤ 10Mpa |
9 |
pressure fluctuation |
≤ 0.2Mpa |
10 |
Flow path material |
Hastelloy, ruby PTFE、PCTFE、 ceramics |
11 |
Communication function |
RS232,RS485; Modbus RTU communication protocol; Switching input |
12 |
Display parameters |
256 * 64 dot LCD display, self luminous display screen |
13 |
Power Supply |
85 ~ 264VAC,50Hz |